SEER2 range15.2–16.2BTU/Wh
HSPF2 range7.8–8.6BTU/Wh
Cooling capacity28,200–30,600BTU/h

Each efficiency range summarizes published EPA records for 4SHP17LE130P-**A. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 333 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16.2333 / 333
EER2 · BTU/Wh12.2–13.5333 / 333
HSPF2 · BTU/Wh7.8–8.6333 / 333
Cooling capacity · BTU/h28,200–30,600333 / 333
Heating capacity at 47°F / 8.3°C · BTU/h26,600–30,000333 / 333
Heating capacity at 17°F / −8.3°C · BTU/h17,200–19,600333 / 333
Heating capacity at 5°F / −15°C · BTU/h13,200–15,400333 / 333
COP at 5°F / −15°C1.96–2.38333 / 333
Equipment / loop typeHP - Split System333 / 333
Refrigerant / source-reported GWPR-410A (GWP:2088)333 / 333
Compressor stagingSingle stage333 / 333
Connected capabilityNo333 / 333

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
7EC36BX-0*+TDR+ furnace: A96UH1E030B12AHRI reference: 21471552215.608.00143002.24EPA 3489731
7EC36BX-0*+TDR+ furnace: A96UH1E070B12AHRI reference: 21471552415.608.10143002.26EPA 3489732
7EC30BX-0*+TDR+ furnace: A80US2V090B16AHRI reference: 21471549515.608.10145002.18EPA 3489796
7EC30BX-0*+TDR+ furnace: A97US2V040B12XAHRI reference: 21471549615.608.00145002.20EPA 3489797
7EC30BX-0*+TDR+ furnace: A97US2V060B12XAHRI reference: 21471549715.608.00145002.20EPA 3489798
7EC30BX-0*+TDR+ furnace: A97USMV070B12AHRI reference: 21471549815.608.00145002.18EPA 3489799
7EC36BX-0*+TDR+ furnace: A80UH1E080B16XAHRI reference: 21471551015.608.10146002.24EPA 3489820
7EC36BX-0*+TDR+ furnace: A96UH1E045B12AHRI reference: 21471552315.608.10146002.26EPA 3491684
7EC36BX-0*+TDR+ furnace: A97US2V045B12S*AHRI reference: 21471551415.608.10145002.26EPA 3491896
7EH36CX-0*+TDR+ furnace: A98USMV090C12AHRI reference: 21478052715.608.30147002.22EPA 3543173
7EH36CX-0*+TDR+ furnace: A98USMV090C16AHRI reference: 21478052815.608.30144002.22EPA 3543174
7EC30BX-0*+TDR+ furnace: A98USMV070B12AHRI reference: 21478053115.608.00145002.18EPA 3543232
7AH2AE36PX-0*AHRI reference: 21486606415.508.50149002.36EPA 3553819
BCE5C36M*4XAHRI reference: 21117438615.408.10136002.14EPA 2454777
EA(C;U)1P30A+TDR+TXV+ furnace: A96UH1E045B12AHRI reference: 21032997515.407.80143002.18EPA 2456544
EA(C;U)1P30B+TDR+TXV+ furnace: A96UH1E045B12AHRI reference: 21166299115.407.80143002.18EPA 2456780
EA(C;U)1P30B+TDR+TXV+ furnace: A96UH1E070B12AHRI reference: 21166299215.407.80143002.18EPA 2456781
EA(C;U)1P30A+TDR+TXV+ furnace: A96UH1E070B12AHRI reference: 21032997615.407.80143002.18EPA 2457055
EAC4X30B+TDR+ furnace: A96UH1E045B12AHRI reference: 21166305915.407.80143002.18EPA 2458083
EAC4X30B+TDR+ furnace: A96UH1E070B12AHRI reference: 21166306015.407.80143002.18EPA 2458084

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →