B5H0V48*K*AAA*
Deluxe 20 VS Heat Pump · source records, page 2
327 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for B5H0V48*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 327 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.5–19.5 | 327 / 327 |
| EER2 · BTU/Wh | 9–10.5 | 327 / 327 |
| HSPF2 · BTU/Wh | 8.5–9.5 | 327 / 327 |
| Cooling capacity · BTU/h | 43,500–49,000 | 327 / 327 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 47,000–50,000 | 327 / 327 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 41,000–47,500 | 327 / 327 |
| Heating capacity at 5°F / −15°C · BTU/h | 33,000–37,600 | 327 / 327 |
| COP at 5°F / −15°C | 1.92–2.2 | 327 / 327 |
| Equipment / loop type | HP - Split System | 327 / 327 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 327 / 327 |
| Compressor staging | Continuously variable | 327 / 327 |
| Connected capability | No | 327 / 327 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
EVM5X61M24A*+WALLCON+ furnace: *80CTL1102120B*Cold climate designationAHRI reference: 218166309 | 19.50 | 9.50 | 36600 | 2.10 | EPA 4580464 → |
EVM5X61M24A*+WALLCON+ furnace: *80CTL0902120B*Cold climate designationAHRI reference: 218166306 | 19.50 | 9.50 | 36600 | 2.10 | EPA 4580467 → |
FCMA5B60L0D*+WALLCONCold climate designationAHRI reference: 218166150 | 19.50 | 9.50 | 33000 | 2.20 | EPA 4597184 → |
FCMA5B48L0C*+WALLCONCold climate designationAHRI reference: 218165880 | 19.00 | 9.00 | 33600 | 2.10 | EPA 4579093 → |
EVD5X61M24A*+WALLCON+ furnace: *97CTN0802120A*Cold climate designationAHRI reference: 218166933 | 19.00 | 9.50 | 36800 | 2.10 | EPA 4579858 → |
EVD5X61M24A*+WALLCON+ furnace: *80CSU1002120B*Cold climate designationAHRI reference: 218166930 | 19.00 | 9.00 | 36600 | 2.12 | EPA 4579861 → |
EVD5X61M24A*+WALLCON+ furnace: *80CSU0802120B*Cold climate designationAHRI reference: 218166927 | 19.00 | 9.00 | 36400 | 2.12 | EPA 4579864 → |
EVD5X61M24A*+WALLCON+ furnace: *96CTN0802120B*Cold climate designationAHRI reference: 218166924 | 19.00 | 9.50 | 36800 | 2.10 | EPA 4579867 → |
EVD5X61M21A*+WALLCON+ furnace: *97CTN0802120A*Cold climate designationAHRI reference: 218166918 | 19.00 | 9.00 | 36800 | 2.00 | EPA 4579873 → |
EVD5X61M21A*+WALLCON+ furnace: *80CSU1002120B*Cold climate designationAHRI reference: 218166912 | 19.00 | 9.00 | 36800 | 2.12 | EPA 4579879 → |
EVD5X61M21A*+WALLCON+ furnace: *80CSU0802120B*Cold climate designationAHRI reference: 218166909 | 19.00 | 9.00 | 36600 | 2.12 | EPA 4579882 → |
EVD5X61M21A*+WALLCON+ furnace: *80CSU0601716B*Cold climate designationAHRI reference: 218166906 | 19.00 | 9.00 | 36800 | 2.10 | EPA 4579885 → |
EVD5X61M21A*+WALLCON+ furnace: *80CSU0401712B*Cold climate designationAHRI reference: 218166903 | 19.00 | 9.00 | 36800 | 2.12 | EPA 4579888 → |
EVD5X61M21A*+WALLCON+ furnace: *96CTN0802120B*Cold climate designationAHRI reference: 218166900 | 19.00 | 9.00 | 36800 | 2.00 | EPA 4579891 → |
EVD5X60M24A*+WALLCON+ furnace: *97CTN1202422A*Cold climate designationAHRI reference: 218166897 | 19.00 | 9.00 | 36600 | 2.00 | EPA 4579894 → |
EVD5X60M24A*+WALLCON+ furnace: *97CTN1002122A*Cold climate designationAHRI reference: 218166894 | 19.00 | 9.00 | 36600 | 2.00 | EPA 4579897 → |
EVD5X60M24A*+WALLCON+ furnace: *97CTN0802120A*Cold climate designationAHRI reference: 218166891 | 19.00 | 9.00 | 36600 | 2.00 | EPA 4579900 → |
EVD5X60M24A*+WALLCON+ furnace: *80CSU0802120B*Cold climate designationAHRI reference: 218166885 | 19.00 | 9.00 | 36200 | 2.12 | EPA 4579906 → |
EVD5X60M24A*+WALLCON+ furnace: *96CTN0802120B*Cold climate designationAHRI reference: 218166882 | 19.00 | 9.00 | 36600 | 2.00 | EPA 4579909 → |
EVD5X60M21A*+WALLCON+ furnace: *97CTN1002122A*Cold climate designationAHRI reference: 218166879 | 19.00 | 9.00 | 36600 | 2.00 | EPA 4579912 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →