AIREASE / AIR-SOURCE HEAT PUMP

4SHP17LE148P-**A

4HSP17LE Series · 4SHP17LE SERIES · 4SHP17LE Series · 4SHP17LE1 Series · source records, page 5

226 published source records · source checked Sep 21, 2026

SEER2 range15.2–15.8BTU/Wh
HSPF2 range8–8.5BTU/Wh
Cooling capacity46,000–48,000BTU/h

Each efficiency range summarizes published EPA records for 4SHP17LE148P-**A. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 226 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–15.8226 / 226
EER2 · BTU/Wh12.5–13226 / 226
HSPF2 · BTU/Wh8–8.5226 / 226
Cooling capacity · BTU/h46,000–48,000226 / 226
Heating capacity at 47°F / 8.3°C · BTU/h44,500–47,000226 / 226
Heating capacity at 17°F / −8.3°C · BTU/h30,000–31,800226 / 226
Heating capacity at 5°F / −15°C · BTU/h24,200–26,000226 / 226
COP at 5°F / −15°C2.16–2.38226 / 226
Equipment / loop typeHP - Split System226 / 226
Refrigerant / source-reported GWPR-410A (GWP:2088)226 / 226
Compressor stagingSingle stage226 / 226
Connected capabilityNo226 / 226

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
7EC48CX-0*+TDR+ furnace: A93UH1E110C20AHRI reference: 21471603815.408.10244002.18EPA 3489894
7EC60CX-0*+TDR+ furnace: A80US2V110C20AHRI reference: 21471612715.408.30254002.32EPA 3489896
7EC60CX-0*+TDR+ furnace: A80US2V110C20LAHRI reference: 21471612815.408.30254002.32EPA 3489898
7EC48CX-0*+TDR+ furnace: A80US2V080C20XAHRI reference: 21471604115.408.10244002.24EPA 3489928
7EH51CX-0*+TDR+ furnace: A80UH2E110C20AHRI reference: 21471597715.408.30254002.28EPA 3489930
7EC60CX-0*+TDR+ furnace: A97UH2E110C20AHRI reference: 21471611415.408.10254002.38EPA 3489937
7EC60CX-0*+TDR+ furnace: A80UH1E110C20AHRI reference: 21471611815.408.30254002.34EPA 3489941
7EC60CX-0*+TDR+ furnace: A93UH1E110C16AHRI reference: 21471612015.408.10252002.36EPA 3489942
7EH51CX-0*+TDR+ furnace: A93UH1E110C16AHRI reference: 21471598715.408.30256002.32EPA 3489948
7EH51CX-0*+TDR+ furnace: A96UH1E110C20AHRI reference: 21471598915.408.30254002.28EPA 3489951
7EH51CX-0*+TDR+ furnace: A80US2V100C20XAHRI reference: 21471599215.408.30256002.30EPA 3489955
7EC49CX-0*+TDR+ furnace: A93UH1E110C20AHRI reference: 21471606615.408.10250002.24EPA 3489957
7EC49CX-0*+TDR+ furnace: A80US2V100C20XAHRI reference: 21471607115.408.10254002.26EPA 3489964
7EC49CX-0*+TDR+ furnace: A80UH2E110C16AHRI reference: 21471605315.408.10254002.26EPA 3491685
BCE7S48M*4XAHRI reference: 21032970515.208.50244002.28EPA 2455776
EA(C;U)1P49C+TDR+TXV+ furnace: A96UH1E110C20AHRI reference: 21032972115.208.10254002.26EPA 2456080
EA(C;U)1P49C+TDR+TXV+ furnace: A80US2V090C20AHRI reference: 21032973115.208.10256002.26EPA 2456097
EA(C;U)1P60C+TDR+TXV+ furnace: A93UH1E090C16AHRI reference: 21032974215.208.10252002.34EPA 2456109
EA(C;U)1P50/60C+TDR+TXV+ furnace: A80US2V080C20XAHRI reference: 21032975915.208.10244002.20EPA 2456493
EAC4X48C+TDR+ furnace: A93UH1E110C16AHRI reference: 21166322115.208.10244002.18EPA 2456765

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.