SEER2 range15.2–16.5BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity31,600–35,200BTU/h

Each efficiency range summarizes published EPA records for 5A6H6036A1. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 371 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16.5371 / 371
EER2 · BTU/Wh11.5–12371 / 371
HSPF2 · BTU/Wh7.8–8.5371 / 371
Cooling capacity · BTU/h31,600–35,200371 / 371
Heating capacity at 47°F / 8.3°C · BTU/h29,800–32,200371 / 371
Heating capacity at 17°F / −8.3°C · BTU/h21,000–22,200371 / 371
Heating capacity at 5°F / −15°C · BTU/h16,900–17,600371 / 371
COP at 5°F / −15°C2.23–2.49371 / 371
Equipment / loop typeHP - Split System371 / 371
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)371 / 371
Compressor stagingSingle stage371 / 371
Connected capabilityNo371 / 371

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
5PX*B004AS3+TSTAT+ furnace: S8X2B060M4PSCAHRI reference: 21810739115.208.10172002.32EPA 4573668
5PX*B004AS3+TSTAT+ furnace: S8X2A040M3PSCAHRI reference: 21810738915.207.80175002.27EPA 4573670
5PX*B004AS3+TSTAT+ furnace: S9X1B080U4PSBAHRI reference: 21810738515.207.80173002.31EPA 4573672
5PX*B004AS3+TSTAT+ furnace: S8X1B080M4PSCAHRI reference: 21810737915.208.00172002.30EPA 4573674
5PX*B004AS3+TSTAT+ furnace: S8X1B060M4PSCAHRI reference: 21810737715.208.10172002.32EPA 4573676
5PX*B004AS3+TSTAT+ furnace: S8X1A040M3PSCAHRI reference: 21810737515.207.80175002.27EPA 4573678
5PX*B004AS3+TSTAT+ furnace: *UHMB080CCV3AHRI reference: 21810736515.208.10169002.34EPA 4573680
5TXCD010AS3+TSTAT+ furnace: S9X2D120U5PSBAHRI reference: 21810820515.208.10169002.42EPA 4574595
5TXCD010AS3+TSTAT+ furnace: S9X1D120U5PSBAHRI reference: 21810820315.208.10169002.42EPA 4574597
5TXCD008AS3+TSTAT+ furnace: S9X1D120U5PSBAHRI reference: 21810817715.208.10170002.41EPA 4574623
5TXCC009AS3+TSTAT+ furnace: S9X1C100U5PSBAHRI reference: 21810813315.208.10170002.39EPA 4574667
5TXCC009AS3+TSTAT+ furnace: S9X2C100U5PSBAHRI reference: 21810813115.208.10170002.39EPA 4574669
5TXCC007AS3+TSTAT+ furnace: S8X2C100M5PSCAHRI reference: 21810812315.208.10174002.37EPA 4574677
5TXCC007AS3+TSTAT+ furnace: S8X2C080M5PSCAHRI reference: 21810812115.208.10174002.37EPA 4574679
5TXCC007AS3+TSTAT+ furnace: S8X1C100M5PSCAHRI reference: 21810811915.208.10174002.37EPA 4574681
5TXCC007AS3+TSTAT+ furnace: S8X1C080M5PSCAHRI reference: 21810811715.208.10174002.37EPA 4574683
5TXCC007AS3+TSTAT+ furnace: S8X2C100M5PTCAHRI reference: 21810810715.208.10174002.37EPA 4574693
5TXCC007AS3+TSTAT+ furnace: S8X2C080M5PTCAHRI reference: 21810810515.208.10174002.37EPA 4574695
5TXCC007AS3+TSTAT+ furnace: S8X1C100M5PTCAHRI reference: 21810810315.208.10174002.37EPA 4574697
5TXCC007AS3+TSTAT+ furnace: S8X1C080M5PTCAHRI reference: 21810810115.208.10174002.37EPA 4574699

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.