5A6H5042A1
Silver 15 · source records, page 9
293 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for 5A6H5042A1. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 293 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–17 | 293 / 293 |
| EER2 · BTU/Wh | 11.7–12 | 293 / 293 |
| HSPF2 · BTU/Wh | 7.8–8.5 | 293 / 293 |
| Cooling capacity · BTU/h | 37,400–41,500 | 293 / 293 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 37,400–40,500 | 293 / 293 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 24,600–26,400 | 293 / 293 |
| Heating capacity at 5°F / −15°C · BTU/h | 18,700–20,000 | 293 / 293 |
| COP at 5°F / −15°C | 2–2.3 | 293 / 293 |
| Equipment / loop type | HP - Split System | 293 / 293 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 293 / 293 |
| Compressor staging | Single stage | 293 / 293 |
| Connected capability | No | 293 / 293 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
5TXCC009AS3+TSTAT+ furnace: S9V2C080U5PSCAHRI reference: 215566537 | 16.00 | 8.10 | 19300 | 2.10 | EPA 3650896 → |
5TXCC009AS3+TSTAT+ furnace: S9V2C100U4VSBAHRI reference: 215566539 | 16.00 | 8.10 | 19200 | 2.20 | EPA 3650898 → |
5TXCC009AS3+TSTAT+ furnace: S9V2C100U5PSCAHRI reference: 215566541 | 16.00 | 8.10 | 19200 | 2.20 | EPA 3650900 → |
5TEM6D05AV41+TDR+TSTATAHRI reference: 215610954 | 16.00 | 8.10 | 19100 | 2.20 | EPA 3651450 → |
5TEMCD04AV31+TDR+TSTATAHRI reference: 215863943 | 16.00 | 8.10 | 18800 | 2.20 | EPA 3737615 → |
5TEMCD05AV41+TDR+TSTATAHRI reference: 215863945 | 16.00 | 8.50 | 18900 | 2.20 | EPA 3737616 → |
5PX*C007AS3+TSTAT+ furnace: S9V2C080U5VSBAHRI reference: 215831507 | 16.00 | 8.10 | 19400 | 2.10 | EPA 3737700 → |
5PX*C007AS3+TSTAT+ furnace: S9V2C100U5VSBAHRI reference: 215831509 | 16.00 | 8.10 | 19200 | 2.10 | EPA 3737702 → |
5PX*C009AS3+TSTAT+ furnace: S9V2C080U5VSBAHRI reference: 215831511 | 16.00 | 8.10 | 19300 | 2.10 | EPA 3737704 → |
5PX*C009AS3+TSTAT+ furnace: S9V2C100U5VSBAHRI reference: 215831513 | 16.00 | 8.10 | 19200 | 2.20 | EPA 3737706 → |
5PX*CD09AS3+TSTAT+ furnace: S9V2C100D5VSBAHRI reference: 215831517 | 16.00 | 8.10 | 19200 | 2.10 | EPA 3737708 → |
5PX*DD10AS3+TSTAT+ furnace: S9V2D120D5VSBAHRI reference: 215831521 | 16.00 | 8.10 | 19400 | 2.10 | EPA 3737712 → |
5TXCC007AS3+TSTAT+ furnace: S9V2C080U5VSBAHRI reference: 215831533 | 16.00 | 8.10 | 19300 | 2.10 | EPA 3737718 → |
5TXCC007AS3+TSTAT+ furnace: S9V2C100U5VSBAHRI reference: 215831535 | 16.00 | 8.10 | 19200 | 2.10 | EPA 3737720 → |
5TXCC009AS3+TSTAT+ furnace: S9V2C080U5VSBAHRI reference: 215831537 | 16.00 | 8.10 | 19300 | 2.10 | EPA 3737722 → |
5TXCC009AS3+TSTAT+ furnace: S9V2C100U5VSBAHRI reference: 215831539 | 16.00 | 8.10 | 19200 | 2.20 | EPA 3737724 → |
5TAM5D06AC41+TSTATAHRI reference: 216021958 | 16.00 | 8.10 | 19100 | 2.20 | EPA 3845932 → |
5TAM5D07AC51+TSTATAHRI reference: 216021960 | 16.00 | 8.10 | 19200 | 2.10 | EPA 3845934 → |
5TAMXD05AV41+TSTATAHRI reference: 216056981 | 16.00 | 8.10 | 19100 | 2.10 | EPA 3845958 → |
5TAMXD06AV41+TSTATAHRI reference: 216056983 | 16.00 | 8.00 | 19200 | 2.10 | EPA 3845960 → |