Arcoaire / AIR-SOURCE HEAT PUMP

H5H3V60*K*AAA*

Deluxe 23 VS Heat Pump

55 published source records · source checked Sep 21, 2026

SEER2 range17–20BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity55,000–58,000BTU/h

Each efficiency range summarizes published EPA records for H5H3V60*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 55 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh17–2055 / 55
EER2 · BTU/Wh10.5–12.555 / 55
HSPF2 · BTU/Wh7.8–8.555 / 55
Cooling capacity · BTU/h55,000–58,00055 / 55
Heating capacity at 47°F / 8.3°C · BTU/h60,000–63,50052 / 55
Heating capacity at 17°F / −8.3°C · BTU/h46,000–49,00055 / 55
Heating capacity at 5°F / −15°C · BTU/h41,000–47,50055 / 55
COP at 5°F / −15°C1.95–2.0855 / 55
Equipment / loop typeHP - Split System55 / 55
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)55 / 55
Compressor stagingContinuously variable55 / 55
Connected capabilityNo55 / 55

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
FCMA5B60L0D*+WALLCONCold climate designationAHRI reference: 21593149020.008.50445002.06EPA 3724851
EA*5X60M24A*+WALLCON+ furnace: *80CSU0802120A*Cold climate designationAHRI reference: 21593151819.008.50455002.06EPA 3725138
EA*5X61M24A*+WALLCON+ furnace: *80CSU0802120A*Cold climate designationAHRI reference: 21593166819.008.50460002.04EPA 3727053
EA*5X61M24A*+WALLCON+ furnace: *80CSU1002120A*Cold climate designationAHRI reference: 21593167819.008.50465002.02EPA 3727063
EA*5X61M24A*+WALLCON+ furnace: *80CTL0902120B*Cold climate designationAHRI reference: 21593169819.008.50465002.04EPA 3727083
EA*5X61M24A*+WALLCON+ furnace: *80CTL1102120B*Cold climate designationAHRI reference: 21593170819.008.50465002.02EPA 3727093
EA*5X61M24A*+WALLCON+ furnace: *80CTL1352422B*Cold climate designationAHRI reference: 21593171819.008.50460002.04EPA 3727540
EVD5X60M21A*+WALLCON+ furnace: *80CTL0902120B*AHRI reference: 21593912818.507.80415002.05EPA 3724572
EVD5X60M21A*+WALLCON+ furnace: *80CTL1102120B*AHRI reference: 21593913818.507.80415002.05EPA 3724582
EA*5X60M24A*+WALLCON+ furnace: *80CSU1002120A*Cold climate designationAHRI reference: 21593152818.508.50460002.04EPA 3725148
EA*5X60M24A*+WALLCON+ furnace: *80CTL0902120B*Cold climate designationAHRI reference: 21593154818.508.50455002.06EPA 3726273
EA*5X60M24A*+WALLCON+ furnace: *97CMN1002122B*Cold climate designationAHRI reference: 21593161818.508.50460002.06EPA 3726286
EA*5X60M24A*+WALLCON+ furnace: *97CMN1202422B*Cold climate designationAHRI reference: 21593162818.508.50460002.05EPA 3726297
EA*5X60M24A*+WALLCON+ furnace: *96CTN1002122B*Cold climate designationAHRI reference: 21593163818.508.50460002.06EPA 3726306
EA*5X60M24A*+WALLCON+ furnace: *96CTN1202422B*Cold climate designationAHRI reference: 21593164818.508.50460002.06EPA 3726317
EA*5X60M24A*+WALLCON+ furnace: *80CTL1102120B*Cold climate designationAHRI reference: 21593155818.508.50455002.06EPA 3726329
EA*5X60M24A*+WALLCON+ furnace: *80CTL1352422B*Cold climate designationAHRI reference: 21593156818.508.50455002.08EPA 3726337
EA*5X60M24A*+WALLCON+ furnace: *95CSU1002122B*Cold climate designationAHRI reference: 21593158818.508.50455002.08EPA 3726358
EVM5X60M21A*+WALLCON+ furnace: *80CTL1102120B*AHRI reference: 21593873818.507.80415002.05EPA 3726445
EVM5X60M21A*+WALLCON+ furnace: *80CTL0902120B*AHRI reference: 21593872818.507.80415002.05EPA 3726579

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.