A7SCP18V24P-**A
A7SCP18V Series · source records, page 4
134 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for A7SCP18V24P-**A. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 134 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–18.5 | 134 / 134 |
| EER2 · BTU/Wh | 11–12.3 | 134 / 134 |
| HSPF2 · BTU/Wh | 8.5–10 | 134 / 134 |
| Cooling capacity · BTU/h | 23,200–24,200 | 134 / 134 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 23,800–24,800 | 134 / 134 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 18,000–20,200 | 134 / 134 |
| Heating capacity at 5°F / −15°C · BTU/h | 20,000–23,400 | 134 / 134 |
| COP at 5°F / −15°C | 1.75–1.85 | 134 / 134 |
| Equipment / loop type | HP - Split System | 134 / 134 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 134 / 134 |
| Compressor staging | Continuously variable | 134 / 134 |
| Connected capability | No | 134 / 134 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
7E[C,U]36AX-**+TDR+ furnace: A80UH2E070A12*Cold climate designationAHRI reference: 217188896 | 17.10 | 9.00 | 20400 | 1.85 | EPA 4007256 → |
7EH24BX-**+TDR+ furnace: A96UH1E030B12S*Cold climate designationAHRI reference: 217450307 | 17.10 | 9.00 | 21000 | 1.80 | EPA 4046414 → |
7EH30BX-**+TDR+ furnace: A93UH1E030B12A*Cold climate designationAHRI reference: 217450317 | 17.10 | 9.00 | 21000 | 1.80 | EPA 4046498 → |
7EH30BX-**+TDR+ furnace: A93UH1E045B12A*Cold climate designationAHRI reference: 217450318 | 17.10 | 9.00 | 21000 | 1.80 | EPA 4046499 → |
7E[C,U]30AX-**+TDR+ furnace: A80UH1E040A12X*Cold climate designationAHRI reference: 217188882 | 17.05 | 9.00 | 20800 | 1.80 | EPA 4007032 → |
7E[C,U]30AX-**+TDR+ furnace: A80UH1E060A12X*Cold climate designationAHRI reference: 217188883 | 17.05 | 9.00 | 20800 | 1.80 | EPA 4007123 → |
7E[C,U]36AX-**+TDR+ furnace: A80US2V070A12*Cold climate designationAHRI reference: 217188892 | 17.05 | 9.00 | 20800 | 1.85 | EPA 4007252 → |
7E[C,U]36AX-**+TDR+ furnace: A80US2V070A12L*Cold climate designationAHRI reference: 217450292 | 17.05 | 9.00 | 20800 | 1.85 | EPA 4046423 → |
7AH2AV24PXC-**Cold climate designationAHRI reference: 216618962 | 17.00 | 9.40 | 23200 | 1.80 | EPA 3893218 → |
7AH2AE24PX-**Cold climate designationAHRI reference: 216705377 | 17.00 | 9.50 | 22600 | 1.85 | EPA 3893239 → |
7E[C,U]30BX-**+TDR+ furnace: A97US2V060B12X*Cold climate designationAHRI reference: 216769629 | 17.00 | 9.00 | 20800 | 1.80 | EPA 3983591 → |
7E[C,U]30BX-**+TDR+ furnace: A96UH1E030B12S*Cold climate designationAHRI reference: 217450288 | 17.00 | 9.00 | 20800 | 1.80 | EPA 4046058 → |
7E[C,U]30BX-**+TDR+ furnace: A93UH1E070B12A*Cold climate designationAHRI reference: 217450291 | 17.00 | 9.00 | 20800 | 1.80 | EPA 4046059 → |
7ED24BX-**+TDR+ furnace: A93DF1E070B12A*Cold climate designationAHRI reference: 217450324 | 17.00 | 9.40 | 21000 | 1.80 | EPA 4046326 → |
7E[C,U]30BX-**+TDR+ furnace: A97US2V045B12S*Cold climate designationAHRI reference: 216769631 | 16.95 | 9.00 | 20800 | 1.80 | EPA 3983593 → |
7EH24AX-**+TDR+ furnace: A80UH1E040A12X*Cold climate designationAHRI reference: 217188914 | 16.95 | 9.00 | 21000 | 1.80 | EPA 4007147 → |
7EH24AX-**+TDR+ furnace: A80UH1E060A12X*Cold climate designationAHRI reference: 217188915 | 16.95 | 9.00 | 21000 | 1.80 | EPA 4007187 → |
7ED24BX-**+TDR+ furnace: A97DS2V045B12S*Cold climate designationAHRI reference: 217450322 | 16.95 | 9.40 | 20800 | 1.80 | EPA 4046503 → |
7ED24BX-**+TDR+ furnace: A93DF1E045B12A*Cold climate designationAHRI reference: 217450323 | 16.90 | 9.40 | 21000 | 1.80 | EPA 4046504 → |
7E[C,U]30AX-**+TDR+ furnace: A80US2V060A12X*Cold climate designationAHRI reference: 217188881 | 16.85 | 9.00 | 20800 | 1.80 | EPA 4007031 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →