BLUERIDGE / AIR-SOURCE HEAT PUMP

BHP17L30P-**A

BHP17 SERIES · BHP17 Series · BHP17L SERIES · BHP17L Series · source records, page 5

139 published source records · source checked Sep 21, 2026

SEER2 range15.4–16.2BTU/Wh
HSPF2 range7.8–8.6BTU/Wh
Cooling capacity28,200–30,000BTU/h

Each efficiency range summarizes published EPA records for BHP17L30P-**A. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 139 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.4–16.2139 / 139
EER2 · BTU/Wh12.2–13.5139 / 139
HSPF2 · BTU/Wh7.8–8.6139 / 139
Cooling capacity · BTU/h28,200–30,000139 / 139
Heating capacity at 47°F / 8.3°C · BTU/h26,600–30,000139 / 139
Heating capacity at 17°F / −8.3°C · BTU/h17,400–19,600139 / 139
Heating capacity at 5°F / −15°C · BTU/h13,200–15,400139 / 139
COP at 5°F / −15°C1.98–2.34139 / 139
Equipment / loop typeHP - Split System139 / 139
Refrigerant / source-reported GWPR-410A (GWP:2088)139 / 139
Compressor stagingSingle stage139 / 139
Connected capabilityNo139 / 139

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
BC1P36A+TDR+TXV+ furnace: BG961UH070BE12AHRI reference: 21032540915.608.10143002.26EPA 2455681
BC4X30B+TDR+ furnace: BG802UH090BV16AHRI reference: 21044128715.608.10145002.18EPA 2456389
BC4X36B+TDR+ furnace: BG961UH070BE12AHRI reference: 21044130115.608.10143002.26EPA 2456485
BC4X30B+TDR+ furnace: BG921UH045BE12AHRI reference: 21044128315.608.00144002.20EPA 2456486
BC1P36B+TDR+TXV+ furnace: BG961UH045BE12AHRI reference: 21044126515.608.10146002.26EPA 2456498
BC4X30B+TDR+ furnace: BG921UH070BE12AHRI reference: 21044128415.608.00144002.20EPA 2457322
BC4X36B+TDR+ furnace: BG961UH045BE12AHRI reference: 21044130015.608.10146002.26EPA 2457509
BC1P30B+TDR+TXV+ furnace: BG921UH070BE12AHRI reference: 21044125415.608.00144002.20EPA 2457516
BC1P36B+TDR+TXV+ furnace: BG961UH070BE12AHRI reference: 21044126615.608.10143002.26EPA 2457526
BC1P30B+TDR+TXV+ furnace: BG802UH090BV16AHRI reference: 21044125715.608.10145002.18EPA 2458586
BC4X30A+TDR+ furnace: BG802UH070AV12AHRI reference: 21044127715.608.00145002.20EPA 2458849
BC4X30A+TDR+ furnace: BG802UH070AE12AHRI reference: 21044127415.608.00144002.20EPA 2458871
BC4X30A+TDR+ furnace: BG801UH070AE12AHRI reference: 21044127615.608.00144002.20EPA 2458884
BC1P30B+TDR+TXV+ furnace: BG921UH045BE12AHRI reference: 21044125315.608.00144002.20EPA 2459374
BC1P30A+TDR+TXV+ furnace: BG802UH070AV12AHRI reference: 21032536815.608.00145002.20EPA 2460624
BC1P30A+TDR+TXV+ furnace: BG801UH070AE12AHRI reference: 21032536715.608.00144002.20EPA 2460850
BC1P30A+TDR+TXV+ furnace: BG921UH070BE12AHRI reference: 21032537615.608.00144002.20EPA 2461857
BC1P30A+TDR+TXV+ furnace: BG921UH045BE12AHRI reference: 21032537415.608.00144002.20EPA 2461886
BC1P30A+TDR+TXV+ furnace: BG802UH090BV16AHRI reference: 21032538715.608.10145002.18EPA 2462394
BH1P36C*+TDR+TXV+ furnace: BG921UH110CE20AHRI reference: 21173613715.608.50148002.24EPA 2464090

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.