A7SCP18V36P-**A
A7SCP18V Series · source records, page 7
216 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for A7SCP18V36P-**A. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 216 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–19 | 216 / 216 |
| EER2 · BTU/Wh | 10–12 | 216 / 216 |
| HSPF2 · BTU/Wh | 8.1–9.6 | 216 / 216 |
| Cooling capacity · BTU/h | 32,200–36,000 | 216 / 216 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 34,000–38,500 | 216 / 216 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 27,000–29,600 | 216 / 216 |
| Heating capacity at 5°F / −15°C · BTU/h | 28,000–30,800 | 216 / 216 |
| COP at 5°F / −15°C | 1.8–1.95 | 216 / 216 |
| Equipment / loop type | HP - Split System | 216 / 216 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 216 / 216 |
| Compressor staging | Continuously variable | 216 / 216 |
| Connected capability | No | 216 / 216 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
7E[C,U]30BX-**+TDR+ furnace: A98USMV070B12S*Cold climate designationAHRI reference: 217188699 | 17.45 | 8.50 | 28400 | 1.85 | EPA 4008140 → |
7E[C,U]36CX-**+TDR+ furnace: A80UH2E110C16*Cold climate designationAHRI reference: 218082953 | 17.45 | 8.50 | 28000 | 1.90 | EPA 4569967 → |
7EH30BX-**+TDR+ furnace: A97US2V060B12X*Cold climate designationAHRI reference: 216769694 | 17.40 | 8.50 | 28400 | 1.85 | EPA 3983622 → |
7E[C,U]36AX-**+TDR+ furnace: A80US2V070A12*Cold climate designationAHRI reference: 217188707 | 17.40 | 8.50 | 28400 | 1.85 | EPA 4007009 → |
7E[C,U]36BX-**+TDR+ furnace: A96UH1E045B12S*Cold climate designationAHRI reference: 217188717 | 17.40 | 8.50 | 28400 | 1.85 | EPA 4007064 → |
7EH30AX-**+TDR+ furnace: A80US2V070A12*Cold climate designationAHRI reference: 217188724 | 17.40 | 9.00 | 28400 | 1.90 | EPA 4007205 → |
7EH36BX-**+TDR+ furnace: A96UH1E045B12S*Cold climate designationAHRI reference: 217188751 | 17.40 | 8.50 | 28400 | 1.85 | EPA 4007395 → |
7E[C,U]30BX-**+TDR+ furnace: A93UH1E070B12A*Cold climate designationAHRI reference: 217450150 | 17.40 | 8.50 | 28600 | 1.80 | EPA 4045812 → |
7E[C,U]36AX-**+TDR+ furnace: A80US2V070A12L*Cold climate designationAHRI reference: 217450153 | 17.40 | 8.50 | 28400 | 1.85 | EPA 4045815 → |
7ED30/36BX-**+TDR+ furnace: A93DF1E070B12A*Cold climate designationAHRI reference: 217450196 | 17.40 | 8.50 | 28600 | 1.85 | EPA 4045916 → |
7EH30AX-**+TDR+ furnace: A80US2V070A12L*Cold climate designationAHRI reference: 217450164 | 17.40 | 9.00 | 28400 | 1.90 | EPA 4045926 → |
7EH30BX-**+TDR+ furnace: A93UH1E045B12A*Cold climate designationAHRI reference: 217450171 | 17.40 | 8.50 | 28600 | 1.85 | EPA 4045934 → |
7E[C,U]30BX-**+TDR+ furnace: A97UH2E045B12S*Cold climate designationAHRI reference: 217450146 | 17.40 | 8.50 | 28800 | 1.80 | EPA 4046094 → |
7ED30/36BX-***+TDR+ furnace: A93DF1E070B12A*Cold climate designationAHRI reference: 218114569 | 17.40 | 8.50 | 28600 | 1.85 | EPA 4573206 → |
7E[C,U]30BX-**+TDR+ furnace: A97US2V040B12X*Cold climate designationAHRI reference: 216769676 | 17.35 | 8.50 | 28600 | 1.80 | EPA 3983582 → |
7EH36BX-**+TDR+ furnace: A97US2V060B12X*Cold climate designationAHRI reference: 216769702 | 17.35 | 8.50 | 28400 | 1.85 | EPA 3983760 → |
7E[C,U]36BX-**+TDR+ furnace: A97US2V045B12S*Cold climate designationAHRI reference: 216769688 | 17.35 | 8.50 | 28400 | 1.85 | EPA 3983782 → |
7ED30/36BX-**+TDR+ furnace: A96DF1E045B12S*Cold climate designationAHRI reference: 217188763 | 17.35 | 8.50 | 28400 | 1.85 | EPA 4007007 → |
7E[C,U]30AX-**+TDR+ furnace: A80US2V060A12X*Cold climate designationAHRI reference: 217188691 | 17.35 | 8.50 | 28600 | 1.85 | EPA 4007116 → |
7EH30BX-**+TDR+ furnace: A96UH1E045B12S*Cold climate designationAHRI reference: 217188734 | 17.35 | 8.50 | 28400 | 1.85 | EPA 4007320 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.