BLUERIDGE / AIR-SOURCE HEAT PUMP

BHP17L24P-**A

BHP17 SERIES · BHP17 Series · BHP17L SERIES · BHP17L Series · source records, page 2

143 published source records · source checked Sep 21, 2026

SEER2 range15.4–17BTU/Wh
HSPF2 range7.8–8.2BTU/Wh
Cooling capacity22,600–24,000BTU/h

Each efficiency range summarizes published EPA records for BHP17L24P-**A. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 143 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.4–17143 / 143
EER2 · BTU/Wh12.5–14143 / 143
HSPF2 · BTU/Wh7.8–8.2143 / 143
Cooling capacity · BTU/h22,600–24,000143 / 143
Heating capacity at 47°F / 8.3°C · BTU/h21,000–22,600143 / 143
Heating capacity at 17°F / −8.3°C · BTU/h13,400–14,700143 / 143
Heating capacity at 5°F / −15°C · BTU/h10,200–11,500143 / 143
COP at 5°F / −15°C2–2.14143 / 143
Equipment / loop typeHP - Split System143 / 143
Refrigerant / source-reported GWPR-410A (GWP:2088)143 / 143
Compressor stagingSingle stage143 / 143
Connected capabilityNo143 / 143

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
BH1P24A*+TDR+TXV+ furnace: BG801UH070AE12AHRI reference: 21173497816.407.80104002.06EPA 2471834
BC4X30B+TDR+ furnace: BG802UH090BE16AHRI reference: 21044123816.408.00104002.06EPA 2471912
BC4X24B+TDR+ furnace: BG801UH090BE16AHRI reference: 21044122516.407.80104002.08EPA 2472135
BC4X30A+TDR+ furnace: BG802UH070AV12AHRI reference: 21044123516.407.80104002.04EPA 2472140
BC4X30B+TDR+ furnace: BG801UH070BE12AHRI reference: 21044124016.407.80104002.06EPA 2472152
BC1P30A+TDR+TXV+ furnace: BG802UH090BE16AHRI reference: 21032551416.408.00104002.06EPA 2472187
BC1P30A+TDR+TXV+ furnace: BG801UH070BE12AHRI reference: 21032549816.407.80104002.06EPA 2472268
BC1P24A+TDR+TXV+ furnace: BG801UH090BE16AHRI reference: 21032548416.407.80104002.08EPA 2472269
BC1P24A+TDR+TXV+ furnace: BG801UH070BE12AHRI reference: 21032546916.407.80104002.04EPA 2472277
BC4X24B+TDR+ furnace: BG801UH070BE12AHRI reference: 21044122416.407.80104002.04EPA 2472342
BC1P30A+TDR+TXV+ furnace: BG802UH070AV12AHRI reference: 21032549616.407.80104002.04EPA 2472393
BC4X24B+TDR+ furnace: BG802UH090BE16AHRI reference: 21044122216.407.80104002.04EPA 2472457
BC1P24B+TDR+TXV+ furnace: BG801UH070BE12AHRI reference: 21044119316.407.80104002.04EPA 2472553
BC1P30B+TDR+TXV+ furnace: BG801UH070BE12AHRI reference: 21044120416.407.80104002.06EPA 2837066
BC1P24B+TDR+TXV+ furnace: BG801UH090BE16AHRI reference: 21044119416.407.80104002.08EPA 2837075
BH1P30B*+TDR+TXV+ furnace: BG802UH090BV16AHRI reference: 21173534316.407.80104002.04EPA 2837347
BC730HAT-0*+TDR+ furnace: BG801UH045AE12AHRI reference: 21471332916.408.00102002.08EPA 3486516
BC730/36DCT-0*+TDR+ furnace: BG96G1DF090CE16AHRI reference: 21471334716.408.20112002.10EPA 3486804
BC724HAT-0*+TDR+ furnace: BG801UH070AE12AHRI reference: 21471332516.407.80104002.06EPA 3486882
BC730CBT-0*+TDR+ furnace: BG801UH070BE12AHRI reference: 21471337216.407.80104002.06EPA 3486957