Arcoaire / AIR-SOURCE HEAT PUMP

Q5H9V48*K*AAA*

QuietComfort 19 SEER2 VS HP · source records, page 12

507 published source records · source checked Sep 21, 2026

SEER2 range15.2–19BTU/Wh
HSPF2 range8.5–10BTU/Wh
Cooling capacity43,500–49,500BTU/h

Each efficiency range summarizes published EPA records for Q5H9V48*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 507 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–19507 / 507
EER2 · BTU/Wh10–13.5507 / 507
HSPF2 · BTU/Wh8.5–10507 / 507
Cooling capacity · BTU/h43,500–49,500507 / 507
Heating capacity at 47°F / 8.3°C · BTU/h46,500–55,000507 / 507
Heating capacity at 17°F / −8.3°C · BTU/h38,500–47,000507 / 507
Heating capacity at 5°F / −15°C · BTU/h36,000–41,500507 / 507
COP at 5°F / −15°C1.95–2.32507 / 507
Equipment / loop typeHP - Split System507 / 507
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)507 / 507
Compressor stagingContinuously variable507 / 507
Connected capabilityNo507 / 507

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
EVD5X60M21A*+ furnace: *96VTN0802120B*Cold climate designationAHRI reference: 21795552316.009.50405002.24EPA 4565717 →
EVD5X60M21A*+ furnace: *97VTN0802120A*Cold climate designationAHRI reference: 21795552916.009.50405002.24EPA 4565724 →
EVM5X49M21A*+ furnace: *97CMN0802120B*Cold climate designationAHRI reference: 21795525516.009.00410002.12EPA 4565728 →
EVM5X49M21A*+ furnace: *97CMN1002122B*Cold climate designationAHRI reference: 21795525716.009.00410002.12EPA 4565730 →
EVM5X49M21A*+ furnace: *96VSN0802120B*Cold climate designationAHRI reference: 21795525916.009.00405002.10EPA 4565732 →
EVM5X49M21A*+ furnace: *96VSN1002120B*Cold climate designationAHRI reference: 21795526116.009.00405002.10EPA 4565734 →
EVM5X49M21A*+ furnace: *95MSU1002120A*Cold climate designationAHRI reference: 21795526516.009.00405002.10EPA 4565738 →
EVM5X49M21A*+ furnace: *96CTN1002122B*Cold climate designationAHRI reference: 21795527116.009.00410002.12EPA 4565744 →
EVM5X49M21A*+ furnace: *97CTN1002122A*Cold climate designationAHRI reference: 21795527516.009.00410002.12EPA 4565748 →
EVM5X49M21A*+ furnace: *96VTN0802120B*Cold climate designationAHRI reference: 21795527716.009.00405002.10EPA 4565750 →
EVM5X49M21A*+ furnace: *97VTN0802120A*Cold climate designationAHRI reference: 21795528316.009.00405002.10EPA 4565766 →
EVM5X60M21A*+ furnace: *80CSU1002120B*Cold climate designationAHRI reference: 21795529316.009.00400002.10EPA 4565776 →
EVM5X60M21A*+ furnace: *80VTL1102122B*Cold climate designationAHRI reference: 21795531316.009.50400002.24EPA 4565796 →
EVM5X60M21A*+ furnace: *97CMN0802120B*Cold climate designationAHRI reference: 21795532116.009.00410002.12EPA 4565802 →
EVM5X60M21A*+ furnace: *97CMN1002122B*Cold climate designationAHRI reference: 21795532316.009.00410002.12EPA 4565804 →
EVM5X60M21A*+ furnace: *96VSN0802120B*Cold climate designationAHRI reference: 21795532516.009.50405002.24EPA 4565806 →
EVM5X60M21A*+ furnace: *96VSN1002120B*Cold climate designationAHRI reference: 21795532716.009.50405002.24EPA 4565808 →
EVM5X60M21A*+ furnace: *95MSU1002120A*Cold climate designationAHRI reference: 21795533116.009.00405002.10EPA 4565812 →
EVM5X60M21A*+ furnace: *96CTN0802120B*Cold climate designationAHRI reference: 21795533516.009.00405002.10EPA 4565816 →
EVM5X60M21A*+ furnace: *96CTN1002122B*Cold climate designationAHRI reference: 21795533716.009.00410002.12EPA 4565818 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →