BLUERIDGE / AIR-SOURCE HEAT PUMP

BHP17L18P-**A

BHP17 SERIES · BHP17 Series · BHP17L SERIES · BHP17L Series · source records, page 6

142 published source records · source checked Sep 21, 2026

SEER2 range15.2–16.8BTU/Wh
HSPF2 range7.8–8.4BTU/Wh
Cooling capacity18,000BTU/h

Each efficiency range summarizes published EPA records for BHP17L18P-**A. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 142 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16.8142 / 142
EER2 · BTU/Wh12.2–14142 / 142
HSPF2 · BTU/Wh7.8–8.4142 / 142
Cooling capacity · BTU/h18,000142 / 142
Heating capacity at 47°F / 8.3°C · BTU/h17,000–18,000142 / 142
Heating capacity at 17°F / −8.3°C · BTU/h10,400–11,800142 / 142
Heating capacity at 5°F / −15°C · BTU/h7,600–9,300142 / 142
COP at 5°F / −15°C1.9–2.14142 / 142
Equipment / loop typeHP - Split System142 / 142
Refrigerant / source-reported GWPR-410A (GWP:2088)142 / 142
Compressor stagingSingle stage142 / 142
Connected capabilityNo142 / 142

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
BC1P24A+TDR+TXV+ furnace: BG961UH045BE12AHRI reference: 21032557716.008.0082002.04EPA 2458318
BC1P24B+TDR+TXV+ furnace: BG961UH070BE12AHRI reference: 21044113816.008.0082002.08EPA 2458520
BC4X24B+TDR+ furnace: BG961UH045BE12AHRI reference: 21044117116.008.0082002.04EPA 2458590
BC1P24B+TDR+TXV+ furnace: BG961UH045BE12AHRI reference: 21044113716.008.0082002.04EPA 2458853
BC4X24B+TDR+ furnace: BG802UH090BV16AHRI reference: 21044117316.008.1085002.06EPA 2458862
BC1P24A+TDR+TXV+ furnace: BG921UH045BE12AHRI reference: 21032557916.008.0082002.06EPA 2458999
BC4X24A+TDR+ furnace: BG802UH070AV12AHRI reference: 21044116316.008.1085002.06EPA 2459176
BC1P24A+TDR+TXV+ furnace: BG802UH090BV16AHRI reference: 21032559416.008.1085002.06EPA 2461144
BH1P24B*+TDR+TXV+ furnace: BG961UH070BE12AHRI reference: 21173461116.008.1082002.06EPA 2463641
BH1P24A*+TDR+TXV+ furnace: BG802UH070AV12AHRI reference: 21173438416.008.1087002.04EPA 2463651
BH1P24B*+TDR+TXV+ furnace: BG802UH090BV16AHRI reference: 21173462816.008.1087002.08EPA 2464462
BH1P24B*+TDR+TXV+ furnace: BG961UH045BE12AHRI reference: 21173459816.008.1082002.06EPA 2465725
BC724HBT-0*+TDR+ furnace: BG961UH045BE12AHRI reference: 21471327516.008.1082002.06EPA 3486611
BC724HBT-0*+TDR+ furnace: BG961UH070BE12AHRI reference: 21471327616.008.1082002.06EPA 3486673
BC724HBT-0*+TDR+ furnace: BG802UH090BV16AHRI reference: 21471327716.008.1087002.08EPA 3486893
BC724HAT-0*+TDR+ furnace: BG802UH070AV12AHRI reference: 21471326816.008.1087002.04EPA 3487057
BC730/36DCT-0*+TDR+ furnace: BG96G1DF090CE16AHRI reference: 21471329316.008.4093002.06EPA 3487077
BC724CAT-0*+TDR+ furnace: BG802UH070AV12AHRI reference: 21471329716.008.1085002.06EPA 3487081
BC724CBT-0*+TDR+ furnace: BG802UH090BV16AHRI reference: 21471330616.008.1085002.06EPA 3487191
BC724CBT-0*+TDR+ furnace: BG921UH045BE12AHRI reference: 21471330216.008.0082002.06EPA 3487209

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →