American Standard / AIR-SOURCE HEAT PUMP

5A6H6036A1

Silver 16 · source records, page 9

371 published source records · source checked Sep 21, 2026

SEER2 range15.2–16.5BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity31,600–35,200BTU/h

Each efficiency range summarizes published EPA records for 5A6H6036A1. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 371 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16.5371 / 371
EER2 · BTU/Wh11.5–12371 / 371
HSPF2 · BTU/Wh7.8–8.5371 / 371
Cooling capacity · BTU/h31,600–35,200371 / 371
Heating capacity at 47°F / 8.3°C · BTU/h29,800–32,200371 / 371
Heating capacity at 17°F / −8.3°C · BTU/h21,000–22,200371 / 371
Heating capacity at 5°F / −15°C · BTU/h16,900–17,600371 / 371
COP at 5°F / −15°C2.23–2.49371 / 371
Equipment / loop typeHP - Split System371 / 371
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)371 / 371
Compressor stagingSingle stage371 / 371
Connected capabilityNo371 / 371

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
5PX*CD09AS3+TSTAT+ furnace: *DHMC100CCV4AHRI reference: 21839551316.008.10171002.33EPA 4599462
5PX*CD07AS3+TSTAT+ furnace: S9V2C100D4VSBAHRI reference: 21839550316.008.10175002.31EPA 4599472
5PX*CD07AS3+TSTAT+ furnace: S9V2C100D5VSBAHRI reference: 21839550116.008.10175002.31EPA 4599474
5PX*B006AS3+TSTAT+ furnace: S8X1B060M4PSCAHRI reference: 21839547116.008.10173002.35EPA 4599484
5PX*B006AS3+TSTAT+ furnace: S8X1B060M4PTCAHRI reference: 21839546916.008.10173002.35EPA 4599486
5PX*B006AS3+TSTAT+ furnace: S8X2B060M4PTCAHRI reference: 21839545716.008.10173002.35EPA 4599498
5PX*B006AS3+TSTAT+ furnace: S8X2B060M4PSCAHRI reference: 21839545516.008.10173002.35EPA 4599500
5PX*C009AS3+TSTAT+ furnace: S9X2C100U5PSBAHRI reference: 21810771715.208.10170002.39EPA 4573418
5PX*C009AS3+TSTAT+ furnace: S9X1C100U5PSBAHRI reference: 21810767515.208.10170002.39EPA 4573460
5PX*C007AS3+TSTAT+ furnace: S9X2C100U5PSBAHRI reference: 21810766315.208.10171002.38EPA 4573472
5PX*C007AS3+TSTAT+ furnace: S9X1C100U5PSBAHRI reference: 21810766115.208.10171002.38EPA 4573474
5PX*C005AS3+TSTAT+ furnace: S9V2C100U5VSBAHRI reference: 21810763315.208.10170002.33EPA 4573502
5PX*C005AS3+TSTAT+ furnace: S9X1C080U5PSBAHRI reference: 21810763115.208.10171002.33EPA 4573504
5PX*C005AS3+TSTAT+ furnace: S9V2C100U4VSBAHRI reference: 21810762915.208.10171002.31EPA 4573506
5PX*C005AS3+TSTAT+ furnace: S8X2C100M5PTCAHRI reference: 21810762715.208.10174002.31EPA 4573508
5PX*C005AS3+TSTAT+ furnace: S8X2C080M5PTCAHRI reference: 21810762515.208.10174002.32EPA 4573510
5PX*C005AS3+TSTAT+ furnace: S8X1C100M5PTCAHRI reference: 21810762315.208.10174002.31EPA 4573512
5PX*C005AS3+TSTAT+ furnace: S8X1C080M5PTCAHRI reference: 21810762115.208.10174002.32EPA 4573514
5PX*C005AS3+TSTAT+ furnace: S8V2C100M5PDBAHRI reference: 21810761915.208.10172002.32EPA 4573516
5PX*C005AS3+TSTAT+ furnace: S8V2C080M5PDBAHRI reference: 21810761715.208.10172002.32EPA 4573518

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →