American Standard / AIR-SOURCE HEAT PUMP

5A6H5036A1

Silver 15 · source records, page 13

481 published source records · source checked Sep 21, 2026

SEER2 range15.2–16.5BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity31,800–35,200BTU/h

Each efficiency range summarizes published EPA records for 5A6H5036A1. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 481 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16.5481 / 481
EER2 · BTU/Wh11.7–12481 / 481
HSPF2 · BTU/Wh7.8–8.5481 / 481
Cooling capacity · BTU/h31,800–35,200481 / 481
Heating capacity at 47°F / 8.3°C · BTU/h29,800–32,800481 / 481
Heating capacity at 17°F / −8.3°C · BTU/h20,800–22,400481 / 481
Heating capacity at 5°F / −15°C · BTU/h16,600–17,800481 / 481
COP at 5°F / −15°C2.1–2.4481 / 481
Equipment / loop typeHP - Split System481 / 481
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)481 / 481
Compressor stagingSingle stage481 / 481
Connected capabilityNo481 / 481

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
5TXCB004AS3+TSTAT+P0V0A000M30SDAHRI reference: 21407859015.207.80168002.10EPA 3424226
5TXCB004AS3+TSTAT+P0V0B000M40SDAHRI reference: 21407859215.207.80172002.20EPA 3424227
5TXCB004AS3+TSTAT+ furnace: S8V2A040M3PCBAHRI reference: 21407859415.207.80169002.10EPA 3424229
5TXCB004AS3+TSTAT+ furnace: S8V2A040M3PDBAHRI reference: 21407859615.207.80169002.10EPA 3424232
5TXCB004AS3+TSTAT+ furnace: S8V2B060M4PCAAHRI reference: 21407859815.208.10174002.20EPA 3424233
5TXCB004AS3+TSTAT+ furnace: S8V2B060M4PCBAHRI reference: 21407860015.207.80171002.20EPA 3424235
5TXCB004AS3+TSTAT+ furnace: S8V2B060M4PDAAHRI reference: 21407860215.208.10174002.20EPA 3424238
5TXCB004AS3+TSTAT+ furnace: S8V2B060M4PDBAHRI reference: 21407860415.207.80171002.20EPA 3424239
5TXCB004AS3+TSTAT+ furnace: S8V2B080M4PCBAHRI reference: 21407860615.208.10174002.20EPA 3424241
5TXCB006AS3+TSTAT+ furnace: S8X1B060M4PTCAHRI reference: 21407860815.208.10172002.30EPA 3424243
5TXCB006AS3+TSTAT+ furnace: S8X1B080M4PSCAHRI reference: 21407861015.208.10172002.30EPA 3424245
5TXCB006AS3+TSTAT+ furnace: S8X1B080M4PTCAHRI reference: 21407861215.208.10172002.30EPA 3424247
5TXCB006AS3+TSTAT+ furnace: S8X2A040M3PSCAHRI reference: 21407861415.208.10170002.20EPA 3424249
5TXCB006AS3+TSTAT+ furnace: S8X2A040M3PTCAHRI reference: 21407861615.208.10170002.20EPA 3424251
5TXCB006AS3+TSTAT+ furnace: S8X2B060M4PSCAHRI reference: 21407861815.208.10172002.30EPA 3424253
5TXCB006AS3+TSTAT+ furnace: S8X2B060M4PTCAHRI reference: 21407862015.208.10172002.30EPA 3424255
5TXCB006AS3+TSTAT+ furnace: S8X2B080M4PSCAHRI reference: 21407862215.208.10172002.30EPA 3424256
5TXCB006AS3+TSTAT+ furnace: *UHMB060ACV3AHRI reference: 21407862415.208.10172002.30EPA 3424259
5TXCB006AS3+TSTAT+ furnace: *UHMB060CCV3AHRI reference: 21407862615.208.10172002.30EPA 3424261
5TXCB006AS3+TSTAT+ furnace: *UHMB080ACV3AHRI reference: 21407862815.208.10173002.30EPA 3424263

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →