American Standard / AIR-SOURCE HEAT PUMP

5A6H6024A1

Silver 16 · source records, page 4

126 published source records · source checked Sep 21, 2026

SEER2 range15.2–17BTU/Wh
HSPF2 range7.8–8.1BTU/Wh
Cooling capacity23,200–24,800BTU/h

Each efficiency range summarizes published EPA records for 5A6H6024A1. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 126 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–17126 / 126
EER2 · BTU/Wh11.7–12126 / 126
HSPF2 · BTU/Wh7.8–8.1126 / 126
Cooling capacity · BTU/h23,200–24,800126 / 126
Heating capacity at 47°F / 8.3°C · BTU/h21,000–23,200126 / 126
Heating capacity at 17°F / −8.3°C · BTU/h14,300–15,000126 / 126
Heating capacity at 5°F / −15°C · BTU/h11,000–11,500126 / 126
COP at 5°F / −15°C2.12–2.28126 / 126
Equipment / loop typeHP - Split System126 / 126
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)126 / 126
Compressor stagingSingle stage126 / 126
Connected capabilityNo126 / 126

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
5PX*BD06AS3+TSTAT+ furnace: S9X1B080D4PSBAHRI reference: 21810640716.008.00113002.16EPA 4573946 →
5PX*BD06AS3+TSTAT+ furnace: S9X2B080D4PSBAHRI reference: 21810640516.008.00113002.16EPA 4573948 →
5PX*B006AS3+TSTAT+ furnace: S8X2B080M4PTCAHRI reference: 21810629716.007.80114002.16EPA 4573950 →
5PX*B006AS3+TSTAT+ furnace: S8X2B080M4PSCAHRI reference: 21810629516.007.80114002.16EPA 4573952 →
5PX*B006AS3+TSTAT+ furnace: S8X2B060M4PTCAHRI reference: 21810629316.007.80114002.18EPA 4573954 →
5PX*B006AS3+TSTAT+ furnace: S8X2B060M4PSCAHRI reference: 21810629116.007.80114002.18EPA 4573956 →
5PX*B006AS3+TSTAT+ furnace: S8X1B080M4PTCAHRI reference: 21810628916.007.80114002.16EPA 4573958 →
5PX*B006AS3+TSTAT+ furnace: S8X1B080M4PSCAHRI reference: 21810628716.007.80114002.16EPA 4573960 →
5PX*B006AS3+TSTAT+ furnace: S8X1B060M4PTCAHRI reference: 21810628516.007.80114002.18EPA 4573962 →
5PX*B006AS3+TSTAT+ furnace: S8X1B060M4PSCAHRI reference: 21810628316.007.80114002.18EPA 4573964 →
5PX*B006AS3+TSTAT+ furnace: S8V2B080M4PDBAHRI reference: 21810628116.008.00113002.17EPA 4573966 →
5PX*B006AS3+TSTAT+ furnace: S8V2B080M4PCBAHRI reference: 21810627916.008.00113002.17EPA 4573968 →
5PX*B006AS3+TSTAT+ furnace: S8V2B060M4PDBAHRI reference: 21810627716.008.00114002.16EPA 4573970 →
5PX*B006AS3+TSTAT+ furnace: S8V2B060M4PCBAHRI reference: 21810627516.008.00114002.16EPA 4573972 →
5PX*B006AS3+TSTAT+ furnace: S8V2A040M3PDBAHRI reference: 21810627316.007.80113002.17EPA 4573974 →
5PX*B006AS3+TSTAT+ furnace: S8V2A040M3PCBAHRI reference: 21810627116.007.80113002.17EPA 4573976 →
5PX*B006AS3+TSTAT+P0V0B000M40SDAHRI reference: 21810626916.007.80112002.21EPA 4573978 →
5PX*B006AS3+TSTAT+P0V0A000M30SDAHRI reference: 21810626716.007.80113002.16EPA 4573980 →
5PX*B006AS3+TSTAT+ furnace: L8V1B080U4VSBAHRI reference: 21810626516.008.00115002.15EPA 4573982 →
5PX*B006AS3+TSTAT+ furnace: L8V1A060U3VSBAHRI reference: 21810626316.007.80114002.16EPA 4573984 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →