American Standard / AIR-SOURCE HEAT PUMP

5A6H5036A1

Silver 15 · source records, page 18

481 published source records · source checked Sep 21, 2026

SEER2 range15.2–16.5BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity31,800–35,200BTU/h

Each efficiency range summarizes published EPA records for 5A6H5036A1. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 481 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16.5481 / 481
EER2 · BTU/Wh11.7–12481 / 481
HSPF2 · BTU/Wh7.8–8.5481 / 481
Cooling capacity · BTU/h31,800–35,200481 / 481
Heating capacity at 47°F / 8.3°C · BTU/h29,800–32,800481 / 481
Heating capacity at 17°F / −8.3°C · BTU/h20,800–22,400481 / 481
Heating capacity at 5°F / −15°C · BTU/h16,600–17,800481 / 481
COP at 5°F / −15°C2.1–2.4481 / 481
Equipment / loop typeHP - Split System481 / 481
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)481 / 481
Compressor stagingSingle stage481 / 481
Connected capabilityNo481 / 481

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
5PX*B006AS3+TSTAT+ furnace: S8X1A040M3PSCAHRI reference: 21556821715.208.10170002.20EPA 3650329
5PX*B006AS3+TSTAT+ furnace: S8X2A040M3PSCAHRI reference: 21556822715.208.10170002.20EPA 3650339
5PX*B006AS3+TSTAT+ furnace: S8X2A040M3PTCAHRI reference: 21556822915.208.10170002.20EPA 3650341
5PX*B006AS3+TSTAT+ furnace: S9V2B040U3PSCAHRI reference: 21556823915.208.10174002.30EPA 3650350
5PX*B006AS3+TSTAT+ furnace: S9V2B040U3VSBAHRI reference: 21556824115.208.10174002.30EPA 3650353
5PX*B006AS3+TSTAT+ furnace: S9V2B080U4PSCAHRI reference: 21556824715.208.10172002.30EPA 3650359
5PX*B006AS3+TSTAT+ furnace: S9V2B080U4VSBAHRI reference: 21556824915.208.10172002.30EPA 3650361
5PX*B006AS3+TSTAT+ furnace: S9X1B040U3PSBAHRI reference: 21556825115.208.10175002.30EPA 3650363
5PX*B006AS3+TSTAT+ furnace: S9X1B060U4PSBAHRI reference: 21556825315.208.10173002.30EPA 3650365
5PX*B006AS3+TSTAT+ furnace: S9X1B080U4PSBAHRI reference: 21556825515.208.10173002.30EPA 3650367
5PX*B006AS3+TSTAT+ furnace: S9X2B040U3PSBAHRI reference: 21556825715.208.10175002.30EPA 3650369
5PX*B006AS3+TSTAT+ furnace: S9X2B060U4PSBAHRI reference: 21556825915.208.10173002.30EPA 3650371
5PX*B006AS3+TSTAT+ furnace: S9X2B080U4PSBAHRI reference: 21556826115.208.10173002.30EPA 3650373
5PX*B004AS3+TSTAT+ furnace: S9X2B080U4PSBAHRI reference: 21556815115.207.80173002.20EPA 3650375
5PX*B004AS3+TSTAT+ furnace: S8X1B060M4PTCAHRI reference: 21556815315.208.10173002.20EPA 3650377
5PX*B004AS3+TSTAT+ furnace: S8X1B080M4PSCAHRI reference: 21556815515.208.00174002.20EPA 3650379
5PX*B004AS3+TSTAT+ furnace: S8X1B080M4PTCAHRI reference: 21556815715.208.00174002.20EPA 3650380
5PX*B004AS3+TSTAT+ furnace: S8X2B060M4PSCAHRI reference: 21556816315.208.10173002.20EPA 3650383
5PX*B004AS3+TSTAT+ furnace: S8X2B060M4PTCAHRI reference: 21556816515.208.10173002.20EPA 3650385
5PX*B004AS3+TSTAT+ furnace: S8X2B080M4PSCAHRI reference: 21556816715.208.00174002.20EPA 3650387

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →