AIREASE / AIR-SOURCE HEAT PUMP

4SHP17LE130P-**A

4HSP17LE Series · 4SHP17 SERIES · 4SHP17L SERIES · 4SHP17LE SERIES · 4SHP17LE Series · 4SHP17LE1 Series · source records, page 16

333 published source records · source checked Sep 21, 2026

SEER2 range15.2–16.2BTU/Wh
HSPF2 range7.8–8.6BTU/Wh
Cooling capacity28,200–30,600BTU/h

Each efficiency range summarizes published EPA records for 4SHP17LE130P-**A. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 333 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16.2333 / 333
EER2 · BTU/Wh12.2–13.5333 / 333
HSPF2 · BTU/Wh7.8–8.6333 / 333
Cooling capacity · BTU/h28,200–30,600333 / 333
Heating capacity at 47°F / 8.3°C · BTU/h26,600–30,000333 / 333
Heating capacity at 17°F / −8.3°C · BTU/h17,200–19,600333 / 333
Heating capacity at 5°F / −15°C · BTU/h13,200–15,400333 / 333
COP at 5°F / −15°C1.96–2.38333 / 333
Equipment / loop typeHP - Split System333 / 333
Refrigerant / source-reported GWPR-410A (GWP:2088)333 / 333
Compressor stagingSingle stage333 / 333
Connected capabilityNo333 / 333

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
EAC4X30B+TDR+ furnace: A96UH1E030B12AHRI reference: 21166305815.407.80144002.20EPA 2458085
BCE5V30M*4XAHRI reference: 21032995815.408.10139002.16EPA 2458540
EA(C;U)1P30B+TDR+TXV+ furnace: A96UH1E030B12AHRI reference: 21166299015.407.80144002.20EPA 2458973
EA(C;U)1P30A+TDR+TXV+ furnace: A96UH1E030B12AHRI reference: 21032998215.407.80144002.20EPA 2459648
EAH1P36C*+TDR+TXV+ furnace: A80US2V100C20XAHRI reference: 21173618915.408.50151002.22EPA 2465320
EAD4X-42B+TDR+ furnace: A96DF1E045B12AHRI reference: 21326495515.408.60154002.30EPA 2839855
EA(C;U)1P30B+TDR+TXV+ furnace: A97US2V045B12SAHRI reference: 21407479315.408.00145002.16EPA 3392012
EAC4X30B+TDR+ furnace: A97US2V045B12SAHRI reference: 21407480115.408.00145002.16EPA 3392077
7EH36CX-0*+TDR+ furnace: A80UH1E100C20XAHRI reference: 21471542715.408.30149002.22EPA 3489433
7EC30BX-0*+TDR+ furnace: A96UH1E030B12AHRI reference: 21471549015.407.80144002.20EPA 3489594
7EC30BX-0*+TDR+ furnace: A96UH1E045B12AHRI reference: 21471549115.407.80143002.18EPA 3489596
7EC30BX-0*+TDR+ furnace: A96UH1E070B12AHRI reference: 21471549215.407.80143002.18EPA 3489597
7ED42BX-0*+TDR+ furnace: A96DF1E045B12AHRI reference: 21471546515.408.60154002.30EPA 3489602
7EC30BX-0*+TDR+ furnace: A97US2V045B12S*AHRI reference: 21471548215.408.00145002.16EPA 3489682
7EC30BX-0*+TDR+ furnace: A97UH2E070B12AHRI reference: 21471548315.407.80144002.14EPA 3489683
7EH36CX-0*+TDR+ furnace: A80US2V100C20XAHRI reference: 21471544715.408.50151002.22EPA 3489699
7AH1AV30PX-0*AHRI reference: 21486598815.408.10139002.16EPA 3553683
7AH1AC36PX-0*AHRI reference: 21486601515.408.10136002.14EPA 3553897
BCE5E30M*4XAHRI reference: 21046048315.408.00137002.14EPA 4431923
EA(C;U)1P30A+TDR+TXV+ furnace: A80UH1E080B16XAHRI reference: 21032997215.208.00147002.16EPA 2456371

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →