Q5H9V48*K*AAA*
QuietComfort 19 SEER2 VS HP · source records, page 15
507 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for Q5H9V48*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 507 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–19 | 507 / 507 |
| EER2 · BTU/Wh | 10–13.5 | 507 / 507 |
| HSPF2 · BTU/Wh | 8.5–10 | 507 / 507 |
| Cooling capacity · BTU/h | 43,500–49,500 | 507 / 507 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 46,500–55,000 | 507 / 507 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 38,500–47,000 | 507 / 507 |
| Heating capacity at 5°F / −15°C · BTU/h | 36,000–41,500 | 507 / 507 |
| COP at 5°F / −15°C | 1.95–2.32 | 507 / 507 |
| Equipment / loop type | HP - Split System | 507 / 507 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 507 / 507 |
| Compressor staging | Continuously variable | 507 / 507 |
| Connected capability | No | 507 / 507 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
EVD5X61M21A*+ furnace: *96VSN1002120B*Cold climate designationAHRI reference: 217955572 | 16.00 | 9.50 | 40500 | 2.24 | EPA 4566041 → |
ESH5X60M12A*+ furnace: *80CTL1102120B*Cold climate designationAHRI reference: 217956152 | 16.00 | 9.00 | 36600 | 2.10 | EPA 4566060 → |
ESH5X60M12A*+ furnace: *80CTL1352422B*Cold climate designationAHRI reference: 217956154 | 16.00 | 9.00 | 36600 | 2.10 | EPA 4566062 → |
ESH5X60M12A*+ furnace: *80VTL0902120B*Cold climate designationAHRI reference: 217956158 | 16.00 | 9.00 | 36600 | 2.10 | EPA 4566066 → |
ESH5X60M12A*+ furnace: *80VTL1102122B*Cold climate designationAHRI reference: 217956160 | 16.00 | 9.00 | 36600 | 2.10 | EPA 4566068 → |
ESH5X60M12A*+ furnace: *95CSU1002122B*Cold climate designationAHRI reference: 217956166 | 16.00 | 9.00 | 36600 | 2.10 | EPA 4566072 → |
ESH5X60M12A*+ furnace: *97CMN0802120B*Cold climate designationAHRI reference: 217956172 | 16.00 | 9.00 | 36800 | 2.10 | EPA 4566076 → |
ESH5X60M12A*+ furnace: *97CMN1002122B*Cold climate designationAHRI reference: 217956174 | 16.00 | 9.00 | 36800 | 2.08 | EPA 4566078 → |
ESH5X60M12A*+ furnace: *97CMN1202422B*Cold climate designationAHRI reference: 217956176 | 16.00 | 9.00 | 36800 | 2.10 | EPA 4566080 → |
ESH5X60M12A*+ furnace: *96VSN1202422B*Cold climate designationAHRI reference: 217956186 | 16.00 | 9.00 | 36800 | 2.08 | EPA 4566086 → |
ESH5X60M12A*+ furnace: *95MSU1002120A*Cold climate designationAHRI reference: 217956192 | 16.00 | 9.00 | 36800 | 2.08 | EPA 4566090 → |
ESH5X60M12A*+ furnace: *95MSU1002122A*Cold climate designationAHRI reference: 217956194 | 16.00 | 9.00 | 36600 | 2.10 | EPA 4566092 → |
ESH5X60M12A*+ furnace: *96CTN1002122B*Cold climate designationAHRI reference: 217956198 | 16.00 | 9.00 | 36800 | 2.08 | EPA 4566096 → |
EVD5X61M21A*+ furnace: *96VTN0802120B*Cold climate designationAHRI reference: 217955588 | 16.00 | 9.00 | 40500 | 2.15 | EPA 4566101 → |
EVD5X61M21A*+ furnace: *96VTN1002120B*Cold climate designationAHRI reference: 217955590 | 16.00 | 9.00 | 40500 | 2.15 | EPA 4566103 → |
EVD5X61M21A*+ furnace: *97VTN0802120A*Cold climate designationAHRI reference: 217955594 | 16.00 | 9.00 | 40500 | 2.15 | EPA 4566107 → |
EVD5X61M21A*+ furnace: *97VTN1002120A*Cold climate designationAHRI reference: 217955596 | 16.00 | 9.00 | 40500 | 2.15 | EPA 4566109 → |
EVD5X61M24A*+ furnace: *80CSU1002120B*Cold climate designationAHRI reference: 217955602 | 16.00 | 9.00 | 40500 | 2.15 | EPA 4566115 → |
EVD5X61M24A*+ furnace: *80MSU1002120A*Cold climate designationAHRI reference: 217955610 | 16.00 | 9.00 | 40500 | 2.15 | EPA 4566123 → |
EVD5X61M24A*+ furnace: *80CTL0902120B*Cold climate designationAHRI reference: 217955614 | 16.00 | 9.50 | 40500 | 2.24 | EPA 4566127 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →