American Standard / AIR-SOURCE HEAT PUMP

5A6H5042A1

Silver 15 · source records, page 10

293 published source records · source checked Sep 21, 2026

SEER2 range15.2–17BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity37,400–41,500BTU/h

Each efficiency range summarizes published EPA records for 5A6H5042A1. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 293 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–17293 / 293
EER2 · BTU/Wh11.7–12293 / 293
HSPF2 · BTU/Wh7.8–8.5293 / 293
Cooling capacity · BTU/h37,400–41,500293 / 293
Heating capacity at 47°F / 8.3°C · BTU/h37,400–40,500293 / 293
Heating capacity at 17°F / −8.3°C · BTU/h24,600–26,400293 / 293
Heating capacity at 5°F / −15°C · BTU/h18,700–20,000293 / 293
COP at 5°F / −15°C2–2.3293 / 293
Equipment / loop typeHP - Split System293 / 293
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)293 / 293
Compressor stagingSingle stage293 / 293
Connected capabilityNo293 / 293

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
5TAMXD07AV51+TSTATAHRI reference: 21605698516.008.00191002.10EPA 3845962
5PX*DD10AS3+TSTAT+ furnace: S8V2D120M5PCBAHRI reference: 21836375316.008.10196002.10EPA 4587076
5PX*D010AS3+TSTAT+ furnace: S8X1D120M5PSCAHRI reference: 21836375116.008.10193002.10EPA 4587078
5PX*D008AS3+TSTAT+ furnace: S8X1D120M5PSCAHRI reference: 21836374916.008.10196002.10EPA 4587080
5TXCB006AS3+TSTAT+ furnace: S9X2B080U4PSBAHRI reference: 21407881615.208.10192002.10EPA 3423916
5TXCB006AS3+TSTAT+ furnace: L8V1B080U4VSBAHRI reference: 21407881815.207.80194002.10EPA 3423918
5TXCB006AS3+TSTAT+ furnace: L9X1B070U4VSAAHRI reference: 21407882015.207.80196002.10EPA 3424135
5TXCB006AS3+TSTAT+P0V0B000M40SDAHRI reference: 21407882215.208.10193002.10EPA 3424137
5TXCB006AS3+TSTAT+ furnace: S8V2B060M4PCAAHRI reference: 21407882415.208.10193002.10EPA 3424140
5TXCB006AS3+TSTAT+ furnace: S8V2B060M4PCBAHRI reference: 21407882615.207.80193002.10EPA 3424141
5TXCB006AS3+TSTAT+ furnace: S8V2B060M4PDAAHRI reference: 21407882815.208.10193002.10EPA 3424144
5TXCB006AS3+TSTAT+ furnace: S8V2B080M4PCBAHRI reference: 21407883015.207.80193002.10EPA 3424145
5TXCB006AS3+TSTAT+ furnace: S8V2B060M4PDBAHRI reference: 21407883215.207.80193002.10EPA 3424147
5TXCB006AS3+TSTAT+ furnace: S8V2B080M4PCAAHRI reference: 21407883415.208.10194002.10EPA 3424148
5TXCB006AS3+TSTAT+ furnace: S8V2B080M4PDAAHRI reference: 21407883615.208.10194002.10EPA 3424151
5TXCB006AS3+TSTAT+ furnace: S8V2B080M4PDBAHRI reference: 21407883815.207.80193002.10EPA 3424153
5TXCB006AS3+TSTAT+ furnace: S8X1B060M4PSCAHRI reference: 21407884015.207.80192002.10EPA 3424155
5TXCB006AS3+TSTAT+ furnace: S8X1B060M4PTCAHRI reference: 21407884215.207.80192002.10EPA 3424157
5TXCB006AS3+TSTAT+ furnace: S8X1B080M4PSCAHRI reference: 21407884415.208.10193002.10EPA 3424159
5TXCB006AS3+TSTAT+ furnace: S8X1B080M4PTCAHRI reference: 21407884615.208.10193002.10EPA 3424160

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →