American Standard / AIR-SOURCE HEAT PUMP

5A6H6030A1

Silver 16 · source records, page 2

143 published source records · source checked Sep 21, 2026

SEER2 range15.2–16BTU/Wh
HSPF2 range7.8–8.1BTU/Wh
Cooling capacity27,000–29,200BTU/h

Each efficiency range summarizes published EPA records for 5A6H6030A1. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 143 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16143 / 143
EER2 · BTU/Wh11.7–12143 / 143
HSPF2 · BTU/Wh7.8–8.1143 / 143
Cooling capacity · BTU/h27,000–29,200143 / 143
Heating capacity at 47°F / 8.3°C · BTU/h24,800–26,800143 / 143
Heating capacity at 17°F / −8.3°C · BTU/h16,800–17,700143 / 143
Heating capacity at 5°F / −15°C · BTU/h13,100–13,800143 / 143
COP at 5°F / −15°C2.12–2.28143 / 143
Equipment / loop typeHP - Split System143 / 143
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)143 / 143
Compressor stagingSingle stage143 / 143
Connected capabilityNo143 / 143

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
5TXCC009AS3+TSTAT+ furnace: S9X1C080U5PSBAHRI reference: 21811189816.008.00132002.19EPA 4575616
5TXCC009AS3+TSTAT+ furnace: S9X2C080U5PSBAHRI reference: 21811189416.008.00132002.19EPA 4575620
5TXCC009AS3+TSTAT+ furnace: S9V2C080U5VSBAHRI reference: 21811189016.008.10134002.20EPA 4575624
5TEMCD07AV51+TDR+TSTATAHRI reference: 21811182816.008.10131002.28EPA 4575640
5TEMCD06AV41+TDR+TSTATAHRI reference: 21811182616.008.10131002.28EPA 4575642
5PX*C009AS3+TSTAT+ furnace: S9X1C080U5PSBAHRI reference: 21811177416.008.00132002.19EPA 4575660
5PX*C009AS3+TSTAT+ furnace: S9V2C100U5VSBAHRI reference: 21811177216.008.10132002.20EPA 4575662
5PX*C009AS3+TSTAT+ furnace: S9V2C100U4VSBAHRI reference: 21811177016.008.10132002.20EPA 4575664
5PX*C009AS3+TSTAT+ furnace: S9V2C080U5VSBAHRI reference: 21811176816.008.10134002.20EPA 4575666
5PX*C009AS3+TSTAT+ furnace: S9X2C080U5PSBAHRI reference: 21811176416.008.00132002.19EPA 4575670
5TXCC007AS3+TSTAT+ furnace: S9V2C100U5VSBAHRI reference: 21839540116.008.10135002.18EPA 4599508
5PX*B006AS3+TSTAT+ furnace: *UHMB080CCV3AHRI reference: 21839522716.008.00131002.19EPA 4599566
5PX*B006AS3+TSTAT+ furnace: S9X2B040U3PSBAHRI reference: 21839522516.008.10138002.12EPA 4599568
5PX*B006AS3+TSTAT+ furnace: S9X1B040U3PSBAHRI reference: 21839522316.008.10138002.12EPA 4599570
5TXCD010AS3+TSTAT+ furnace: *UHMD120CCV5AHRI reference: 21810735115.207.80131002.23EPA 4573682
5TXCC007AS3+TSTAT+ furnace: S9X2C100U5PSBAHRI reference: 21810734115.207.80134002.19EPA 4573686
5TXCC007AS3+TSTAT+ furnace: S9X1C080U5PSBAHRI reference: 21810733715.208.10134002.19EPA 4573690
5TXCC007AS3+TSTAT+ furnace: S9X2C080U5PSBAHRI reference: 21810733515.208.10134002.19EPA 4573692
5TXCC007AS3+TSTAT+ furnace: S8V2C100M5PCBAHRI reference: 21810733315.207.80133002.18EPA 4573694
5TXCC007AS3+TSTAT+ furnace: S8V2C080M5PCBAHRI reference: 21810733115.207.80135002.17EPA 4573696

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →