American Standard / AIR-SOURCE HEAT PUMP

5A6H5036A1

Silver 15 · source records, page 14

481 published source records · source checked Sep 21, 2026

SEER2 range15.2–16.5BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity31,800–35,200BTU/h

Each efficiency range summarizes published EPA records for 5A6H5036A1. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 481 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16.5481 / 481
EER2 · BTU/Wh11.7–12481 / 481
HSPF2 · BTU/Wh7.8–8.5481 / 481
Cooling capacity · BTU/h31,800–35,200481 / 481
Heating capacity at 47°F / 8.3°C · BTU/h29,800–32,800481 / 481
Heating capacity at 17°F / −8.3°C · BTU/h20,800–22,400481 / 481
Heating capacity at 5°F / −15°C · BTU/h16,600–17,800481 / 481
COP at 5°F / −15°C2.1–2.4481 / 481
Equipment / loop typeHP - Split System481 / 481
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)481 / 481
Compressor stagingSingle stage481 / 481
Connected capabilityNo481 / 481

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
5TXCB006AS3+TSTAT+ furnace: S8X2B080M4PTCAHRI reference: 21407863215.208.10172002.30EPA 3424267
5TXCB006AS3+TSTAT+ furnace: S9X2B080U4PSBAHRI reference: 21407863415.208.10173002.30EPA 3424269
5TXCB006AS3+TSTAT+ furnace: L8V1A040U3VSBAHRI reference: 21407863615.207.80167002.20EPA 3424271
5TXCB006AS3+TSTAT+ furnace: L8V1A060U3VSBAHRI reference: 21407863815.208.10168002.20EPA 3424273
5TXCB006AS3+TSTAT+ furnace: S9V2B040U3PSBAHRI reference: 21407864015.208.10171002.30EPA 3424274
5TXCB006AS3+TSTAT+ furnace: S9V2B040U3PSCAHRI reference: 21407864215.208.10173002.30EPA 3424277
5TXCB006AS3+TSTAT+ furnace: L8V1B080U4VSBAHRI reference: 21407864415.208.10173002.30EPA 3424279
5TXCB006AS3+TSTAT+ furnace: L9X1B070U4VSAAHRI reference: 21407864615.207.80177002.20EPA 3424281
5TXCB006AS3+TSTAT+ furnace: S9V2B040U3VSAAHRI reference: 21407864815.208.10171002.30EPA 3424283
5TXCB006AS3+TSTAT+ furnace: S9V2B040U3VSBAHRI reference: 21407865015.208.10171002.30EPA 3424285
5TXCB006AS3+TSTAT+P0V0A000M30SDAHRI reference: 21407865215.208.10168002.20EPA 3424287
5TXCB004AS3+TSTAT+ furnace: S8V2B080M4PDBAHRI reference: 21407852815.208.10174002.20EPA 3424441
5TXCB004AS3+TSTAT+ furnace: S8X1B060M4PSCAHRI reference: 21407853015.208.10175002.20EPA 3424443
5TXCB004AS3+TSTAT+ furnace: S8X1B060M4PTCAHRI reference: 21407853215.208.10175002.20EPA 3424445
5TXCB004AS3+TSTAT+ furnace: S8X1B080M4PSCAHRI reference: 21407853415.207.80173002.20EPA 3424447
5TXCB004AS3+TSTAT+ furnace: S8X1B080M4PTCAHRI reference: 21407853615.207.80173002.20EPA 3424448
5TXCB004AS3+TSTAT+ furnace: S9X2B060U4PSBAHRI reference: 21407853815.207.80174002.20EPA 3424451
5TXCB004AS3+TSTAT+ furnace: S9X2B080U4PSBAHRI reference: 21407854015.207.80174002.20EPA 3424453
5TXCB004AS3+TSTAT+ furnace: S8X2B060M4PSCAHRI reference: 21407854215.208.10175002.20EPA 3424455
5TXCB004AS3+TSTAT+ furnace: S8X2B060M4PTCAHRI reference: 21407854415.208.10175002.20EPA 3424457

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →