American Standard / AIR-SOURCE HEAT PUMP

5A6H5036A1

Silver 15 · source records, page 19

481 published source records · source checked Sep 21, 2026

SEER2 range15.2–16.5BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity31,800–35,200BTU/h

Each efficiency range summarizes published EPA records for 5A6H5036A1. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 481 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16.5481 / 481
EER2 · BTU/Wh11.7–12481 / 481
HSPF2 · BTU/Wh7.8–8.5481 / 481
Cooling capacity · BTU/h31,800–35,200481 / 481
Heating capacity at 47°F / 8.3°C · BTU/h29,800–32,800481 / 481
Heating capacity at 17°F / −8.3°C · BTU/h20,800–22,400481 / 481
Heating capacity at 5°F / −15°C · BTU/h16,600–17,800481 / 481
COP at 5°F / −15°C2.1–2.4481 / 481
Equipment / loop typeHP - Split System481 / 481
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)481 / 481
Compressor stagingSingle stage481 / 481
Connected capabilityNo481 / 481

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
5PX*B004AS3+TSTAT+ furnace: S8X2B080M4PTCAHRI reference: 21556816915.208.00174002.20EPA 3650390
5PX*B004AS3+TSTAT+ furnace: S9V2B040U3PSCAHRI reference: 21556817115.207.80173002.20EPA 3650391
5PX*B004AS3+TSTAT+ furnace: S9V2B040U3VSBAHRI reference: 21556817315.207.80173002.20EPA 3650393
5PX*B004AS3+TSTAT+ furnace: S9V2B060U3VSBAHRI reference: 21556817515.208.10174002.20EPA 3650395
5PX*B004AS3+TSTAT+ furnace: S9V2B060U4PSCAHRI reference: 21556817715.207.80173002.20EPA 3650397
5PX*B004AS3+TSTAT+ furnace: S9V2B080U4PSCAHRI reference: 21556817915.208.10172002.20EPA 3650400
5PX*B004AS3+TSTAT+ furnace: S9V2B080U4VSBAHRI reference: 21556818115.208.10172002.20EPA 3650401
5PX*B004AS3+TSTAT+ furnace: S9X1B040U3PSBAHRI reference: 21556818315.207.80175002.20EPA 3650403
5PX*B006AS3+TSTAT+ furnace: *UHMB060CCV3AHRI reference: 21556818515.208.10174002.30EPA 3650405
5PX*B006AS3+TSTAT+ furnace: L8V1A040U3VSBAHRI reference: 21556818915.208.00167002.20EPA 3650409
5PX*B006AS3+TSTAT+ furnace: L8V1A060U3VSBAHRI reference: 21556819115.208.10168002.20EPA 3650411
5PX*B006AS3+TSTAT+ furnace: L8V1B080U4VSBAHRI reference: 21556819315.208.10174002.30EPA 3650413
5TXCB003AS3+TSTAT+ furnace: *UHMB060CCV3AHRI reference: 21556628115.208.00177002.10EPA 3650461
5TXCB003AS3+TSTAT+P0V0B000M40SDAHRI reference: 21556628915.207.80177002.10EPA 3650462
5TXCB003AS3+TSTAT+ furnace: S8X1B060M4PSCAHRI reference: 21556629715.208.00178002.10EPA 3650465
5TXCB003AS3+TSTAT+ furnace: S8X1B060M4PTCAHRI reference: 21556629915.208.00178002.10EPA 3650467
5TXCB003AS3+TSTAT+ furnace: S8X2B060M4PSCAHRI reference: 21556630515.208.00178002.10EPA 3650469
5TXCB003AS3+TSTAT+ furnace: S8X2B060M4PTCAHRI reference: 21556630715.208.00178002.10EPA 3650471
5PX*BD06AS3+TSTAT+ furnace: S8V2A040M3PCBAHRI reference: 21556833315.208.00169002.10EPA 3650533
5PX*BD06AS3+TSTAT+ furnace: S8V2A040M3PDBAHRI reference: 21556833515.208.00169002.10EPA 3650535

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →