A7SCP18V36P-**A
A7SCP18V Series · source records, page 9
216 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for A7SCP18V36P-**A. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 216 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–19 | 216 / 216 |
| EER2 · BTU/Wh | 10–12 | 216 / 216 |
| HSPF2 · BTU/Wh | 8.1–9.6 | 216 / 216 |
| Cooling capacity · BTU/h | 32,200–36,000 | 216 / 216 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 34,000–38,500 | 216 / 216 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 27,000–29,600 | 216 / 216 |
| Heating capacity at 5°F / −15°C · BTU/h | 28,000–30,800 | 216 / 216 |
| COP at 5°F / −15°C | 1.8–1.95 | 216 / 216 |
| Equipment / loop type | HP - Split System | 216 / 216 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 216 / 216 |
| Compressor staging | Continuously variable | 216 / 216 |
| Connected capability | No | 216 / 216 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
7E[C,U]36CX-**+TDR+ furnace: A97UH2E090C16S*Cold climate designationAHRI reference: 218082956 | 17.20 | 8.50 | 28200 | 1.90 | EPA 4569964 → |
7EH36AX-**+TDR+ furnace: A80UH1E045A12*Cold climate designationAHRI reference: 217188998 | 17.15 | 8.50 | 28800 | 1.80 | EPA 4007104 → |
7E[C,U]30BX-**+TDR+ furnace: A93UH1E045B12A*Cold climate designationAHRI reference: 217450331 | 17.15 | 8.50 | 28800 | 1.80 | EPA 4046332 → |
7E[C,U]30BX-**+TDR+ furnace: A97US2V060B12X*Cold climate designationAHRI reference: 216769677 | 17.10 | 8.50 | 28600 | 1.80 | EPA 3984013 → |
7E[C,U]30BX-**+TDR+ furnace: A96UH1E045B12S*Cold climate designationAHRI reference: 217188950 | 17.10 | 8.50 | 28600 | 1.80 | EPA 4007375 → |
7EH36BX-**+TDR+ furnace: A93UH1E030B12A*Cold climate designationAHRI reference: 217450363 | 17.10 | 8.50 | 28600 | 1.85 | EPA 4046554 → |
7E[C,U]36BX-**+TDR+ furnace: A80UH1E090B16*Cold climate designationAHRI reference: 217188972 | 17.05 | 8.50 | 28200 | 1.90 | EPA 4007077 → |
7EH36BX-**+TDR+ furnace: A80DF1E090B16*Cold climate designationAHRI reference: 217189007 | 17.05 | 8.50 | 28400 | 1.85 | EPA 4007200 → |
7ED30/36BX-**+TDR+ furnace: A97DS2V045B12S*Cold climate designationAHRI reference: 217450376 | 17.05 | 8.50 | 28600 | 1.85 | EPA 4046444 → |
7ED30/36BX-***+TDR+ furnace: A97DS2V045B12S*Cold climate designationAHRI reference: 218114566 | 17.05 | 8.50 | 28600 | 1.85 | EPA 4573209 → |
7E[C,U]30BX-**+TDR+ furnace: A97US2V045B12S*Cold climate designationAHRI reference: 216769679 | 17.00 | 8.50 | 28600 | 1.80 | EPA 3983700 → |
7E[C,U]30AX-**+TDR+ furnace: A80US2V070A12*Cold climate designationAHRI reference: 217188940 | 17.00 | 8.50 | 28600 | 1.80 | EPA 4007398 → |
7E[C,U]30AX-**+TDR+ furnace: A80US2V070A12L*Cold climate designationAHRI reference: 217450325 | 17.00 | 8.50 | 28600 | 1.80 | EPA 4046325 → |
7EH30BX-**+TDR+ furnace: A80UH1E090B16*Cold climate designationAHRI reference: 217188989 | 16.95 | 8.50 | 28200 | 1.85 | EPA 4007035 → |
7EH36AX-**+TDR+ furnace: A80UH1E040A12X*Cold climate designationAHRI reference: 217188993 | 16.95 | 8.50 | 28800 | 1.80 | EPA 4007074 → |
7EH36AX-**+TDR+ furnace: A80UH1E060A12X*Cold climate designationAHRI reference: 217188994 | 16.95 | 8.50 | 28800 | 1.80 | EPA 4007075 → |
7E[C,U]36BX-**+TDR+ furnace: A80UH2E090B16*Cold climate designationAHRI reference: 217188971 | 16.95 | 8.50 | 28200 | 1.90 | EPA 4007076 → |
7EH36AX-**+TDR+ furnace: A80UH1E070A12*Cold climate designationAHRI reference: 217188997 | 16.95 | 8.50 | 28800 | 1.80 | EPA 4007103 → |
7ED30/36BX-**+TDR+ furnace: A96DF1E070B16S*Cold climate designationAHRI reference: 217189014 | 16.95 | 8.50 | 28800 | 1.85 | EPA 4008143 → |
7ED30/36BX-**+TDR+ furnace: A80DS2V090B16*Cold climate designationAHRI reference: 217450379 | 16.95 | 8.50 | 28600 | 1.85 | EPA 4046407 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →