Heating performance & equipment details
Ranges include the 134 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–18.5 | 134 / 134 |
| EER2 · BTU/Wh | 11–12.3 | 134 / 134 |
| HSPF2 · BTU/Wh | 8.5–10 | 134 / 134 |
| Cooling capacity · BTU/h | 23,200–24,200 | 134 / 134 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 23,800–24,800 | 134 / 134 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 18,000–20,200 | 134 / 134 |
| Heating capacity at 5°F / −15°C · BTU/h | 20,000–23,400 | 134 / 134 |
| COP at 5°F / −15°C | 1.75–1.85 | 134 / 134 |
| Equipment / loop type | HP - Split System | 134 / 134 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 134 / 134 |
| Compressor staging | Continuously variable | 134 / 134 |
| Connected capability | No | 134 / 134 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
7E[C,U]30AX-**+TDR+ furnace: A80UH1E045A12*Cold climate designationAHRI reference: 217188887 | 16.85 | 9.00 | 20800 | 1.80 | EPA 4007127 → |
7EH30AX-**+TDR+ furnace: A80UH1E070A12*Cold climate designationAHRI reference: 217188930 | 16.85 | 9.40 | 20800 | 1.85 | EPA 4007371 → |
7E[C,U]30BX-**+TDR+ furnace: A80UH2E090B12*Cold climate designationAHRI reference: 217450285 | 16.85 | 9.00 | 20600 | 1.80 | EPA 4046056 → |
7E[C,U]30BX-**+TDR+ furnace: A93UH1E030B12A*Cold climate designationAHRI reference: 217450289 | 16.85 | 9.00 | 21000 | 1.80 | EPA 4046613 → |
7E[C,U]30BX-**+TDR+ furnace: A93UH1E045B12A*Cold climate designationAHRI reference: 217450290 | 16.85 | 9.00 | 21000 | 1.80 | EPA 4046614 → |
7EH24BX-**+TDR+ furnace: A80UH1E070B12*Cold climate designationAHRI reference: 217188920 | 16.80 | 9.00 | 20800 | 1.80 | EPA 4007193 → |
7ED24AX-**+TDR+ furnace: A80DS2V070A12*Cold climate designationAHRI reference: 217450320 | 16.80 | 9.00 | 21000 | 1.80 | EPA 4046501 → |
7EH24AX-**+TDR+ furnace: A80US2V060A12X*Cold climate designationAHRI reference: 217188913 | 16.75 | 9.00 | 21000 | 1.80 | EPA 4007146 → |
7EH24AX-**+TDR+ furnace: A80UH1E045A12*Cold climate designationAHRI reference: 217188919 | 16.75 | 9.00 | 21000 | 1.80 | EPA 4007192 → |
7E[C,U]30AX-**+TDR+ furnace: A80US2V070A12*Cold climate designationAHRI reference: 217188880 | 16.70 | 9.00 | 20800 | 1.80 | EPA 4007030 → |
7E[C,U]30AX-**+TDR+ furnace: A80UH2E070A12*Cold climate designationAHRI reference: 217188884 | 16.70 | 9.00 | 20600 | 1.80 | EPA 4007124 → |
7E[C,U]36AX-**+TDR+ furnace: A80UH1E070A12*Cold climate designationAHRI reference: 217188898 | 16.70 | 9.00 | 20600 | 1.85 | EPA 4007258 → |
7E[C,U]36BX-**+TDR+ furnace: A80UH1E070B12*Cold climate designationAHRI reference: 217188900 | 16.70 | 9.00 | 20600 | 1.85 | EPA 4007355 → |
7E[C,U]30AX-**+TDR+ furnace: A80US2V070A12L*Cold climate designationAHRI reference: 217450283 | 16.70 | 9.00 | 20800 | 1.80 | EPA 4046249 → |
7EH24BX-**+TDR+ furnace: A97UH2E045B12S*Cold climate designationAHRI reference: 217450305 | 16.70 | 9.00 | 21000 | 1.80 | EPA 4046412 → |
7EH30BX-**+TDR+ furnace: A80UH1E070B12*Cold climate designationAHRI reference: 217188932 | 16.65 | 9.00 | 20800 | 1.80 | EPA 4007149 → |
7ED24AX-**+TDR+ furnace: A80DF1E045A12*Cold climate designationAHRI reference: 217188936 | 16.65 | 9.00 | 21000 | 1.80 | EPA 4007153 → |
7EH24AX-**+TDR+ furnace: A80UH2E070A12*Cold climate designationAHRI reference: 217188916 | 16.65 | 9.00 | 20800 | 1.80 | EPA 4007189 → |
7EH24BX-**+TDR+ furnace: A97UH2E070B12S*Cold climate designationAHRI reference: 217450306 | 16.60 | 9.00 | 21000 | 1.80 | EPA 4046413 → |
7E[C,U]36BX-**+TDR+ furnace: A97UH2E045B12S*Cold climate designationAHRI reference: 217450295 | 16.60 | 9.00 | 20800 | 1.80 | EPA 4046425 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →