5A6H6030A1
Silver 16
143 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for 5A6H6030A1. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 143 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–16 | 143 / 143 |
| EER2 · BTU/Wh | 11.7–12 | 143 / 143 |
| HSPF2 · BTU/Wh | 7.8–8.1 | 143 / 143 |
| Cooling capacity · BTU/h | 27,000–29,200 | 143 / 143 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 24,800–26,800 | 143 / 143 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 16,800–17,700 | 143 / 143 |
| Heating capacity at 5°F / −15°C · BTU/h | 13,100–13,800 | 143 / 143 |
| COP at 5°F / −15°C | 2.12–2.28 | 143 / 143 |
| Equipment / loop type | HP - Split System | 143 / 143 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 143 / 143 |
| Compressor staging | Single stage | 143 / 143 |
| Connected capability | No | 143 / 143 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
5TXCD008AS3+TSTAT+ furnace: *UHMD120CCV5AHRI reference: 218107349 | 16.00 | 8.10 | 13100 | 2.21 | EPA 4573684 → |
5TXCC007AS3+TSTAT+ furnace: S9V2C080U5VSBAHRI reference: 218107339 | 16.00 | 8.10 | 13400 | 2.18 | EPA 4573688 → |
5TEMCD05AV41+TDR+TSTATAHRI reference: 218107125 | 16.00 | 8.10 | 13200 | 2.26 | EPA 4573724 → |
5TEMCD04AV31+TDR+TSTATAHRI reference: 218107123 | 16.00 | 8.10 | 13200 | 2.26 | EPA 4573726 → |
5TEM6D07AV51+TDR+TSTATAHRI reference: 218107117 | 16.00 | 8.10 | 13300 | 2.27 | EPA 4573730 → |
5TEM6D06AV41+TDR+TSTATAHRI reference: 218107115 | 16.00 | 8.10 | 13300 | 2.27 | EPA 4573732 → |
5TEM6D05AV41+TDR+TSTATAHRI reference: 218107113 | 16.00 | 8.10 | 13300 | 2.23 | EPA 4573734 → |
5TAMXD06AV41+TSTATAHRI reference: 218107099 | 16.00 | 8.00 | 13300 | 2.18 | EPA 4573746 → |
5TAMXD05AV41+TSTATAHRI reference: 218107097 | 16.00 | 8.10 | 13400 | 2.19 | EPA 4573748 → |
5PX*D008AS3+TSTAT+ furnace: *UHMD120CCV5AHRI reference: 218107083 | 16.00 | 8.10 | 13100 | 2.21 | EPA 4573752 → |
5PX*C007AS3+TSTAT+ furnace: S9V2C080U5VSBAHRI reference: 218107029 | 16.00 | 8.10 | 13400 | 2.18 | EPA 4573758 → |
5PX*C007AS3+TSTAT+ furnace: *UHMC100CCV4AHRI reference: 218107027 | 16.00 | 8.00 | 13100 | 2.21 | EPA 4573760 → |
5PX*C007AS3+TSTAT+ furnace: S9X1C080U5PSBAHRI reference: 218107025 | 16.00 | 8.00 | 13400 | 2.19 | EPA 4573762 → |
5PX*C007AS3+TSTAT+ furnace: S9V2C100U4VSBAHRI reference: 218107023 | 16.00 | 8.10 | 13200 | 2.19 | EPA 4573764 → |
5PX*C007AS3+TSTAT+ furnace: S9V2C100U5VSBAHRI reference: 218107021 | 16.00 | 8.10 | 13300 | 2.20 | EPA 4573766 → |
5PX*C007AS3+TSTAT+ furnace: S9X2C080U5PSBAHRI reference: 218107019 | 16.00 | 8.00 | 13400 | 2.19 | EPA 4573768 → |
5PX*BD06AS3+TSTAT+P0V0B000M40SDAHRI reference: 218106947 | 16.00 | 8.10 | 13300 | 2.20 | EPA 4573790 → |
5PX*B006AS3+TSTAT+P0V0B000M40SDAHRI reference: 218106873 | 16.00 | 8.10 | 13100 | 2.21 | EPA 4573806 → |
5TXCC009AS3+TSTAT+ furnace: S9V2C100U4VSBAHRI reference: 218111902 | 16.00 | 8.10 | 13200 | 2.20 | EPA 4575612 → |
5TXCC009AS3+TSTAT+ furnace: S9V2C100U5VSBAHRI reference: 218111900 | 16.00 | 8.10 | 13200 | 2.20 | EPA 4575614 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →