Arcoaire / AIR-SOURCE HEAT PUMP

H5H3V60*K*AAA*

Deluxe 23 VS Heat Pump · source records, page 2

55 published source records · source checked Sep 21, 2026

SEER2 range17–20BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity55,000–58,000BTU/h

Each efficiency range summarizes published EPA records for H5H3V60*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 55 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh17–2055 / 55
EER2 · BTU/Wh10.5–12.555 / 55
HSPF2 · BTU/Wh7.8–8.555 / 55
Cooling capacity · BTU/h55,000–58,00055 / 55
Heating capacity at 47°F / 8.3°C · BTU/h60,000–63,50052 / 55
Heating capacity at 17°F / −8.3°C · BTU/h46,000–49,00055 / 55
Heating capacity at 5°F / −15°C · BTU/h41,000–47,50055 / 55
COP at 5°F / −15°C1.95–2.0855 / 55
Equipment / loop typeHP - Split System55 / 55
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)55 / 55
Compressor stagingContinuously variable55 / 55
Connected capabilityNo55 / 55

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
EVD5X60M24A*+WALLCON+ furnace: *80CTL1352422B*AHRI reference: 21593925818.507.80410002.05EPA 3726924
EA*5X61M24A*+WALLCON+ furnace: *80CTL0702120B*Cold climate designationAHRI reference: 21593168818.508.50470002.02EPA 3727073
EA*5X61M24A*+WALLCON+ furnace: *95CSU0802120B*Cold climate designationAHRI reference: 21593172818.508.50465002.02EPA 3727549
EVM5X60M24A*+WALLCON+ furnace: *80CTL1352422B*AHRI reference: 21593885818.507.80410002.05EPA 3727562
EA*5X61M24A*+WALLCON+ furnace: *97CMN0802120B*Cold climate designationAHRI reference: 21593174818.508.50465002.02EPA 3727593
EA*5X61M24A*+WALLCON+ furnace: *97CMN1002122B*Cold climate designationAHRI reference: 21593175818.508.50465002.02EPA 3727601
EA*5X61M24A*+WALLCON+ furnace: *97CMN1202422B*Cold climate designationAHRI reference: 21593176818.508.50465002.02EPA 3727610
EVM5X60M24A*+WALLCON+ furnace: *96CTN1202422B*AHRI reference: 21593893818.507.80410002.05EPA 3728262
EA*5X61M24A*+WALLCON+ furnace: *96CTN1002122B*Cold climate designationAHRI reference: 21593177818.508.50465002.02EPA 3728408
EA*5X61M24A*+WALLCON+ furnace: *96CTN1202422B*Cold climate designationAHRI reference: 21593178818.508.50465002.02EPA 3728417
EVM5X61M24A*+WALLCON+ furnace: *97CMN1202422B*AHRI reference: 21593905818.507.80415002.05EPA 3731751
EVD5X61M21A*+WALLCON+ furnace: *97CMN1002122B*AHRI reference: 21593944818.507.80415002.00EPA 3731889
EVD5X61M21A*+WALLCON+ furnace: *96CTN1002122B*AHRI reference: 21593945818.507.80415002.00EPA 3731899
EVD5X61M24A*+WALLCON+ furnace: *97CMN1202422B*AHRI reference: 21593957818.507.80415002.05EPA 3732405
EVD5X60M24A*+WALLCON+ furnace: *96CTN1202422B*AHRI reference: 21593933818.507.80410002.05EPA 3733966
EVD5X61M21A*+WALLCON+ furnace: *97CTN1002122A*AHRI reference: 21594224818.507.80415002.00EPA 3736000
EA*5X60M24A*+WALLCON+ furnace: *97CTN1002122A*Cold climate designationAHRI reference: 21744827718.508.50460002.06EPA 4045693
EA*5X60M24A*+WALLCON+ furnace: *80CTL0702120B*Cold climate designationAHRI reference: 21593153818.008.10465001.95EPA 3725158
EA*5X60M24A*+WALLCON+ furnace: *97CMN0802120B*Cold climate designationAHRI reference: 21593160818.008.10460001.95EPA 3726164
EA*5X60M24A*+WALLCON+ furnace: *95CSU0802120B*Cold climate designationAHRI reference: 21593157818.008.10460001.95EPA 3726353

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →