AZV7SA2410A*
AZV7SA · source records, page 3
93 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for AZV7SA2410A*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 93 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 16–19 | 93 / 93 |
| EER2 · BTU/Wh | 10.5–11 | 93 / 93 |
| HSPF2 · BTU/Wh | 8.5–8.8 | 93 / 93 |
| Cooling capacity · BTU/h | 23,200 | 93 / 93 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 23,200 | 93 / 93 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 15,800 | 93 / 93 |
| Heating capacity at 5°F / −15°C · BTU/h | 17,000 | 93 / 93 |
| COP at 5°F / −15°C | 2 | 93 / 93 |
| Equipment / loop type | HP - Split System | 93 / 93 |
| Refrigerant / source-reported GWP | R-32 (GWP:675 | Lower GWP) | 93 / 93 |
| Compressor staging | Continuously variable | 93 / 93 |
| Connected capability | No · Yes | 93 / 93 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Manufacturer specifications
These values match the manufacturer’s exact model pattern AZV7SA2410A*. They describe the unit, separately from the EPA system ratings. For electrical work, the specification sheet requires checking the installed unit’s rating plate and its full instructions.
| Specification | Value | Manufacturer evidence |
|---|---|---|
| Equipment weight | 132 lb | AZV7S S-SERIES — product specifications · page 3 ↗ |
| Maximum overcurrent protection | 25 A | AZV7S S-SERIES — product specifications · page 3 ↗ |
| Minimum circuit ampacity | 22.4 A | AZV7S S-SERIES — product specifications · page 3 ↗ |
| Shipping weight | 147 lb | AZV7S S-SERIES — product specifications · page 3 ↗ |
| Voltage / phase at 60 Hz | 208-230/1 V / phase | AZV7S S-SERIES — product specifications · page 3 ↗ |
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
CA*EA3626*3A*+ furnace: A*VT960403BNA*Cold climate designationAHRI reference: 215434055 | 19.00 | 8.60 | 17000 | 2.00 | EPA 3625415 → |
CA*EA3626*3A*+ furnace: A*VT960603BNA*Cold climate designationAHRI reference: 215434056 | 19.00 | 8.60 | 17000 | 2.00 | EPA 3625416 → |
CA*EA3626*3A*+ furnace: A*VT960803BNA*Cold climate designationAHRI reference: 215434057 | 19.00 | 8.60 | 17000 | 2.00 | EPA 3625417 → |
CA*EA3626*3A*+ furnace: A*VT960804CNA*Cold climate designationAHRI reference: 215434058 | 19.00 | 8.60 | 17000 | 2.00 | EPA 3625418 → |
CA*EA3626*3A*+ furnace: A*VT961005CNA*Cold climate designationAHRI reference: 215434059 | 19.00 | 8.60 | 17000 | 2.00 | EPA 3625419 → |
CHPEA3026*3A*+ furnace: A*VM970603BNA*Cold climate designationAHRI reference: 215434060 | 19.00 | 8.60 | 17000 | 2.00 | EPA 3625420 → |
CHPEA3026*3A*+ furnace: A*VM970803BNA*Cold climate designationAHRI reference: 215434061 | 19.00 | 8.60 | 17000 | 2.00 | EPA 3625421 → |
CHPEA3026*3A*+ furnace: A*VM970804CNA*Cold climate designationAHRI reference: 215434062 | 19.00 | 8.60 | 17000 | 2.00 | EPA 3625422 → |
CHPEA3026*3A*+ furnace: A*VM971005CNA*Cold climate designationAHRI reference: 215434063 | 19.00 | 8.60 | 17000 | 2.00 | EPA 3625423 → |
CHPEA3026*3A*+ furnace: A*VS800805CUA*Cold climate designationAHRI reference: 215434065 | 19.00 | 8.60 | 17000 | 2.00 | EPA 3625424 → |
CHPEA3026*3A*+ furnace: A*VS800604BUA*Cold climate designationAHRI reference: 215434064 | 19.00 | 8.60 | 17000 | 2.00 | EPA 3625425 → |
CHPEA3026*3A*+ furnace: A*VS960603BUA*Cold climate designationAHRI reference: 215434066 | 19.00 | 8.60 | 17000 | 2.00 | EPA 3625426 → |
CHPEA3026*3A*+ furnace: A*VS960805CUA*Cold climate designationAHRI reference: 215434067 | 19.00 | 8.60 | 17000 | 2.00 | EPA 3625427 → |
CHPEA3026*3A*+ furnace: A*VT800603B*A*Cold climate designationAHRI reference: 215434068 | 19.00 | 8.60 | 17000 | 2.00 | EPA 3625428 → |
CHPEA3026*3A*+ furnace: A*VT800604B*A*Cold climate designationAHRI reference: 215434069 | 19.00 | 8.60 | 17000 | 2.00 | EPA 3625429 → |
CHPEA3026*3A*+ furnace: A*VT800803B*A*Cold climate designationAHRI reference: 215434070 | 19.00 | 8.60 | 17000 | 2.00 | EPA 3625430 → |
CHPEA3026*3A*+ furnace: A*VT800804C*A*Cold climate designationAHRI reference: 215434071 | 19.00 | 8.60 | 17000 | 2.00 | EPA 3625431 → |
CHPEA3026*3A*+ furnace: A*VT800805C*A*Cold climate designationAHRI reference: 215434072 | 19.00 | 8.60 | 17000 | 2.00 | EPA 3625432 → |
CHPEA3026*3A*+ furnace: A*VT801005C*A*Cold climate designationAHRI reference: 215434073 | 19.00 | 8.60 | 17000 | 2.00 | EPA 3625433 → |
CHPEA3026*3A*+ furnace: A*VT960403BNA*Cold climate designationAHRI reference: 215434074 | 19.00 | 8.60 | 17000 | 2.00 | EPA 3625434 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
AZV7S S-SERIES — product specifications ↗ — Manufacturer family specification sheet; only explicitly matched model patterns receive extracted values
Collection method, revision history and known limitations →