American Standard / AIR-SOURCE HEAT PUMP

5A6H6024A1

Silver 16 · source records, page 3

126 published source records · source checked Sep 21, 2026

SEER2 range15.2–17BTU/Wh
HSPF2 range7.8–8.1BTU/Wh
Cooling capacity23,200–24,800BTU/h

Each efficiency range summarizes published EPA records for 5A6H6024A1. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 126 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–17126 / 126
EER2 · BTU/Wh11.7–12126 / 126
HSPF2 · BTU/Wh7.8–8.1126 / 126
Cooling capacity · BTU/h23,200–24,800126 / 126
Heating capacity at 47°F / 8.3°C · BTU/h21,000–23,200126 / 126
Heating capacity at 17°F / −8.3°C · BTU/h14,300–15,000126 / 126
Heating capacity at 5°F / −15°C · BTU/h11,000–11,500126 / 126
COP at 5°F / −15°C2.12–2.28126 / 126
Equipment / loop typeHP - Split System126 / 126
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)126 / 126
Compressor stagingSingle stage126 / 126
Connected capabilityNo126 / 126

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
5PX*CD07AS3+TSTAT+ furnace: *DHMC100CCV4AHRI reference: 21810646916.008.00114002.13EPA 4573902
5PX*C007AS3+TSTAT+ furnace: *UHMC100CCV4AHRI reference: 21810646316.008.10113002.20EPA 4573906
5PX*BD06AS3+TSTAT+ furnace: S9X2B060D3PSBAHRI reference: 21810645716.008.00112002.16EPA 4573908
5PX*BD06AS3+TSTAT+ furnace: S9X1B060D3PSBAHRI reference: 21810645516.008.00112002.16EPA 4573910
5PX*BD06AS3+TSTAT+ furnace: S9V2B080D4VSBAHRI reference: 21810645116.008.00112002.16EPA 4573912
5PX*BD06AS3+TSTAT+ furnace: S9V2B040D3VSBAHRI reference: 21810644716.008.00112002.17EPA 4573916
5PX*BD06AS3+TSTAT+ furnace: S8X2B060M4PTCAHRI reference: 21810644116.007.80111002.18EPA 4573918
5PX*BD06AS3+TSTAT+ furnace: S8X2B060M4PSCAHRI reference: 21810643916.007.80111002.18EPA 4573920
5PX*BD06AS3+TSTAT+ furnace: S8X1B060M4PTCAHRI reference: 21810643316.007.80111002.18EPA 4573922
5PX*BD06AS3+TSTAT+ furnace: S8X1B060M4PSCAHRI reference: 21810643116.007.80111002.18EPA 4573924
5PX*BD06AS3+TSTAT+ furnace: S8V2B080M4PDBAHRI reference: 21810642916.008.00111002.16EPA 4573926
5PX*BD06AS3+TSTAT+ furnace: S8V2B080M4PCBAHRI reference: 21810642716.008.00111002.16EPA 4573928
5PX*BD06AS3+TSTAT+ furnace: S8V2B060M4PDBAHRI reference: 21810642516.008.00112002.15EPA 4573930
5PX*BD06AS3+TSTAT+ furnace: S8V2B060M4PCBAHRI reference: 21810642316.008.00112002.15EPA 4573932
5PX*BD06AS3+TSTAT+ furnace: S8V2A040M3PDBAHRI reference: 21810642116.007.80112002.15EPA 4573934
5PX*BD06AS3+TSTAT+ furnace: S8V2A040M3PCBAHRI reference: 21810641916.007.80112002.15EPA 4573936
5PX*BD06AS3+TSTAT+P0V0B000M40SDAHRI reference: 21810641716.007.80110002.18EPA 4573938
5PX*BD06AS3+TSTAT+P0V0A000M30SDAHRI reference: 21810641516.007.80112002.15EPA 4573940
5PX*BD06AS3+TSTAT+ furnace: *DHMB080CCV3AHRI reference: 21810641316.007.80112002.15EPA 4573942
5PX*BD06AS3+TSTAT+ furnace: *DHMB060CCV3AHRI reference: 21810641116.007.80114002.13EPA 4573944

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →