B5H0V48*K*AAA*
Deluxe 20 VS Heat Pump · source records, page 3
327 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for B5H0V48*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 327 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.5–19.5 | 327 / 327 |
| EER2 · BTU/Wh | 9–10.5 | 327 / 327 |
| HSPF2 · BTU/Wh | 8.5–9.5 | 327 / 327 |
| Cooling capacity · BTU/h | 43,500–49,000 | 327 / 327 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 47,000–50,000 | 327 / 327 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 41,000–47,500 | 327 / 327 |
| Heating capacity at 5°F / −15°C · BTU/h | 33,000–37,600 | 327 / 327 |
| COP at 5°F / −15°C | 1.92–2.2 | 327 / 327 |
| Equipment / loop type | HP - Split System | 327 / 327 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 327 / 327 |
| Compressor staging | Continuously variable | 327 / 327 |
| Connected capability | No | 327 / 327 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
EVD5X60M21A*+WALLCON+ furnace: *97CTN0802120A*Cold climate designationAHRI reference: 218166876 | 19.00 | 9.00 | 36800 | 2.00 | EPA 4579915 → |
EVD5X60M21A*+WALLCON+ furnace: *80CSU0802120B*Cold climate designationAHRI reference: 218166867 | 19.00 | 9.00 | 36400 | 2.12 | EPA 4579924 → |
EVD5X60M21A*+WALLCON+ furnace: *96CTN0802120B*Cold climate designationAHRI reference: 218166858 | 19.00 | 9.00 | 36800 | 2.00 | EPA 4579933 → |
EVD5X49M24A*+WALLCON+ furnace: *97CTN1202422A*Cold climate designationAHRI reference: 218166855 | 19.00 | 9.00 | 36600 | 2.00 | EPA 4579936 → |
EVD5X49M24A*+WALLCON+ furnace: *97CTN1002122A*Cold climate designationAHRI reference: 218166852 | 19.00 | 9.00 | 36600 | 2.00 | EPA 4579939 → |
EVD5X49M24A*+WALLCON+ furnace: *97CTN0802120A*Cold climate designationAHRI reference: 218166849 | 19.00 | 9.00 | 36600 | 2.00 | EPA 4579942 → |
EVD5X49M24A*+WALLCON+ furnace: *80CSU0802120B*Cold climate designationAHRI reference: 218166843 | 19.00 | 9.00 | 36200 | 2.12 | EPA 4579948 → |
EVD5X49M24A*+WALLCON+ furnace: *96CTN0802120B*Cold climate designationAHRI reference: 218166840 | 19.00 | 9.00 | 36600 | 2.00 | EPA 4579951 → |
EVD5X48M24A*+WALLCON+ furnace: *97CTN1002122A*Cold climate designationAHRI reference: 218166834 | 19.00 | 9.00 | 36400 | 1.98 | EPA 4579957 → |
EVM5X61M24A*+WALLCON+ furnace: *97CTN0802120A*Cold climate designationAHRI reference: 218166789 | 19.00 | 9.50 | 36800 | 2.10 | EPA 4580002 → |
EVM5X61M24A*+WALLCON+ furnace: *80CSU1002120B*Cold climate designationAHRI reference: 218166786 | 19.00 | 9.00 | 36600 | 2.12 | EPA 4580005 → |
EVM5X61M24A*+WALLCON+ furnace: *80CSU0802120B*Cold climate designationAHRI reference: 218166783 | 19.00 | 9.00 | 36400 | 2.12 | EPA 4580008 → |
EVM5X61M24A*+WALLCON+ furnace: *96CTN0802120B*Cold climate designationAHRI reference: 218166780 | 19.00 | 9.50 | 36800 | 2.10 | EPA 4580011 → |
EVM5X60M24A*+WALLCON+ furnace: *97CTN1202422A*Cold climate designationAHRI reference: 218166777 | 19.00 | 9.00 | 36600 | 2.00 | EPA 4580014 → |
EVM5X60M24A*+WALLCON+ furnace: *97CTN1002122A*Cold climate designationAHRI reference: 218166774 | 19.00 | 9.00 | 36600 | 2.00 | EPA 4580017 → |
EVM5X60M24A*+WALLCON+ furnace: *97CTN0802120A*Cold climate designationAHRI reference: 218166771 | 19.00 | 9.00 | 36600 | 2.00 | EPA 4580020 → |
EVM5X60M24A*+WALLCON+ furnace: *80CSU0802120B*Cold climate designationAHRI reference: 218166765 | 19.00 | 9.00 | 36200 | 2.12 | EPA 4580026 → |
EVM5X60M24A*+WALLCON+ furnace: *96CTN0802120B*Cold climate designationAHRI reference: 218166762 | 19.00 | 9.00 | 36600 | 2.00 | EPA 4580029 → |
EVM5X60M21A*+WALLCON+ furnace: *97CTN1002122A*Cold climate designationAHRI reference: 218166759 | 19.00 | 9.00 | 36800 | 2.00 | EPA 4580032 → |
EVM5X60M21A*+WALLCON+ furnace: *97CTN0802120A*Cold climate designationAHRI reference: 218166756 | 19.00 | 9.00 | 36800 | 2.00 | EPA 4580035 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →