Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 93 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 16–19 | 93 / 93 |
| EER2 · BTU/Wh | 10.5–11 | 93 / 93 |
| HSPF2 · BTU/Wh | 8.5–8.8 | 93 / 93 |
| Cooling capacity · BTU/h | 23,200 | 93 / 93 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 23,200 | 93 / 93 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 15,800 | 93 / 93 |
| Heating capacity at 5°F / −15°C · BTU/h | 17,000 | 93 / 93 |
| COP at 5°F / −15°C | 2 | 93 / 93 |
| Equipment / loop type | HP - Split System | 93 / 93 |
| Refrigerant / source-reported GWP | R-32 (GWP:675 | Lower GWP) | 93 / 93 |
| Compressor staging | Continuously variable | 93 / 93 |
| Connected capability | No · Yes | 93 / 93 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Manufacturer specifications
These values match the manufacturer’s exact model pattern AZV7SA2410A*. They describe the unit, separately from the EPA system ratings. For electrical work, the specification sheet requires checking the installed unit’s rating plate and its full instructions.
| Specification | Value | Manufacturer evidence |
|---|---|---|
| Equipment weight | 132 lb | AZV7S S-SERIES — product specifications · page 3 ↗ |
| Maximum overcurrent protection | 25 A | AZV7S S-SERIES — product specifications · page 3 ↗ |
| Minimum circuit ampacity | 22.4 A | AZV7S S-SERIES — product specifications · page 3 ↗ |
| Shipping weight | 147 lb | AZV7S S-SERIES — product specifications · page 3 ↗ |
| Voltage / phase at 60 Hz | 208-230/1 V / phase | AZV7S S-SERIES — product specifications · page 3 ↗ |
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
CA*EA3022*3A*+ furnace: A*VT801005C*A*Cold climate designationAHRI reference: 215434035 | 19.00 | 8.60 | 17000 | 2.00 | EPA 3625395 → |
CA*EA3022*3A*+ furnace: A*VT960403BNA*Cold climate designationAHRI reference: 215434036 | 19.00 | 8.60 | 17000 | 2.00 | EPA 3625396 → |
CA*EA3022*3A*+ furnace: A*VT960603BNA*Cold climate designationAHRI reference: 215434037 | 19.00 | 8.60 | 17000 | 2.00 | EPA 3625397 → |
CA*EA3022*3A*+ furnace: A*VT960803BNA*Cold climate designationAHRI reference: 215434038 | 19.00 | 8.60 | 17000 | 2.00 | EPA 3625398 → |
CA*EA3022*3A*+ furnace: A*VT960804CNA*Cold climate designationAHRI reference: 215434039 | 19.00 | 8.60 | 17000 | 2.00 | EPA 3625399 → |
CA*EA3022*3A*+ furnace: A*VT961005CNA*Cold climate designationAHRI reference: 215434040 | 19.00 | 8.60 | 17000 | 2.00 | EPA 3625400 → |
CA*EA3626*3A*+ furnace: A*VM970603BNA*Cold climate designationAHRI reference: 215434041 | 19.00 | 8.60 | 17000 | 2.00 | EPA 3625401 → |
CA*EA3626*3A*+ furnace: A*VM970803BNA*Cold climate designationAHRI reference: 215434042 | 19.00 | 8.60 | 17000 | 2.00 | EPA 3625402 → |
CA*EA3626*3A*+ furnace: A*VM970804CNA*Cold climate designationAHRI reference: 215434043 | 19.00 | 8.60 | 17000 | 2.00 | EPA 3625403 → |
CA*EA3626*3A*+ furnace: A*VM971005CNA*Cold climate designationAHRI reference: 215434044 | 19.00 | 8.60 | 17000 | 2.00 | EPA 3625404 → |
CA*EA3626*3A*+ furnace: A*VS800604BUA*Cold climate designationAHRI reference: 215434045 | 19.00 | 8.60 | 17000 | 2.00 | EPA 3625405 → |
CA*EA3626*3A*+ furnace: A*VS800805CUA*Cold climate designationAHRI reference: 215434046 | 19.00 | 8.60 | 17000 | 2.00 | EPA 3625406 → |
CA*EA3626*3A*+ furnace: A*VS960603BUA*Cold climate designationAHRI reference: 215434047 | 19.00 | 8.60 | 17000 | 2.00 | EPA 3625407 → |
CA*EA3626*3A*+ furnace: A*VS960805CUA*Cold climate designationAHRI reference: 215434048 | 19.00 | 8.60 | 17000 | 2.00 | EPA 3625408 → |
CA*EA3626*3A*+ furnace: A*VT800603B*A*Cold climate designationAHRI reference: 215434049 | 19.00 | 8.60 | 17000 | 2.00 | EPA 3625409 → |
CA*EA3626*3A*+ furnace: A*VT800604B*A*Cold climate designationAHRI reference: 215434050 | 19.00 | 8.60 | 17000 | 2.00 | EPA 3625410 → |
CA*EA3626*3A*+ furnace: A*VT800803B*A*Cold climate designationAHRI reference: 215434051 | 19.00 | 8.60 | 17000 | 2.00 | EPA 3625411 → |
CA*EA3626*3A*+ furnace: A*VT800804C*A*Cold climate designationAHRI reference: 215434052 | 19.00 | 8.60 | 17000 | 2.00 | EPA 3625412 → |
CA*EA3626*3A*+ furnace: A*VT800805C*A*Cold climate designationAHRI reference: 215434053 | 19.00 | 8.60 | 17000 | 2.00 | EPA 3625413 → |
CA*EA3626*3A*+ furnace: A*VT801005C*A*Cold climate designationAHRI reference: 215434054 | 19.00 | 8.60 | 17000 | 2.00 | EPA 3625414 → |
Sources and documentation