SEER2 range15.2–16.5BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity31,600–35,200BTU/h

Each efficiency range summarizes published EPA records for 5A6H6036A1. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 371 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16.5371 / 371
EER2 · BTU/Wh11.5–12371 / 371
HSPF2 · BTU/Wh7.8–8.5371 / 371
Cooling capacity · BTU/h31,600–35,200371 / 371
Heating capacity at 47°F / 8.3°C · BTU/h29,800–32,200371 / 371
Heating capacity at 17°F / −8.3°C · BTU/h21,000–22,200371 / 371
Heating capacity at 5°F / −15°C · BTU/h16,900–17,600371 / 371
COP at 5°F / −15°C2.23–2.49371 / 371
Equipment / loop typeHP - Split System371 / 371
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)371 / 371
Compressor stagingSingle stage371 / 371
Connected capabilityNo371 / 371

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
5PX*CD09AS3+TSTAT+ furnace: S8X2C100M5PSCAHRI reference: 21810778916.008.10172002.32EPA 4574957 →
5PX*CD09AS3+TSTAT+ furnace: S9V2C100D4VSBAHRI reference: 21810778716.008.10170002.33EPA 4574959 →
5PX*CD09AS3+TSTAT+P0V0C000M50SDAHRI reference: 21810778516.008.10170002.38EPA 4574961 →
5PX*CD09AS3+TSTAT+ furnace: S8V2C080M5PDBAHRI reference: 21810778316.008.10173002.32EPA 4574963 →
5PX*CD09AS3+TSTAT+ furnace: S8X1C080M5PTCAHRI reference: 21810778116.008.10172002.32EPA 4574965 →
5PX*CD09AS3+TSTAT+ furnace: S9V2C100D5VSBAHRI reference: 21810777916.008.10170002.33EPA 4574967 →
5PX*CD09AS3+TSTAT+ furnace: S8X2C100M5PTCAHRI reference: 21810777716.008.10172002.32EPA 4574969 →
5PX*CD09AS3+TSTAT+ furnace: S8X2C080M5PTCAHRI reference: 21810777516.008.10172002.32EPA 4574971 →
5PX*CD09AS3+TSTAT+ furnace: S8X1C100M5PTCAHRI reference: 21810777316.008.10172002.32EPA 4574973 →
5PX*CD07AS3+TSTAT+ furnace: S8X2C080M5PSCAHRI reference: 21810777116.008.10175002.31EPA 4574975 →
5PX*CD07AS3+TSTAT+ furnace: S8X1C080M5PSCAHRI reference: 21810776716.008.10175002.31EPA 4574979 →
5PX*CD07AS3+TSTAT+ furnace: S8X1C100M5PSCAHRI reference: 21810776316.008.10176002.31EPA 4574983 →
5PX*CD07AS3+TSTAT+ furnace: S8X2C100M5PTCAHRI reference: 21810776116.008.10176002.31EPA 4574985 →
5PX*CD07AS3+TSTAT+ furnace: S8X2C100M5PSCAHRI reference: 21810775916.008.10176002.31EPA 4574987 →
5PX*CD07AS3+TSTAT+P0V0C000M50SDAHRI reference: 21810775516.008.10173002.37EPA 4574991 →
5PX*CD07AS3+TSTAT+ furnace: S8X1C080M5PTCAHRI reference: 21810775316.008.10175002.31EPA 4574993 →
5PX*CD07AS3+TSTAT+ furnace: S8X1C100M5PTCAHRI reference: 21810775116.008.10176002.31EPA 4574995 →
5PX*CD07AS3+TSTAT+ furnace: S8X2C080M5PTCAHRI reference: 21810774916.008.10175002.31EPA 4574997 →
5PX*CD09AS3+TSTAT+ furnace: S8V2C100M5PDBAHRI reference: 21815921016.008.10171002.34EPA 4576634 →
5TXCC007AS3+TSTAT+ furnace: S9V2C100U5VSBAHRI reference: 21839557516.008.10173002.36EPA 4599448 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →