Airquest / AIR-SOURCE HEAT PUMP

H5H8T60*K*AAA*

Mainline 18 SEER2 HP · source records, page 3

85 published source records · source checked Sep 21, 2026

SEER2 range15.5–17.5BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity54,000–58,000BTU/h

Each efficiency range summarizes published EPA records for H5H8T60*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 85 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.5–17.585 / 85
EER2 · BTU/Wh11.7–1385 / 85
HSPF2 · BTU/Wh7.8–8.585 / 85
Cooling capacity · BTU/h54,000–58,00085 / 85
Heating capacity at 47°F / 8.3°C · BTU/h56,500–61,50085 / 85
Heating capacity at 17°F / −8.3°C · BTU/h36,200–38,50085 / 85
Heating capacity at 5°F / −15°C · BTU/h29,600–31,80085 / 85
COP at 5°F / −15°C2.18–2.3685 / 85
Equipment / loop typeHP - Split System85 / 85
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)85 / 85
Compressor stagingTwo-stage85 / 85
Connected capabilityNo85 / 85

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
EVD5X60M21A*+ furnace: *80VSL1102122B*AHRI reference: 21634694316.008.10304002.24EPA 3805333 →
EVD5X60M21A*+ furnace: *80MSU0802120A*AHRI reference: 21634695916.008.10304002.26EPA 3805349 →
EVM5X60M21A*+ furnace: *95MSU1002122A*AHRI reference: 21634623116.008.10302002.24EPA 3805521 →
EVM5X60M21A*+ furnace: *96VTN1002122B*AHRI reference: 21634627116.008.10300002.26EPA 3805530 →
EVD5X61M24A*+ furnace: *80MSU0802120A*AHRI reference: 21634775116.008.50316002.34EPA 3805649 →
EA*5X61M21A*+ furnace: *96VSN0802120B*AHRI reference: 21634849516.007.80304002.20EPA 3805721 →
EA*5X61M21A*+ furnace: *96VSN1002120B*AHRI reference: 21634850316.007.80302002.20EPA 3805729 →
EA*5X61M21A*+ furnace: *95MSU0802120A*AHRI reference: 21634851916.007.80302002.20EPA 3805737 →
EA*5X61M21A*+ furnace: *95MSU1002120A*AHRI reference: 21634852716.007.80302002.22EPA 3805745 →
EVD5X60M21A*+ furnace: *80VTL1102122B*AHRI reference: 21634700716.008.10304002.24EPA 3805852 →
EA*5X61M24A*+ furnace: *80VSL0902120B*AHRI reference: 21634867116.007.80300002.20EPA 3806010 →
EVD5X60M21A*+ furnace: *96VTN1002122B*AHRI reference: 21634712716.008.10302002.24EPA 3806074 →
EA*5X60M24A*+ furnace: *80VTL0902120B*AHRI reference: 21634810316.007.80298002.22EPA 3806745 →
EA*5X60M24A*+ furnace: *80VTL1102122B*AHRI reference: 21634811116.007.80298002.22EPA 3806753 →
EA*5X61M24A*+ furnace: *96VSN0802120B*AHRI reference: 21634880716.007.80302002.22EPA 3806764 →
EA*5X61M24A*+ furnace: *96VSN1002120B*AHRI reference: 21634881516.007.80302002.22EPA 3806772 →
EA*5X61M24A*+ furnace: *96VSN1202422B*AHRI reference: 21634882316.007.80300002.20EPA 3806780 →
EA*5X61M24A*+ furnace: *95MSU0802120A*AHRI reference: 21634883116.007.80302002.22EPA 3806787 →
EA*5X61M24A*+ furnace: *95MSU1002120A*AHRI reference: 21634883916.007.80302002.20EPA 3806796 →
EA*5X60M24A*+ furnace: *80VSL0902120B*AHRI reference: 21634803116.007.80298002.22EPA 3806819 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →