AIREASE / AIR-SOURCE HEAT PUMP

4SHP17LE130P-**A

4HSP17LE Series · 4SHP17 SERIES · 4SHP17L SERIES · 4SHP17LE SERIES · 4SHP17LE Series · 4SHP17LE1 Series · source records, page 5

333 published source records · source checked Sep 21, 2026

SEER2 range15.2–16.2BTU/Wh
HSPF2 range7.8–8.6BTU/Wh
Cooling capacity28,200–30,600BTU/h

Each efficiency range summarizes published EPA records for 4SHP17LE130P-**A. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 333 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16.2333 / 333
EER2 · BTU/Wh12.2–13.5333 / 333
HSPF2 · BTU/Wh7.8–8.6333 / 333
Cooling capacity · BTU/h28,200–30,600333 / 333
Heating capacity at 47°F / 8.3°C · BTU/h26,600–30,000333 / 333
Heating capacity at 17°F / −8.3°C · BTU/h17,200–19,600333 / 333
Heating capacity at 5°F / −15°C · BTU/h13,200–15,400333 / 333
COP at 5°F / −15°C1.96–2.38333 / 333
Equipment / loop typeHP - Split System333 / 333
Refrigerant / source-reported GWPR-410A (GWP:2088)333 / 333
Compressor stagingSingle stage333 / 333
Connected capabilityNo333 / 333

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
7EC30AX-0*+TDR+ furnace: A80US2V060A12XAHRI reference: 21471547516.008.10143002.24EPA 3489501
7EC30BX-0*+TDR+ furnace: A80UH1E090B16AHRI reference: 21471548616.008.00142002.22EPA 3489592
7EC30BX-0*+TDR+ furnace: A80UH2E090B16AHRI reference: 21471548016.008.00142002.22EPA 3489679
7EC36BX-0*+TDR+ furnace: A80UH1E070B12AHRI reference: 21471551716.008.10143002.26EPA 3489726
7EC36BX-0*+TDR+ furnace: A93UH1E070B12AHRI reference: 21471552116.008.10144002.28EPA 3489730
7EC30BX-0*+TDR+ furnace: A80US2V090B12AHRI reference: 21471549416.008.10143002.20EPA 3489795
7EC36BX-0*+TDR+ furnace: A97US2V070B12S*AHRI reference: 21471551616.008.10145002.28EPA 3489825
7EH30BX-0*+TDR+ furnace: A93UH1E070B12AHRI reference: 21471541716.007.80136002.06EPA 3491801
7EC36BX-0*+TDR+ furnace: A98USMV070B12AHRI reference: 21478053216.008.10145002.28EPA 3543233
7AH1AE36PX-0*AHRI reference: 21486608316.008.50132002.14EPA 3553691
BCE5V36M*4XAHRI reference: 21117439515.808.10134002.16EPA 2454786
EA(C;U)1P36A+TDR+TXV+ furnace: A80US2V070A12AHRI reference: 21032999815.808.10144002.26EPA 2456327
EA(C;U)1P36A+TDR+TXV+ furnace: A93UH1E045B12AHRI reference: 21033000315.808.10143002.26EPA 2456394
EA(C;U)1P36A+TDR+TXV+ furnace: A80US2V070A12LAHRI reference: 21032999915.808.10144002.26EPA 2456403
BCE7E30M*4XAHRI reference: 21032995915.808.50147002.36EPA 2456535
EAC4X30B+TDR+ furnace: A80UH2E090B12AHRI reference: 21166304715.808.10143002.24EPA 2456816
EA(C;U)1P36B+TDR+TXV+ furnace: A93UH1E030B12AHRI reference: 21166300815.808.10142002.26EPA 2456835
EA(C;U)1P36B+TDR+TXV+ furnace: A93UH1E045B12AHRI reference: 21166300915.808.10143002.26EPA 2456838
EA(C;U)1P36B+TDR+TXV+ furnace: A97US2V060B12XAHRI reference: 21166301815.808.10144002.26EPA 2456845
EAC4X30A+TDR+ furnace: A80UH2E045A12AHRI reference: 21166303915.808.10143002.24EPA 2456849

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →