BLUERIDGE / AIR-SOURCE HEAT PUMP

BHP17L24P-**A

BHP17 SERIES · BHP17 Series · BHP17L SERIES · BHP17L Series

143 published source records · source checked Sep 21, 2026

SEER2 range15.4–17BTU/Wh
HSPF2 range7.8–8.2BTU/Wh
Cooling capacity22,600–24,000BTU/h

Each efficiency range summarizes published EPA records for BHP17L24P-**A. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 143 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.4–17143 / 143
EER2 · BTU/Wh12.5–14143 / 143
HSPF2 · BTU/Wh7.8–8.2143 / 143
Cooling capacity · BTU/h22,600–24,000143 / 143
Heating capacity at 47°F / 8.3°C · BTU/h21,000–22,600143 / 143
Heating capacity at 17°F / −8.3°C · BTU/h13,400–14,700143 / 143
Heating capacity at 5°F / −15°C · BTU/h10,200–11,500143 / 143
COP at 5°F / −15°C2–2.14143 / 143
Equipment / loop typeHP - Split System143 / 143
Refrigerant / source-reported GWPR-410A (GWP:2088)143 / 143
Compressor stagingSingle stage143 / 143
Connected capabilityNo143 / 143

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
BH1P30B*+TDR+TXV+ furnace: BG802UH090BE16AHRI reference: 21173514817.008.00103002.06EPA 2471276
BH1P30B*+TDR+TXV+ furnace: BG801UH090BE16AHRI reference: 21173522617.008.00104002.10EPA 2837318
BC730HBT-0*+TDR+ furnace: BG802UH090BE16AHRI reference: 21471333417.008.00103002.06EPA 3487013
BC730HBT-0*+TDR+ furnace: BG801UH090BE16AHRI reference: 21471333617.008.00104002.10EPA 3487016
BH1P30B*+TDR+TXV+ furnace: BG802UH090BE12AHRI reference: 21173513616.807.80103002.06EPA 2471506
BH1P30B*+TDR+TXV+ furnace: BG801UH070BE12AHRI reference: 21173521016.808.00104002.06EPA 2837330
BC730HBT-0*+TDR+ furnace: BG801UH070BE12AHRI reference: 21471333516.808.00104002.06EPA 3487014
BC730HBT-0*+TDR+ furnace: BG802UH090BE12AHRI reference: 21471333316.807.80103002.06EPA 3491749
BC1P30A+TDR+TXV+ furnace: BG801UH090BE16AHRI reference: 21032551316.608.00104002.06EPA 2472186
BC4X30B+TDR+ furnace: BG801UH090BE16AHRI reference: 21044124116.608.00104002.06EPA 2472358
BC1P30B+TDR+TXV+ furnace: BG801UH090BE16AHRI reference: 21044120516.608.00104002.06EPA 2472458
BH1P30B*+TDR+TXV+ furnace: BG921UH070BE12AHRI reference: 21173527216.608.00106002.06EPA 2837310
BC730CBT-0*+TDR+ furnace: BG801UH090BE16AHRI reference: 21471337316.608.00104002.06EPA 3486961
BC730HBT-0*+TDR+ furnace: BG921UH070BE12AHRI reference: 21471333816.608.00106002.06EPA 3487127
BC1P30B+TDR+TXV+ furnace: BG802UH090BE16AHRI reference: 21044120216.408.00104002.06EPA 2471198
BC1P24B+TDR+TXV+ furnace: BG802UH090BE16AHRI reference: 21044119116.407.80104002.04EPA 2471214
BH1P30A*+TDR+TXV+ furnace: BG802UH070AV12AHRI reference: 21173510516.408.10106002.12EPA 2471359
BC1P24A+TDR+TXV+ furnace: BG802UH090BE16AHRI reference: 21032548616.407.80104002.04EPA 2471383
BH1P30A*+TDR+TXV+ furnace: BG801UH045AE12AHRI reference: 21173506816.408.00102002.08EPA 2471515
BH1P30A*+TDR+TXV+ furnace: BG801UH070AE12AHRI reference: 21173508216.408.00104002.14EPA 2471529

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →