4A6V8X60A1
PLATINUM 18 · XV18I · source records, page 2
86 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for 4A6V8X60A1. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 86 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 18 | 86 / 86 |
| EER2 · BTU/Wh | 11.7–12 | 86 / 86 |
| HSPF2 · BTU/Wh | 7.8–8.5 | 86 / 86 |
| Cooling capacity · BTU/h | 52,500–54,500 | 86 / 86 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 50,000–53,500 | 86 / 86 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 48,000–51,000 | 86 / 86 |
| Heating capacity at 5°F / −15°C · BTU/h | 37,000–40,000 | 86 / 86 |
| COP at 5°F / −15°C | 1.6–1.84 | 86 / 86 |
| Equipment / loop type | HP - Split System | 86 / 86 |
| Refrigerant / source-reported GWP | R-410A (GWP:2088) | 86 / 86 |
| Compressor staging | Continuously variable | 86 / 86 |
| Connected capability | No | 86 / 86 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
4PX*CU60BS3+ furnace: S9V2C100U5PSB+RPAHRI reference: 210653227 | 18.00 | 8.20 | 39500 | 1.71 | EPA 2527105 → |
4PX*DU60BS3+ furnace: S9V2C100U5PSB+RPAHRI reference: 210653231 | 18.00 | 8.00 | 38500 | 1.67 | EPA 2527502 → |
4TXCD010DS3+ furnace: S9V2C100U5PSB+RPAHRI reference: 210653237 | 18.00 | 8.00 | 38500 | 1.67 | EPA 2527503 → |
4PX*DU60BS3+ furnace: S9V2D120U5PSB+RPAHRI reference: 208443274 | 18.00 | 8.20 | 39500 | 1.72 | EPA 2527509 → |
4PX*CU60BS3+ furnace: S9V2C080U5PSB+RPAHRI reference: 210653226 | 18.00 | 8.20 | 39500 | 1.72 | EPA 2527514 → |
4TXCD010DS3+ furnace: S9V2C080U5PSB+RPAHRI reference: 210653240 | 18.00 | 8.00 | 38000 | 1.67 | EPA 2527515 → |
4TXCC009DS3+ furnace: S9V2C080U5PSB+RPAHRI reference: 210653234 | 18.00 | 8.20 | 39500 | 1.72 | EPA 2527516 → |
4PX*DU60BS3+ furnace: S9V2C080U5PSB+RPAHRI reference: 210653232 | 18.00 | 8.00 | 38000 | 1.67 | EPA 2527517 → |
4TXCD010DS3+ furnace: S9V2D120U5VSA+RPAHRI reference: 207590213 | 18.00 | 8.20 | 39500 | 1.72 | EPA 2530964 → |
4PX*DU60BS3+P0V0C000M50SC+RPAHRI reference: 207805723 | 18.00 | 8.10 | 38000 | 1.69 | EPA 2531333 → |
4TXCC009DS3+P0V0C000M50SC+RPAHRI reference: 207805725 | 18.00 | 8.20 | 39000 | 1.73 | EPA 2531334 → |
4TXCD010DS3+P0V0C000M50SC+RPAHRI reference: 207805728 | 18.00 | 8.10 | 38000 | 1.69 | EPA 2531335 → |
4TXCD010DS3+P0V0D000M50SC+RPAHRI reference: 207805727 | 18.00 | 8.20 | 39000 | 1.75 | EPA 2531336 → |
4TXCD008DS3+P0V0D000M50SC+RPAHRI reference: 207805726 | 18.00 | 8.20 | 39500 | 1.68 | EPA 2531337 → |
TEM8B0C60V51+TDRAHRI reference: 210636946 | 18.00 | 8.50 | 37000 | 1.84 | EPA 2531338 → |
TEM8A0C48V41+TDRAHRI reference: 210636942 | 18.00 | 8.50 | 37000 | 1.84 | EPA 2531339 → |
TAMXB0C60V51AHRI reference: 210929586 | 18.00 | 8.20 | 39500 | 1.76 | EPA 2531683 → |
4PX*CD60BS3+P0V0C000M50SC+RPAHRI reference: 207805717 | 18.00 | 8.00 | 39500 | 1.67 | EPA 2531685 → |
4PX*CU60BS3+P0V0C000M50SC+RPAHRI reference: 207805719 | 18.00 | 8.20 | 39000 | 1.73 | EPA 2531686 → |
4PX*DD60BS3+P0V0D000M50SC+RPAHRI reference: 207805720 | 18.00 | 8.20 | 39500 | 1.71 | EPA 2531687 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →