American Standard / AIR-SOURCE HEAT PUMP

5A6H6048A1

Silver 16 · source records, page 4

127 published source records · source checked Sep 21, 2026

SEER2 range15.2–16BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity43,000–46,500BTU/h

Each efficiency range summarizes published EPA records for 5A6H6048A1. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 127 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16127 / 127
EER2 · BTU/Wh11.5–12127 / 127
HSPF2 · BTU/Wh7.8–8.5127 / 127
Cooling capacity · BTU/h43,000–46,500127 / 127
Heating capacity at 47°F / 8.3°C · BTU/h41,500–43,500127 / 127
Heating capacity at 17°F / −8.3°C · BTU/h28,200–29,200127 / 127
Heating capacity at 5°F / −15°C · BTU/h21,800–22,600127 / 127
COP at 5°F / −15°C2.1–2.3127 / 127
Equipment / loop typeHP - Split System127 / 127
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)127 / 127
Compressor stagingSingle stage127 / 127
Connected capabilityNo127 / 127

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
5PX*DD10AS3+TSTAT+ furnace: S8X2D120M5PSCAHRI reference: 21810898515.208.00222002.14EPA 4574097
5PX*D010AS3+TSTAT+ furnace: S9V2C080U5VSBAHRI reference: 21810898115.208.10220002.18EPA 4574101
5PX*D010AS3+TSTAT+ furnace: S8X2C080M5PTCAHRI reference: 21810897115.208.00220002.19EPA 4574107
5PX*D010AS3+TSTAT+ furnace: S8X2C080M5PSCAHRI reference: 21810896915.208.00220002.19EPA 4574109
5PX*D010AS3+TSTAT+ furnace: S8X1C080M5PTCAHRI reference: 21810895915.208.00220002.19EPA 4574115
5PX*D010AS3+TSTAT+ furnace: *UHMD120CCV5AHRI reference: 21810895315.208.10218002.19EPA 4574121
5PX*D010AS3+TSTAT+ furnace: S9V2C100U5VSBAHRI reference: 21810894515.208.10220002.18EPA 4574129
5PX*C009AS3+TSTAT+ furnace: *UHMC100CCV4AHRI reference: 21810886915.208.00220002.18EPA 4574139
5PX*C009AS3+TSTAT+ furnace: S8X2C080M5PTCAHRI reference: 21810886115.208.00220002.18EPA 4574143
5PX*C009AS3+TSTAT+ furnace: S8X2C080M5PSCAHRI reference: 21810885915.208.00220002.18EPA 4574145
5PX*C009AS3+TSTAT+ furnace: S8X1C080M5PTCAHRI reference: 21810885315.208.00220002.18EPA 4574147
5PX*C009AS3+TSTAT+ furnace: S8X1C080M5PSCAHRI reference: 21810885115.208.00220002.18EPA 4574149
5TEMCD04AV31+TDR+TSTATAHRI reference: 21811208415.208.10218002.21EPA 4575602
5TXCD010AS3+TSTAT+ furnace: S8X1C080M5PTCAHRI reference: 21815924215.207.80220002.19EPA 4576618
5TEM4D06AC41+TDR+TSTATAHRI reference: 21815923015.207.80220002.24EPA 4576620
5PX*DD10AS3+TSTAT+ furnace: S8X1D120M5PSCAHRI reference: 21815922815.208.00222002.14EPA 4576622
5PX*D010AS3+TSTAT+ furnace: S8X1C080M5PSCAHRI reference: 21815922615.208.00220002.19EPA 4576624
5TXCD010AS3+TSTAT+ furnace: S9X2C100U5PSBAHRI reference: 21839583315.208.10222002.16EPA 4599300
5TXCD010AS3+TSTAT+ furnace: *UHMC100CCV4AHRI reference: 21839583115.208.10224002.15EPA 4599302
5TXCD010AS3+TSTAT+ furnace: S9V2D120U5VSBAHRI reference: 21839582915.208.10222002.19EPA 4599304

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →