American Standard / AIR-SOURCE HEAT PUMP

4A6V8X60A1

PLATINUM 18 · XV18I

86 published source records · source checked Sep 21, 2026

SEER2 range18BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity52,500–54,500BTU/h

Each efficiency range summarizes published EPA records for 4A6V8X60A1. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 86 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh1886 / 86
EER2 · BTU/Wh11.7–1286 / 86
HSPF2 · BTU/Wh7.8–8.586 / 86
Cooling capacity · BTU/h52,500–54,50086 / 86
Heating capacity at 47°F / 8.3°C · BTU/h50,000–53,50086 / 86
Heating capacity at 17°F / −8.3°C · BTU/h48,000–51,00086 / 86
Heating capacity at 5°F / −15°C · BTU/h37,000–40,00086 / 86
COP at 5°F / −15°C1.6–1.8486 / 86
Equipment / loop typeHP - Split System86 / 86
Refrigerant / source-reported GWPR-410A (GWP:2088)86 / 86
Compressor stagingContinuously variable86 / 86
Connected capabilityNo86 / 86

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
4PX*CU60BS3+ furnace: S8V2C100M5PCACold climate designationAHRI reference: 21069213718.008.20400001.78EPA 2526646
4PX*DU60BS3+ furnace: S8V2C100M5PCAAHRI reference: 21069214018.008.00390001.73EPA 2526647
4TXCD010DS3+ furnace: S8V2C100M5PCAAHRI reference: 21069214218.008.00390001.73EPA 2526648
4TXCC009DS3+ furnace: S8V2C100M5PCACold climate designationAHRI reference: 21069214118.008.20400001.78EPA 2526649
4PX*CD60BS3+ furnace: S9V2C100D5PSB+RPAHRI reference: 21065322418.007.80400001.65EPA 2526652
4TXCD008DS3+ furnace: S9V2D120U5PSB+RPAHRI reference: 21065323518.008.00400001.66EPA 2526656
4TXCD010DS3+ furnace: S9V2D120U5PSB+RPAHRI reference: 21065323818.008.20395001.72EPA 2526657
4TXCD008DS3+ furnace: S9V2D120U5VSA+RPAHRI reference: 21065323618.008.00400001.66EPA 2526662
4PX*CU60BS3+ furnace: S8V2C100M5PDACold climate designationAHRI reference: 21108149818.008.20400001.78EPA 2526665
4PX*CU60BS3+ furnace: L8V1C100U5VSA+RPAHRI reference: 20759061918.008.20395001.67EPA 2527009
4TXCC009DS3+ furnace: L8V1C100U5VSA+RPAHRI reference: 20759062018.008.20395001.67EPA 2527010
4PX*DU60BS3+ furnace: S9V2D120U5VSA+RPAHRI reference: 20759021118.008.20395001.72EPA 2527017
4PX*DU60BS3+ furnace: S8V2C100M5PDAAHRI reference: 21108150018.008.00390001.73EPA 2527077
4TXCC009DS3+ furnace: S8V2C100M5PDACold climate designationAHRI reference: 21108150218.008.20400001.78EPA 2527078
4TXCD010DS3+ furnace: S8V2C100M5PDAAHRI reference: 21108150318.008.00390001.73EPA 2527079
4TXCD010DS3+ furnace: S8V2D120M5PCAAHRI reference: 21069214318.008.20395001.83EPA 2527083
4PX*DU60BS3+ furnace: S8V2D120M5PCAAHRI reference: 21069213918.008.20395001.83EPA 2527085
4PX*DU60BS3+ furnace: S8V2D120M5PDAAHRI reference: 21108150118.008.20395001.83EPA 2527086
4TXCD010DS3+ furnace: S8V2D120M5PDAAHRI reference: 21108150418.008.20395001.83EPA 2527087
4TXCC009DS3+ furnace: S9V2C100U5PSB+RPAHRI reference: 21058912018.008.20395001.71EPA 2527103

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →