BLUERIDGE / AIR-SOURCE HEAT PUMP

BHP17L18P-**A

BHP17 SERIES · BHP17 Series · BHP17L SERIES · BHP17L Series · source records, page 7

142 published source records · source checked Sep 21, 2026

SEER2 range15.2–16.8BTU/Wh
HSPF2 range7.8–8.4BTU/Wh
Cooling capacity18,000BTU/h

Each efficiency range summarizes published EPA records for BHP17L18P-**A. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 142 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16.8142 / 142
EER2 · BTU/Wh12.2–14142 / 142
HSPF2 · BTU/Wh7.8–8.4142 / 142
Cooling capacity · BTU/h18,000142 / 142
Heating capacity at 47°F / 8.3°C · BTU/h17,000–18,000142 / 142
Heating capacity at 17°F / −8.3°C · BTU/h10,400–11,800142 / 142
Heating capacity at 5°F / −15°C · BTU/h7,600–9,300142 / 142
COP at 5°F / −15°C1.9–2.14142 / 142
Equipment / loop typeHP - Split System142 / 142
Refrigerant / source-reported GWPR-410A (GWP:2088)142 / 142
Compressor stagingSingle stage142 / 142
Connected capabilityNo142 / 142

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
BC724CBT-0*+TDR+ furnace: BG961UH045BE12AHRI reference: 21471330416.008.0082002.04EPA 3487211
BC724CBT-0*+TDR+ furnace: BG961UH070BE12AHRI reference: 21471330516.008.0082002.08EPA 3487212
BAH7V18PT-0*AHRI reference: 21486611216.008.1082002.08EPA 3553888
BAH7E24PT-0*AHRI reference: 21486616616.008.1085002.14EPA 3553929
BE5V24MA4XAHRI reference: 21117438215.608.1084002.12EPA 2459925
BH1P30B*+TDR+TXV+ furnace: BG801UH090BE16AHRI reference: 21173474515.607.8080001.92EPA 2464075
BH1P30B*+TDR+TXV+ furnace: BG802UH090BE16AHRI reference: 21173468115.607.8080001.92EPA 2466167
BC730HBT-0*+TDR+ furnace: BG802UH090BE16AHRI reference: 21471328015.607.8080001.92EPA 3486900
BC730HBT-0*+TDR+ furnace: BG801UH090BE16AHRI reference: 21471328215.607.8080001.92EPA 3486968
BAH7V24PT-0*AHRI reference: 21486614215.608.1084002.12EPA 3553923
BE5C24MA4XAHRI reference: 21117437315.408.1085002.10EPA 2459914
BAH7P24PT-0*AHRI reference: 21486614015.408.1085002.10EPA 3553922
BC4X30B+TDR+ furnace: BG801UH090BE16AHRI reference: 21044118315.207.8081001.94EPA 2456471
BC4X30B+TDR+ furnace: BG802UH090BE16AHRI reference: 21044118015.207.8081001.90EPA 2456482
BE5C18MA4XAHRI reference: 21044115115.208.0085002.02EPA 2457303
BC1P30A+TDR+TXV+ furnace: BG802UH090BE16AHRI reference: 21032562315.207.8081001.90EPA 2457631
BC1P30B+TDR+TXV+ furnace: BG802UH090BE16AHRI reference: 21044114115.207.8081001.90EPA 2458551
BC1P30B+TDR+TXV+ furnace: BG801UH090BE16AHRI reference: 21044114415.207.8081001.94EPA 2458560
BC1P30A+TDR+TXV+ furnace: BG801UH090BE16AHRI reference: 21032562115.207.8081001.94EPA 2460631
BC730CBT-0*+TDR+ furnace: BG802UH090BE16AHRI reference: 21471331415.207.8081001.90EPA 3486894

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →