AIREASE / AIR-SOURCE HEAT PUMP

4SHP17LE130P-**A

4HSP17LE Series · 4SHP17 SERIES · 4SHP17L SERIES · 4SHP17LE SERIES · 4SHP17LE Series · 4SHP17LE1 Series · source records, page 4

333 published source records · source checked Sep 21, 2026

SEER2 range15.2–16.2BTU/Wh
HSPF2 range7.8–8.6BTU/Wh
Cooling capacity28,200–30,600BTU/h

Each efficiency range summarizes published EPA records for 4SHP17LE130P-**A. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 333 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16.2333 / 333
EER2 · BTU/Wh12.2–13.5333 / 333
HSPF2 · BTU/Wh7.8–8.6333 / 333
Cooling capacity · BTU/h28,200–30,600333 / 333
Heating capacity at 47°F / 8.3°C · BTU/h26,600–30,000333 / 333
Heating capacity at 17°F / −8.3°C · BTU/h17,200–19,600333 / 333
Heating capacity at 5°F / −15°C · BTU/h13,200–15,400333 / 333
COP at 5°F / −15°C1.96–2.38333 / 333
Equipment / loop typeHP - Split System333 / 333
Refrigerant / source-reported GWPR-410A (GWP:2088)333 / 333
Compressor stagingSingle stage333 / 333
Connected capabilityNo333 / 333

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
EAC4X30B+TDR+ furnace: A80US2V090B12AHRI reference: 21166306216.008.10143002.20EPA 2459473
EAC4X36B+TDR+ furnace: A93UH1E070B12AHRI reference: 21166308716.008.10144002.28EPA 2459485
EAC4X36B+TDR+ furnace: A80US2V090B16AHRI reference: 21166309316.008.10144002.28EPA 2459490
EAC4X36B+TDR+ furnace: A97US2V040B12XAHRI reference: 21166309416.008.10144002.28EPA 2459501
EAC4X36B+TDR+ furnace: A97USMV070B12AHRI reference: 21166309616.008.10145002.28EPA 2459508
EA(C;U)1P36A+TDR+TXV+ furnace: A80UH1E070A12AHRI reference: 21032999316.008.10144002.28EPA 2459647
BCE7S30M*4XAHRI reference: 21032996016.008.50150002.38EPA 2459664
EAC4X36B+TDR+ furnace: A98USMV070B12AHRI reference: 21380520516.008.10145002.28EPA 2856905
EA(C;U)1P36A+TDR+TXV+ furnace: A98USMV070B12AHRI reference: 21380503916.008.10145002.28EPA 2856921
EA(C;U)1P36B+TDR+TXV+ furnace: A98USMV070B12AHRI reference: 21380520316.008.10145002.28EPA 2857995
EA(C;U)1P36B+TDR+TXV+ furnace: A97US2V070B12SAHRI reference: 21407487716.008.10145002.28EPA 3392065
EAC4X36B+TDR+ furnace: A97US2V070B12SAHRI reference: 21407480416.008.10145002.28EPA 3392081
7EC36BX-0*+TDR+ furnace: A97US2V040B12XAHRI reference: 21471552816.008.10144002.28EPA 3489250
7EC36BX-0*+TDR+ furnace: A97USMV070B12AHRI reference: 21471553016.008.10145002.28EPA 3489270
7EH30BX-0*+TDR+ furnace: A80US2V090B16AHRI reference: 21471542316.008.00137002.08EPA 3489299
7EC36BX-0*+TDR+ furnace: A80US2V090B16AHRI reference: 21471552716.008.10144002.28EPA 3489390
7EC36AX-0*+TDR+ furnace: A80UH2E045A12AHRI reference: 21471550216.008.10143002.28EPA 3489442
7EC36AX-0*+TDR+ furnace: A80UH2E070A12AHRI reference: 21471550316.008.10143002.26EPA 3489444
7EC36AX-0*+TDR+ furnace: A80UH1E045A12AHRI reference: 21471550416.008.10144002.28EPA 3489448
7EC36AX-0*+TDR+ furnace: A80UH1E070A12AHRI reference: 21471550516.008.10144002.28EPA 3489450

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.