American Standard / AIR-SOURCE HEAT PUMP

5A6H6048A1

Silver 16 · source records, page 5

127 published source records · source checked Sep 21, 2026

SEER2 range15.2–16BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity43,000–46,500BTU/h

Each efficiency range summarizes published EPA records for 5A6H6048A1. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 127 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16127 / 127
EER2 · BTU/Wh11.5–12127 / 127
HSPF2 · BTU/Wh7.8–8.5127 / 127
Cooling capacity · BTU/h43,000–46,500127 / 127
Heating capacity at 47°F / 8.3°C · BTU/h41,500–43,500127 / 127
Heating capacity at 17°F / −8.3°C · BTU/h28,200–29,200127 / 127
Heating capacity at 5°F / −15°C · BTU/h21,800–22,600127 / 127
COP at 5°F / −15°C2.1–2.3127 / 127
Equipment / loop typeHP - Split System127 / 127
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)127 / 127
Compressor stagingSingle stage127 / 127
Connected capabilityNo127 / 127

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
5TXCD010AS3+TSTAT+ furnace: S9X1C100U5PSBAHRI reference: 21839582715.208.10222002.16EPA 4599306
5TXCD008AS3+TSTAT+ furnace: S9X1D120U5PSBAHRI reference: 21839582515.208.10222002.13EPA 4599308
5TXCD008AS3+TSTAT+ furnace: S9X1C100U5PSBAHRI reference: 21839582315.208.00224002.10EPA 4599310
5TXCD008AS3+TSTAT+ furnace: S9V2C100U4VSBAHRI reference: 21839581915.208.10226002.10EPA 4599312
5TXCD008AS3+TSTAT+ furnace: S8X2C080M5PTCAHRI reference: 21839581715.208.00226002.10EPA 4599314
5TXCD008AS3+TSTAT+ furnace: S8X2C080M5PSCAHRI reference: 21839581515.208.00226002.10EPA 4599316
5TXCD008AS3+TSTAT+ furnace: S8X1C080M5PTCAHRI reference: 21839581315.208.00226002.10EPA 4599318
5TXCD008AS3+TSTAT+ furnace: S8X1C080M5PSCAHRI reference: 21839581115.208.00226002.10EPA 4599320
5TXCD008AS3+TSTAT+ furnace: S8V2C100M5PDBAHRI reference: 21839580915.208.00226002.10EPA 4599322
5TXCD008AS3+TSTAT+ furnace: S9X2C100U5PSBAHRI reference: 21839580515.208.00224002.10EPA 4599324
5TXCD008AS3+TSTAT+ furnace: S9X2D120U5PSBAHRI reference: 21839580315.208.10222002.13EPA 4599326
5TXCD008AS3+TSTAT+ furnace: S8V2C100M5PCBAHRI reference: 21839580115.208.00226002.10EPA 4599328
5TXCC009AS3+TSTAT+ furnace: S9X2C100U5PSBAHRI reference: 21839579715.208.10220002.17EPA 4599330
5TXCC009AS3+TSTAT+ furnace: L8V1C100U5VSBAHRI reference: 21839579515.208.00222002.20EPA 4599332
5TXCC009AS3+TSTAT+ furnace: S9V2C100U4VSBAHRI reference: 21839579115.208.10222002.17EPA 4599334
5TXCC009AS3+TSTAT+ furnace: S9V2C100U5VSBAHRI reference: 21839578915.208.10222002.16EPA 4599336
5TXCC009AS3+TSTAT+ furnace: S9X1C080U5PSBAHRI reference: 21839578715.207.80220002.18EPA 4599338
5TXCC009AS3+TSTAT+ furnace: S9X1C100U5PSBAHRI reference: 21839578515.208.10220002.17EPA 4599340
5TXCC009AS3+TSTAT+ furnace: S9X2C080U5PSBAHRI reference: 21839578315.207.80220002.18EPA 4599342
5PX*DD10AS3+TSTAT+ furnace: S9X2D120D5PSBAHRI reference: 21839576315.208.10220002.13EPA 4599344

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →