American Standard / AIR-SOURCE HEAT PUMP

5A6H6036A1

Silver 16 · source records, page 14

371 published source records · source checked Sep 21, 2026

SEER2 range15.2–16.5BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity31,600–35,200BTU/h

Each efficiency range summarizes published EPA records for 5A6H6036A1. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 371 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16.5371 / 371
EER2 · BTU/Wh11.5–12371 / 371
HSPF2 · BTU/Wh7.8–8.5371 / 371
Cooling capacity · BTU/h31,600–35,200371 / 371
Heating capacity at 47°F / 8.3°C · BTU/h29,800–32,200371 / 371
Heating capacity at 17°F / −8.3°C · BTU/h21,000–22,200371 / 371
Heating capacity at 5°F / −15°C · BTU/h16,900–17,600371 / 371
COP at 5°F / −15°C2.23–2.49371 / 371
Equipment / loop typeHP - Split System371 / 371
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)371 / 371
Compressor stagingSingle stage371 / 371
Connected capabilityNo371 / 371

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
5TXCC007AS3+TSTAT+ furnace: S9X2C100U5PSBAHRI reference: 21810809315.208.10172002.39EPA 4574707
5TXCC007AS3+TSTAT+ furnace: S9X1C100U5PSBAHRI reference: 21810809115.208.10172002.39EPA 4574709
5TXCC005AS3+TSTAT+ furnace: S8X2C100M5PTCAHRI reference: 21810808715.208.10174002.31EPA 4574713
5TXCC005AS3+TSTAT+ furnace: S9X1C080U5PSBAHRI reference: 21810808515.208.10171002.33EPA 4574715
5TXCC005AS3+TSTAT+ furnace: S9X2C080U5PSBAHRI reference: 21810808315.208.10171002.33EPA 4574717
5TXCC005AS3+TSTAT+ furnace: S8X1C100M5PSCAHRI reference: 21810808115.208.10174002.31EPA 4574719
5TXCC005AS3+TSTAT+ furnace: S8X2C080M5PSCAHRI reference: 21810807915.208.10174002.32EPA 4574721
5TXCC005AS3+TSTAT+ furnace: S8X2C100M5PSCAHRI reference: 21810807715.208.10174002.31EPA 4574723
5TXCC005AS3+TSTAT+ furnace: L8V1C100U5VSBAHRI reference: 21810807515.208.10172002.33EPA 4574725
5TXCC005AS3+TSTAT+ furnace: S8V2C080M5PCBAHRI reference: 21810807315.208.00172002.32EPA 4574727
5TXCC005AS3+TSTAT+ furnace: S9V2C100U5VSBAHRI reference: 21810807115.208.10170002.33EPA 4574729
5TXCC005AS3+TSTAT+ furnace: S8V2C100M5PCBAHRI reference: 21810806515.208.00172002.32EPA 4574731
5TXCC005AS3+TSTAT+ furnace: S8X1C080M5PSCAHRI reference: 21810806315.208.10174002.32EPA 4574733
5TXCC005AS3+TSTAT+ furnace: *UHMC100CCV4AHRI reference: 21810806115.208.10170002.33EPA 4574735
5TXCC005AS3+TSTAT+ furnace: S8V2C080M5PDBAHRI reference: 21810805915.208.00172002.32EPA 4574737
5TXCC005AS3+TSTAT+ furnace: S8V2C100M5PDBAHRI reference: 21810805715.208.00172002.32EPA 4574739
5TXCC005AS3+TSTAT+ furnace: S8X1C080M5PTCAHRI reference: 21810805515.208.10174002.32EPA 4574741
5TXCC005AS3+TSTAT+ furnace: S8X1C100M5PTCAHRI reference: 21810805315.208.10174002.31EPA 4574743
5TXCC005AS3+TSTAT+ furnace: S8X2C080M5PTCAHRI reference: 21810805115.208.10174002.32EPA 4574745
5TXCC005AS3+TSTAT+ furnace: S9V2C080U5VSBAHRI reference: 21810804915.208.10170002.32EPA 4574747

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →