American Standard / AIR-SOURCE HEAT PUMP

5A6H5036A1

Silver 15 · source records, page 2

481 published source records · source checked Sep 21, 2026

SEER2 range15.2–16.5BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity31,800–35,200BTU/h

Each efficiency range summarizes published EPA records for 5A6H5036A1. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 481 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16.5481 / 481
EER2 · BTU/Wh11.7–12481 / 481
HSPF2 · BTU/Wh7.8–8.5481 / 481
Cooling capacity · BTU/h31,800–35,200481 / 481
Heating capacity at 47°F / 8.3°C · BTU/h29,800–32,800481 / 481
Heating capacity at 17°F / −8.3°C · BTU/h20,800–22,400481 / 481
Heating capacity at 5°F / −15°C · BTU/h16,600–17,800481 / 481
COP at 5°F / −15°C2.1–2.4481 / 481
Equipment / loop typeHP - Split System481 / 481
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)481 / 481
Compressor stagingSingle stage481 / 481
Connected capabilityNo481 / 481

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
5TXCC007AS3+TSTAT+ furnace: S9V2C100U4VSAAHRI reference: 21407876816.008.10171002.30EPA 3424465
5TXCC007AS3+TSTAT+ furnace: S9V2C100U4VSBAHRI reference: 21407877016.008.10176002.30EPA 3424467
5TXCC007AS3+TSTAT+ furnace: S8V2C080M5PDBAHRI reference: 21407877416.008.10172002.30EPA 3424471
5TXCD010AS3+TSTAT+ furnace: S9V2D120U5VSBAHRI reference: 21407877816.008.10169002.40EPA 3424474
5TXCC007AS3+TSTAT+ furnace: S9V2C100U5PSBAHRI reference: 21407877216.008.10171002.30EPA 3424475
5TXCD010AS3+TSTAT+ furnace: S9V2D120U5VSAAHRI reference: 21407878016.008.10173002.30EPA 3424477
5TXCD010AS3+TSTAT+ furnace: S9V2D120U5PSCAHRI reference: 21407878216.008.10169002.40EPA 3424479
5TXCD010AS3+TSTAT+ furnace: S9V2D120U5PSBAHRI reference: 21407878416.008.10169002.40EPA 3424481
5TXCD010AS3+TSTAT+ furnace: S8X2D120M5PTCAHRI reference: 21407878616.008.10172002.30EPA 3424483
5TXCD010AS3+TSTAT+ furnace: S8V2D120M5PDAAHRI reference: 21407878816.008.10169002.30EPA 3424485
5TXCD010AS3+TSTAT+ furnace: S8V2D120M5PCBAHRI reference: 21407879016.008.10169002.30EPA 3424487
5TXCD010AS3+TSTAT+ furnace: S8V2D120M5PCAAHRI reference: 21407879216.008.10169002.30EPA 3424489
5TXCD010AS3+TSTAT+ furnace: *UHMD120CCV5AHRI reference: 21407879416.008.10170002.30EPA 3424491
5TXCD010AS3+TSTAT+ furnace: *UHMD120ACV5AHRI reference: 21407879616.008.10170002.30EPA 3424493
5TXCD010AS3+TSTAT+ furnace: S8X1D120M5PTCAHRI reference: 21407879816.008.10172002.30EPA 3424496
5TXCD010AS3+TSTAT+ furnace: S8X1D120M5PSCAHRI reference: 21407880016.008.10172002.30EPA 3424497
5TXCD010AS3+TSTAT+ furnace: S8X2D120M5PSCAHRI reference: 21407880416.008.10172002.30EPA 3424501
5TXCD010AS3+TSTAT+ furnace: S8V2D120M5PDBAHRI reference: 21407880616.008.10169002.30EPA 3424503
5TXCC007AS3+TSTAT+ furnace: S9X2C080U5PSBAHRI reference: 21407873616.008.10171002.30EPA 3424916
5TXCC007AS3+TSTAT+ furnace: S9X1C080U5PSBAHRI reference: 21407873816.008.10171002.30EPA 3424918

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →