Q5H9V48*K*AAA*
QuietComfort 19 SEER2 VS HP · source records, page 13
507 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for Q5H9V48*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 507 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–19 | 507 / 507 |
| EER2 · BTU/Wh | 10–13.5 | 507 / 507 |
| HSPF2 · BTU/Wh | 8.5–10 | 507 / 507 |
| Cooling capacity · BTU/h | 43,500–49,500 | 507 / 507 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 46,500–55,000 | 507 / 507 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 38,500–47,000 | 507 / 507 |
| Heating capacity at 5°F / −15°C · BTU/h | 36,000–41,500 | 507 / 507 |
| COP at 5°F / −15°C | 1.95–2.32 | 507 / 507 |
| Equipment / loop type | HP - Split System | 507 / 507 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 507 / 507 |
| Compressor staging | Continuously variable | 507 / 507 |
| Connected capability | No | 507 / 507 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
EVM5X60M21A*+ furnace: *97CTN0802120A*Cold climate designationAHRI reference: 217955339 | 16.00 | 9.00 | 40500 | 2.10 | EPA 4565820 → |
EVM5X60M21A*+ furnace: *97CTN1002122A*Cold climate designationAHRI reference: 217955341 | 16.00 | 9.00 | 41000 | 2.12 | EPA 4565822 → |
EVM5X60M21A*+ furnace: *96VTN0802120B*Cold climate designationAHRI reference: 217955343 | 16.00 | 9.50 | 40500 | 2.24 | EPA 4565824 → |
EVM5X60M21A*+ furnace: *97VTN0802120A*Cold climate designationAHRI reference: 217955349 | 16.00 | 9.50 | 40500 | 2.24 | EPA 4565830 → |
EVD5X61M24A*+ furnace: *96CTN1002122B*Cold climate designationAHRI reference: 217955643 | 16.00 | 9.00 | 40500 | 2.15 | EPA 4565845 → |
EVD5X61M24A*+ furnace: *96CTN1202422B*Cold climate designationAHRI reference: 217955645 | 16.00 | 9.00 | 40500 | 2.15 | EPA 4565847 → |
EVD5X61M24A*+ furnace: *97CTN1002122A*Cold climate designationAHRI reference: 217955649 | 16.00 | 9.00 | 40500 | 2.15 | EPA 4565852 → |
EVD5X61M24A*+ furnace: *97CTN1202422A*Cold climate designationAHRI reference: 217955651 | 16.00 | 9.00 | 40500 | 2.15 | EPA 4565855 → |
EA*5X61M24A*+ furnace: *97CMN0802120B*Cold climate designationAHRI reference: 217955969 | 16.00 | 9.00 | 37600 | 2.08 | EPA 4565857 → |
EA*5X61M24A*+ furnace: *97CMN1002122B*Cold climate designationAHRI reference: 217955971 | 16.00 | 9.00 | 37600 | 2.08 | EPA 4565860 → |
EA*5X61M24A*+ furnace: *96VSN1002120B*Cold climate designationAHRI reference: 217955977 | 16.00 | 9.00 | 37200 | 2.10 | EPA 4565867 → |
EA*5X61M24A*+ furnace: *96VSN1202422B*Cold climate designationAHRI reference: 217955979 | 16.00 | 9.00 | 37200 | 2.08 | EPA 4565869 → |
EVD5X61M24A*+ furnace: *96VTN0802120B*Cold climate designationAHRI reference: 217955653 | 16.00 | 9.00 | 41000 | 2.12 | EPA 4565885 → |
EVD5X61M24A*+ furnace: *96VTN1002120B*Cold climate designationAHRI reference: 217955655 | 16.00 | 9.00 | 40500 | 2.10 | EPA 4565887 → |
EVD5X61M24A*+ furnace: *97VTN0802120A*Cold climate designationAHRI reference: 217955661 | 16.00 | 9.00 | 41000 | 2.12 | EPA 4565893 → |
EVD5X61M24A*+ furnace: *97VTN1002120A*Cold climate designationAHRI reference: 217955663 | 16.00 | 9.00 | 40500 | 2.10 | EPA 4565895 → |
EA*5X48M21A*+ furnace: *80CSU0601716B*Cold climate designationAHRI reference: 217955683 | 16.00 | 9.00 | 36800 | 2.10 | EPA 4565912 → |
EA*5X48M21A*+ furnace: *80CSU1002120B*Cold climate designationAHRI reference: 217955687 | 16.00 | 9.00 | 36800 | 2.10 | EPA 4565915 → |
EA*5X48M21A*+ furnace: *80VSL0701716B*Cold climate designationAHRI reference: 217955689 | 16.00 | 9.00 | 37000 | 2.10 | EPA 4565917 → |
EA*5X61M21A*+ furnace: *96VTN0802120B*Cold climate designationAHRI reference: 217955927 | 16.00 | 9.00 | 37000 | 2.10 | EPA 4565931 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →