Each efficiency range summarizes published EPA records for A7SCP18V36P-**A. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 216 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–19 | 216 / 216 |
| EER2 · BTU/Wh | 10–12 | 216 / 216 |
| HSPF2 · BTU/Wh | 8.1–9.6 | 216 / 216 |
| Cooling capacity · BTU/h | 32,200–36,000 | 216 / 216 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 34,000–38,500 | 216 / 216 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 27,000–29,600 | 216 / 216 |
| Heating capacity at 5°F / −15°C · BTU/h | 28,000–30,800 | 216 / 216 |
| COP at 5°F / −15°C | 1.8–1.95 | 216 / 216 |
| Equipment / loop type | HP - Split System | 216 / 216 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 216 / 216 |
| Compressor staging | Continuously variable | 216 / 216 |
| Connected capability | No | 216 / 216 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
7ED30/36BX-**+TDR+ furnace: A93DF1E045B12A*Cold climate designationAHRI reference: 217450377 | 16.95 | 8.50 | 28200 | 1.85 | EPA 4046445 → |
7ED30/36BX-***+TDR+ furnace: A80DS2V090B16*Cold climate designationAHRI reference: 218114572 | 16.95 | 8.50 | 28600 | 1.85 | EPA 4573203 → |
7ED30/36BX-***+TDR+ furnace: A93DF1E045B12A*Cold climate designationAHRI reference: 218114568 | 16.95 | 8.50 | 28200 | 1.85 | EPA 4573207 → |
7ED30/36BX-***+TDR+ furnace: A96DF1E070B16S*Cold climate designationAHRI reference: 218114562 | 16.95 | 8.50 | 28800 | 1.85 | EPA 4573213 → |
7E[C,U]30BX-**+TDR+ furnace: A80DF1E090B16*Cold climate designationAHRI reference: 217188956 | 16.90 | 8.50 | 28400 | 1.85 | EPA 4007156 → |
7EH36BX-**+TDR+ furnace: A80UH1E090B16*Cold climate designationAHRI reference: 217189006 | 16.90 | 8.50 | 28200 | 1.85 | EPA 4007199 → |
7ED30/36BX-**+TDR+ furnace: A97DSMV070B12S*Cold climate designationAHRI reference: 217189012 | 16.85 | 8.50 | 28600 | 1.85 | EPA 4007048 → |
7ED30/36BX-***+TDR+ furnace: A97DSMV070B12S*Cold climate designationAHRI reference: 218114558 | 16.85 | 8.50 | 28600 | 1.85 | EPA 4573217 → |
7EH30BX-**+TDR+ furnace: A80UH2E090B16*Cold climate designationAHRI reference: 217188988 | 16.80 | 8.50 | 28200 | 1.85 | EPA 4007034 → |
7EH36BX-**+TDR+ furnace: A80UH2E090B16*Cold climate designationAHRI reference: 217189005 | 16.75 | 8.50 | 28200 | 1.85 | EPA 4007198 → |
7EH36AX-**+TDR+ furnace: A80UH2E070A12*Cold climate designationAHRI reference: 217188995 | 16.70 | 8.50 | 28800 | 1.80 | EPA 4006977 → |
7EH36AX-**+TDR+ furnace: A80US2V060A12X*Cold climate designationAHRI reference: 217188992 | 16.65 | 8.50 | 28800 | 1.80 | EPA 4007073 → |
7E[C,U]30BX-**+TDR+ furnace: A80UH1E090B16*Cold climate designationAHRI reference: 217188955 | 16.65 | 8.50 | 28400 | 1.85 | EPA 4007155 → |
7E[C,U]36CX-**+TDR+ furnace: A80UH1E110C20*Cold climate designationAHRI reference: 218082968 | 16.65 | 8.50 | 28200 | 1.90 | EPA 4569952 → |
7ED30/36BX-**+TDR+ furnace: A97DF2E045B12S*Cold climate designationAHRI reference: 217450375 | 16.60 | 8.50 | 28200 | 1.85 | EPA 4046443 → |
7ED30/36BX-***+TDR+ furnace: A97DF2E045B12S*Cold climate designationAHRI reference: 218114564 | 16.60 | 8.50 | 28200 | 1.85 | EPA 4573211 → |
7E[C,U]30BX-**+TDR+ furnace: A80UH2E090B16*Cold climate designationAHRI reference: 217188954 | 16.55 | 8.50 | 28400 | 1.85 | EPA 4007379 → |
7ED30/36BX-**+TDR+ furnace: A97DS2V070B16S*Cold climate designationAHRI reference: 216769711 | 16.50 | 8.50 | 28600 | 1.85 | EPA 3983569 → |
7ED30/36BX-***+TDR+ furnace: A97DS2V070B16S*Cold climate designationAHRI reference: 218114554 | 16.50 | 8.50 | 28600 | 1.85 | EPA 4573221 → |
7E[C,U]36BX-**+TDR+ furnace: A80UH1E080B16X*Cold climate designationAHRI reference: 217188970 | 16.40 | 8.50 | 28600 | 1.85 | EPA 4007297 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →