Airquest / AIR-SOURCE HEAT PUMP

H5H8T60*K*AAA*

Mainline 18 SEER2 HP · source records, page 4

85 published source records · source checked Sep 21, 2026

SEER2 range15.5–17.5BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity54,000–58,000BTU/h

Each efficiency range summarizes published EPA records for H5H8T60*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 85 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.5–17.585 / 85
EER2 · BTU/Wh11.7–1385 / 85
HSPF2 · BTU/Wh7.8–8.585 / 85
Cooling capacity · BTU/h54,000–58,00085 / 85
Heating capacity at 47°F / 8.3°C · BTU/h56,500–61,50085 / 85
Heating capacity at 17°F / −8.3°C · BTU/h36,200–38,50085 / 85
Heating capacity at 5°F / −15°C · BTU/h29,600–31,80085 / 85
COP at 5°F / −15°C2.18–2.3685 / 85
Equipment / loop typeHP - Split System85 / 85
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)85 / 85
Compressor stagingTwo-stage85 / 85
Connected capabilityNo85 / 85

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
EA*5X60M24A*+ furnace: *80VSL1102122B*AHRI reference: 21634803916.007.80298002.22EPA 3806827 →
EA*5X60M24A*+ furnace: *80VSL1352422B*AHRI reference: 21634804716.007.80296002.22EPA 3806835 →
EA*5X60M24A*+ furnace: *80MSU1002120A*AHRI reference: 21634806316.007.80296002.24EPA 3806851 →
EA*5X61M24A*+ furnace: *80VTL0902120B*AHRI reference: 21634874316.008.00300002.26EPA 3806907 →
EVD5X61M21A*+ furnace: *80VSL0902120B*AHRI reference: 21634747116.008.10310002.24EPA 3807149 →
EVD5X61M21A*+ furnace: *80MSU0802120A*AHRI reference: 21634748716.008.10306002.26EPA 3807157 →
EVD5X61M21A*+ furnace: *80MSU1002120A*AHRI reference: 21634749516.008.10310002.22EPA 3807165 →
EA*5X61M21A*+ furnace: *96VTN0802120B*AHRI reference: 21634855916.007.80304002.20EPA 3807301 →
EA*5X61M21A*+ furnace: *96VTN1002120B*AHRI reference: 21634856716.007.80302002.22EPA 3807309 →
EA*5X60M24A*+ furnace: *96VTN0802120B*AHRI reference: 21634823916.007.80300002.20EPA 3807340 →
EA*5X60M24A*+ furnace: *96VTN1002120B*AHRI reference: 21634824716.007.80298002.22EPA 3807348 →
EA*5X60M24A*+ furnace: *96VTN1002122B*AHRI reference: 21634825516.007.80296002.22EPA 3807356 →
EA*5X60M24A*+ furnace: *96VTN1202422B*AHRI reference: 21634826316.007.80300002.22EPA 3807364 →
EA*5X60M24A*+ furnace: OLV154F20AAHRI reference: 21634827116.007.80302002.18EPA 3807372 →
EA*5X60M24A*+ furnace: *96VSN1002120B*AHRI reference: 21634817515.507.80298002.20EPA 3802068 →
EVM5X61M24A*+ furnace: *80VSL0902120B*AHRI reference: 21634660715.508.50318002.32EPA 3802160 →
EVD5X60M21A*+ furnace: *80VSL0902120B*AHRI reference: 21634693515.508.10304002.22EPA 3805325 →
EVD5X60M21A*+ furnace: *80MSU0601716A*AHRI reference: 21634695115.508.10306002.24EPA 3805341 →
EVD5X60M21A*+ furnace: *80MSU1002120A*AHRI reference: 21634696715.508.10304002.24EPA 3805357 →
EVM5X60M21A*+ furnace: *95MSU1002120A*AHRI reference: 21634622315.508.10302002.24EPA 3805460 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →