AIREASE / AIR-SOURCE HEAT PUMP

4SHP17LE148P-**A

4HSP17LE Series · 4SHP17LE SERIES · 4SHP17LE Series · 4SHP17LE1 Series · source records, page 6

226 published source records · source checked Sep 21, 2026

SEER2 range15.2–15.8BTU/Wh
HSPF2 range8–8.5BTU/Wh
Cooling capacity46,000–48,000BTU/h

Each efficiency range summarizes published EPA records for 4SHP17LE148P-**A. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 226 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–15.8226 / 226
EER2 · BTU/Wh12.5–13226 / 226
HSPF2 · BTU/Wh8–8.5226 / 226
Cooling capacity · BTU/h46,000–48,000226 / 226
Heating capacity at 47°F / 8.3°C · BTU/h44,500–47,000226 / 226
Heating capacity at 17°F / −8.3°C · BTU/h30,000–31,800226 / 226
Heating capacity at 5°F / −15°C · BTU/h24,200–26,000226 / 226
COP at 5°F / −15°C2.16–2.38226 / 226
Equipment / loop typeHP - Split System226 / 226
Refrigerant / source-reported GWPR-410A (GWP:2088)226 / 226
Compressor stagingSingle stage226 / 226
Connected capabilityNo226 / 226

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
EAC4X60C+TDR+ furnace: A97US2V080C16XAHRI reference: 21166326515.208.30256002.34EPA 2456768 →
EAC4X60C+TDR+ furnace: A97US2V080C20XAHRI reference: 21166326615.208.10256002.34EPA 2456769 →
EAC4X48C+TDR+ furnace: A96UH1E110C20AHRI reference: 21166322315.208.10242002.18EPA 2456788 →
EAC4X60C+TDR+ furnace: A97USMV090C12AHRI reference: 21166326715.208.10252002.36EPA 2456790 →
EAC4X48C+TDR+ furnace: A97USMV090C12AHRI reference: 21166322615.208.00244002.18EPA 2456793 →
EAC4X60C+TDR+ furnace: A93UH1E090C16AHRI reference: 21166325515.208.10252002.34EPA 2456805 →
EAC4X49C+TDR+ furnace: A80US2V090C20AHRI reference: 21166323915.208.10256002.26EPA 2456826 →
EAC4X49C+TDR+ furnace: A80US2V110C20LAHRI reference: 21166324215.208.10256002.26EPA 2456828 →
EAC4X49C+TDR+ furnace: A80US2V110C20AHRI reference: 21166324115.208.10256002.26EPA 2456829 →
EAC4X49C+TDR+ furnace: A97USMV090C12AHRI reference: 21166324315.208.10250002.22EPA 2456830 →
EAC4X50/60C+TDR+ furnace: A80UH1E090C20AHRI reference: 21166324515.208.00242002.18EPA 2456831 →
EAC4X50/60C+TDR+ furnace: A80US2V080C20XAHRI reference: 21166324615.208.10244002.20EPA 2456832 →
EAC4X50/60C+TDR+ furnace: A80UH2E110C20AHRI reference: 21166324415.208.10242002.18EPA 2456833 →
EA(C;U)1P48B+TDR+TXV+ furnace: A96UH1E110C20AHRI reference: 21032971015.208.10242002.18EPA 2457273 →
EA(C;U)1P60C+TDR+TXV+ furnace: A97US2V080C20XAHRI reference: 21032974715.208.10256002.34EPA 2457299 →
EA(C;U)1P49C+TDR+TXV+ furnace: A97USMV090C12AHRI reference: 21032973515.208.10250002.22EPA 2457472 →
BCE5V48M*4XAHRI reference: 21032970315.208.30242002.28EPA 2457491 →
EA(C;U)1P60C+TDR+TXV+ furnace: A97US2V080C16XAHRI reference: 21032975415.208.30256002.34EPA 2457496 →
EA(C;U)1P49C+TDR+TXV+ furnace: A93UH1E110C16AHRI reference: 21032972515.208.10254002.22EPA 2457732 →
EA(C;U)1P60C+TDR+TXV+ furnace: A97USMV090C12AHRI reference: 21032975615.208.10252002.36EPA 2457754 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.