BLUERIDGE / AIR-SOURCE HEAT PUMP

BHP17L30P-**A

BHP17 SERIES · BHP17 Series · BHP17L SERIES · BHP17L Series · source records, page 4

139 published source records · source checked Sep 21, 2026

SEER2 range15.4–16.2BTU/Wh
HSPF2 range7.8–8.6BTU/Wh
Cooling capacity28,200–30,000BTU/h

Each efficiency range summarizes published EPA records for BHP17L30P-**A. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 139 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.4–16.2139 / 139
EER2 · BTU/Wh12.2–13.5139 / 139
HSPF2 · BTU/Wh7.8–8.6139 / 139
Cooling capacity · BTU/h28,200–30,000139 / 139
Heating capacity at 47°F / 8.3°C · BTU/h26,600–30,000139 / 139
Heating capacity at 17°F / −8.3°C · BTU/h17,400–19,600139 / 139
Heating capacity at 5°F / −15°C · BTU/h13,200–15,400139 / 139
COP at 5°F / −15°C1.98–2.34139 / 139
Equipment / loop typeHP - Split System139 / 139
Refrigerant / source-reported GWPR-410A (GWP:2088)139 / 139
Compressor stagingSingle stage139 / 139
Connected capabilityNo139 / 139

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
BC1P36B+TDR+TXV+ furnace: BG921UH045BE12AHRI reference: 21044126315.808.10143002.26EPA 2459447
BC1P30B+TDR+TXV+ furnace: BG802UH090BE12AHRI reference: 21044124815.808.10143002.24EPA 2459683
BC1P30A+TDR+TXV+ furnace: BG801UH045AE12AHRI reference: 21032536515.808.00141002.20EPA 2461432
BC1P30A+TDR+TXV+ furnace: BG802UH090BE12AHRI reference: 21032538215.808.10143002.24EPA 2461647
BH1P36C*+TDR+TXV+ furnace: BG921UH110CE16AHRI reference: 21173612215.808.30147002.24EPA 2462796
BH1P36C*+TDR+TXV+ furnace: BG801UH090CE20AHRI reference: 21173606015.808.50148002.26EPA 2469293
BD4X-42B+TDR+ furnace: BG802DF070AE12AHRI reference: 21326551015.808.60151002.32EPA 2839905
BC730HBT-0*+TDR+ furnace: BG921UH045BE12AHRI reference: 21471338815.807.80136002.10EPA 3486944
BC736HCT-0*+TDR+ furnace: BG801UH090CE20AHRI reference: 21471339315.808.50148002.26EPA 3486951
BC730CAT-0*+TDR+ furnace: BG801UH045AE12AHRI reference: 21471340815.808.00141002.20EPA 3486960
BC730CBT-0*+TDR+ furnace: BG802UH090BE12AHRI reference: 21471341115.808.10143002.24EPA 3486975
BC730CBT-0*+TDR+ furnace: BG801UH070BE12AHRI reference: 21471341315.808.00144002.22EPA 3486977
BC736CAT-0*+TDR+ furnace: BG802UH070AV12AHRI reference: 21471342415.808.10144002.26EPA 3487018
BC742DBT-0*+TDR+ furnace: BG802DF070AE12AHRI reference: 21471340315.808.60151002.32EPA 3487085
BC736CBT-0*+TDR+ furnace: BG921UH045BE12AHRI reference: 21471343015.808.10143002.26EPA 3487296
BC736HCT-0*+TDR+ furnace: BG921UH110CE16AHRI reference: 21471339715.808.30147002.24EPA 3491723
BAH7V36PT-0*AHRI reference: 21486614615.808.10134002.16EPA 3553925
BAH7E30PT-0*AHRI reference: 21486615915.807.80137002.14EPA 3553927
BC1P30A+TDR+TXV+ furnace: BG802UH070AE12AHRI reference: 21032536315.608.00144002.20EPA 2455349
BC1P36A+TDR+TXV+ furnace: BG961UH045BE12AHRI reference: 21032540715.608.10146002.26EPA 2455589

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →