American Standard / AIR-SOURCE HEAT PUMP

5A6H5036A1

Silver 15 · source records, page 3

481 published source records · source checked Sep 21, 2026

SEER2 range15.2–16.5BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity31,800–35,200BTU/h

Each efficiency range summarizes published EPA records for 5A6H5036A1. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 481 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16.5481 / 481
EER2 · BTU/Wh11.7–12481 / 481
HSPF2 · BTU/Wh7.8–8.5481 / 481
Cooling capacity · BTU/h31,800–35,200481 / 481
Heating capacity at 47°F / 8.3°C · BTU/h29,800–32,800481 / 481
Heating capacity at 17°F / −8.3°C · BTU/h20,800–22,400481 / 481
Heating capacity at 5°F / −15°C · BTU/h16,600–17,800481 / 481
COP at 5°F / −15°C2.1–2.4481 / 481
Equipment / loop typeHP - Split System481 / 481
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)481 / 481
Compressor stagingSingle stage481 / 481
Connected capabilityNo481 / 481

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
5TXCC007AS3+TSTAT+ furnace: S8V2C100M5PCBAHRI reference: 21407874216.008.10172002.30EPA 3424922
5TXCC007AS3+TSTAT+ furnace: S8V2C100M5PDBAHRI reference: 21407874616.008.10172002.30EPA 3424926
5TXCC007AS3+TSTAT+ furnace: S9V2C080U5PSBAHRI reference: 21407876416.008.10172002.30EPA 3424944
5TXCC007AS3+TSTAT+ furnace: S9V2C080U5PSCAHRI reference: 21407876616.008.10172002.30EPA 3424946
5PX*CD07AS3+TSTAT+ furnace: S8X1C100M5PSCAHRI reference: 21556859716.008.10176002.20EPA 3649934
5PX*CD07AS3+TSTAT+ furnace: S8X2C080M5PSCAHRI reference: 21556859916.008.10177002.20EPA 3649937
5PX*CD07AS3+TSTAT+ furnace: S8X2C100M5PSCAHRI reference: 21556860116.008.10176002.20EPA 3649938
5PX*CD07AS3+TSTAT+ furnace: S9V2C100D5PSCAHRI reference: 21556860516.008.10174002.30EPA 3649942
5PX*CD07AS3+TSTAT+ furnace: S9V2C100D4VSBAHRI reference: 21556860716.008.10174002.30EPA 3649944
5PX*CD07AS3+TSTAT+ furnace: S8X2C100M5PTCAHRI reference: 21556860916.008.10176002.20EPA 3649946
5PX*CD07AS3+TSTAT+ furnace: S8X2C080M5PTCAHRI reference: 21556861116.008.10177002.20EPA 3649948
5PX*CD09AS3+TSTAT+ furnace: *DHMC100CCV4AHRI reference: 21556861516.008.10172002.20EPA 3649950
5PX*CD09AS3+TSTAT+ furnace: S8V2C100M5PCBAHRI reference: 21556861716.008.10174002.20EPA 3649952
5PX*CD09AS3+TSTAT+ furnace: S8V2C100M5PDBAHRI reference: 21556861916.008.10174002.20EPA 3649954
5PX*CD09AS3+TSTAT+ furnace: S8X1C080M5PSCAHRI reference: 21556862116.008.10174002.20EPA 3649956
5PX*CD09AS3+TSTAT+ furnace: S8X1C080M5PTCAHRI reference: 21556862316.008.10174002.20EPA 3649958
5PX*CD09AS3+TSTAT+ furnace: S8X1C100M5PSCAHRI reference: 21556862516.008.10173002.20EPA 3649960
5PX*CD09AS3+TSTAT+ furnace: S8V2C080M5PCBAHRI reference: 21556862716.008.10174002.20EPA 3649962
5PX*CD09AS3+TSTAT+ furnace: S8V2C080M5PDBAHRI reference: 21556863116.008.10174002.20EPA 3649966
5PX*CD09AS3+TSTAT+ furnace: S8X2C100M5PTCAHRI reference: 21556864116.008.10173002.20EPA 3649980

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →