Q5H9V48*K*AAA*
QuietComfort 19 SEER2 VS HP · source records, page 14
507 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for Q5H9V48*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 507 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–19 | 507 / 507 |
| EER2 · BTU/Wh | 10–13.5 | 507 / 507 |
| HSPF2 · BTU/Wh | 8.5–10 | 507 / 507 |
| Cooling capacity · BTU/h | 43,500–49,500 | 507 / 507 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 46,500–55,000 | 507 / 507 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 38,500–47,000 | 507 / 507 |
| Heating capacity at 5°F / −15°C · BTU/h | 36,000–41,500 | 507 / 507 |
| COP at 5°F / −15°C | 1.95–2.32 | 507 / 507 |
| Equipment / loop type | HP - Split System | 507 / 507 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 507 / 507 |
| Compressor staging | Continuously variable | 507 / 507 |
| Connected capability | No | 507 / 507 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
EA*5X61M24A*+ furnace: *80VSL0902120B*Cold climate designationAHRI reference: 217955944 | 16.00 | 9.00 | 37200 | 2.10 | EPA 4565948 → |
EA*5X61M24A*+ furnace: *80VSL1352422B*Cold climate designationAHRI reference: 217955948 | 16.00 | 9.00 | 37200 | 2.10 | EPA 4565952 → |
EA*5X61M24A*+ furnace: *80MSU1002120A*Cold climate designationAHRI reference: 217955950 | 16.00 | 9.00 | 37200 | 2.10 | EPA 4565954 → |
EA*5X61M24A*+ furnace: *80VTL0902120B*Cold climate designationAHRI reference: 217955960 | 16.00 | 9.00 | 37200 | 2.10 | EPA 4565962 → |
EA*5X61M24A*+ furnace: *80VTL1102122B*Cold climate designationAHRI reference: 217955962 | 16.00 | 9.00 | 37000 | 2.10 | EPA 4565964 → |
ESH5X60M12A*+ furnace: *80CSU1002120B*Cold climate designationAHRI reference: 217956128 | 16.00 | 9.00 | 36800 | 2.08 | EPA 4565976 → |
ESH5X60M12A*+ furnace: *80VSL0902120B*Cold climate designationAHRI reference: 217956132 | 16.00 | 9.00 | 36600 | 2.10 | EPA 4565980 → |
ESH5X60M12A*+ furnace: *80VSL1102122B*Cold climate designationAHRI reference: 217956134 | 16.00 | 9.00 | 36600 | 2.10 | EPA 4565982 → |
ESH5X60M12A*+ furnace: *80VSL1352422B*Cold climate designationAHRI reference: 217956136 | 16.00 | 9.00 | 36600 | 2.10 | EPA 4565984 → |
ESH5X60M12A*+ furnace: *80MSU0601716A*Cold climate designationAHRI reference: 217956138 | 16.00 | 9.00 | 36600 | 2.10 | EPA 4565986 → |
ESH5X60M12A*+ furnace: *80MSU1002120A*Cold climate designationAHRI reference: 217956142 | 16.00 | 9.00 | 36600 | 2.10 | EPA 4565990 → |
EVD5X48M21A*+ furnace: *97VTN1002122A*Cold climate designationAHRI reference: 217955420 | 16.00 | 9.50 | 39500 | 2.22 | EPA 4565995 → |
EVD5X49M24A*+ furnace: *80VSL0902120B*Cold climate designationAHRI reference: 217955424 | 16.00 | 9.00 | 40500 | 2.10 | EPA 4565999 → |
EVD5X49M24A*+ furnace: *80VSL1102122B*Cold climate designationAHRI reference: 217955426 | 16.00 | 9.00 | 40500 | 2.10 | EPA 4566001 → |
EVD5X49M24A*+ furnace: *80VSL1352422B*Cold climate designationAHRI reference: 217955428 | 16.00 | 9.00 | 40500 | 2.10 | EPA 4566003 → |
EVD5X49M24A*+ furnace: *80CTL0902120B*Cold climate designationAHRI reference: 217955432 | 16.00 | 9.00 | 40500 | 2.15 | EPA 4566007 → |
EVD5X49M24A*+ furnace: *80VTL0902120B*Cold climate designationAHRI reference: 217955434 | 16.00 | 9.00 | 40500 | 2.10 | EPA 4566009 → |
EVD5X49M24A*+ furnace: *95MSU1002122A*Cold climate designationAHRI reference: 217955448 | 16.00 | 9.00 | 40500 | 2.10 | EPA 4566023 → |
EVD5X61M21A*+ furnace: *97CMN0802120B*Cold climate designationAHRI reference: 217955566 | 16.00 | 9.00 | 41000 | 2.10 | EPA 4566035 → |
EVD5X61M21A*+ furnace: *96VSN0802120B*Cold climate designationAHRI reference: 217955570 | 16.00 | 9.00 | 40500 | 2.15 | EPA 4566039 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.