Each efficiency range summarizes published EPA records for A7SCP18V36P-**A. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 216 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–19 | 216 / 216 |
| EER2 · BTU/Wh | 10–12 | 216 / 216 |
| HSPF2 · BTU/Wh | 8.1–9.6 | 216 / 216 |
| Cooling capacity · BTU/h | 32,200–36,000 | 216 / 216 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 34,000–38,500 | 216 / 216 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 27,000–29,600 | 216 / 216 |
| Heating capacity at 5°F / −15°C · BTU/h | 28,000–30,800 | 216 / 216 |
| COP at 5°F / −15°C | 1.8–1.95 | 216 / 216 |
| Equipment / loop type | HP - Split System | 216 / 216 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 216 / 216 |
| Compressor staging | Continuously variable | 216 / 216 |
| Connected capability | No | 216 / 216 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
7EH36BX-**+TDR+ furnace: A93UH1E045B12A*Cold climate designationAHRI reference: 217450182 | 17.35 | 8.50 | 28600 | 1.85 | EPA 4045718 → |
7EH36CX-**+TDR+ furnace: A93UH1E090C16A*Cold climate designationAHRI reference: 217450191 | 17.35 | 9.00 | 28200 | 1.90 | EPA 4046109 → |
7ED30/36BX-***+TDR+ furnace: A96DF1E045B12S*Cold climate designationAHRI reference: 218114559 | 17.35 | 8.50 | 28400 | 1.85 | EPA 4573216 → |
7EH30BX-**+TDR+ furnace: A97US2V045B12S*Cold climate designationAHRI reference: 216769696 | 17.30 | 8.50 | 28400 | 1.85 | EPA 3983624 → |
7E[C,U]30BX-**+TDR+ furnace: A97US2V070B12S*Cold climate designationAHRI reference: 216769682 | 17.30 | 8.50 | 28400 | 1.85 | EPA 3983665 → |
7EH36BX-**+TDR+ furnace: A97US2V045B12S*Cold climate designationAHRI reference: 216769704 | 17.30 | 8.50 | 28400 | 1.85 | EPA 3983762 → |
7ED30/36BX-**+TDR+ furnace: A80DF1E070B12*Cold climate designationAHRI reference: 217188761 | 17.30 | 8.50 | 28400 | 1.85 | EPA 4006968 → |
7E[C,U]36BX-**+TDR+ furnace: A80DF1E090B16*Cold climate designationAHRI reference: 217188723 | 17.30 | 8.50 | 28200 | 1.90 | EPA 4007204 → |
7E[C,U]30AX-**+TDR+ furnace: A80UH2E070A12*Cold climate designationAHRI reference: 217188694 | 17.30 | 8.50 | 28600 | 1.85 | EPA 4008135 → |
7E[C,U]30BX-**+TDR+ furnace: A97UH2E070B12S*Cold climate designationAHRI reference: 217450147 | 17.30 | 8.50 | 28600 | 1.80 | EPA 4046095 → |
7ED30/36BX-***+TDR+ furnace: A80DF1E070B12*Cold climate designationAHRI reference: 218114555 | 17.30 | 8.50 | 28400 | 1.85 | EPA 4573220 → |
7E[C,U]30BX-**+TDR+ furnace: A96UH1E070B12S*Cold climate designationAHRI reference: 217188701 | 17.25 | 8.50 | 28600 | 1.80 | EPA 4006988 → |
7ED30/36BX-**+TDR+ furnace: A97DF2E070B16S*Cold climate designationAHRI reference: 217450198 | 17.25 | 8.50 | 28800 | 1.85 | EPA 4045918 → |
7ED30/36BX-***+TDR+ furnace: A97DF2E070B16S*Cold climate designationAHRI reference: 218114573 | 17.25 | 8.50 | 28800 | 1.85 | EPA 4573202 → |
7ED42BX-**+TDR+ furnace: A97DS2V070B16S*Cold climate designationAHRI reference: 216769714 | 17.20 | 8.50 | 28600 | 1.90 | EPA 3983573 → |
7EH30BX-**+TDR+ furnace: A80DF1E090B16*Cold climate designationAHRI reference: 217188740 | 17.20 | 8.50 | 28400 | 1.85 | EPA 4006917 → |
7EH36CX-**+TDR+ furnace: A96UH1E090C16S*Cold climate designationAHRI reference: 217188760 | 17.20 | 9.00 | 28200 | 1.90 | EPA 4006967 → |
7E[C,U]30BX-**+TDR+ furnace: A80US2V080B16X*Cold climate designationAHRI reference: 217450152 | 17.20 | 8.50 | 28600 | 1.80 | EPA 4045814 → |
7EH36CX-**+TDR+ furnace: A97UH2E090C16S*Cold climate designationAHRI reference: 217450188 | 17.20 | 9.00 | 28200 | 1.90 | EPA 4046605 → |
7E[C,U]36CX-**+TDR+ furnace: A93UH1E090C16A*Cold climate designationAHRI reference: 218082971 | 17.20 | 8.50 | 28400 | 1.85 | EPA 4569949 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.